Aims
Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management and outcome are sparse.
Methods and results
This international multicenter registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553,729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed at 214 centers in 35 countries. In 78 centers 138 patients (0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (p<0.0001)) were diagnosed with an oesophageal fistula. Periprocedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8%, and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) (odds ratio 7.463 (2.414, 23.072) p<0.001).
Conclusions
Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high.
Background
Luminal esophageal temperature (LET) monitoring is not associated with reduced esophageal injury following pulmonary vein isolation (PVI).
Objective
Detailed analysis of (the temporal and spatial gradients of) LET measurements may better predict the risk for esophageal injury.
Methods
Between January 2020 and December 2021, LET maxima, duration of LET rise above baseline, and area under the LET curve (AUC) were calculated offline and correlated with (endoscopy and endoscopic ultrasound detected) esophageal injury (i.e., mucosal esophageal lesions [ELs], periesophageal edema, and gastric motility disorders) following PVI using moderate‐power moderate‐duration (MPMD [25–30 W/25–30s]) and high‐power short‐duration (HPSD [50 W/13s]) radiofrequency (RF) settings.
Results
63 patients (69 ± 9 years old, 32 male, 51 MPMD and 12 HPSD) were studied. The esophageal injury was frequent (40% in both groups), mucosal ELs were more common with MPMD, and edema was frequently observed following HPSD. RF‐duration, total RF‐energy at the left atrial (LA) posterior wall, and distance between LA and esophagus were not different between patients with/without esophageal injury. In contrast, to LET and LET duration above baseline, AUC was the best predictor and significantly increased in patients with esophageal injury (3422 vs. 2444 K.s).
Conclusion
For both ablation strategies, AUC of the LET curves best predicted esophageal injury. HPSD is associated with similar rates of esophageal injury when (mostly subclinical) periesophageal alterations (that are of unclear clinical relevance) are included. Whether integration of these calculated LET parameters is useful to prevent esophageal injury remains to be seen.
Introduction
Safety of pulmonary vein isolation (PVI) has been established in clinical studies. However, despite prevention efforts the incidence of damage to (peri)‐esophageal tissue has not decreased, and the pathophysiology is incompletely understood. Damage to vagal nerve branches may be involved in lesion progression to atrio‐esophageal fistula. Using electrogastrography, we assessed the incidence of periesophageal vagal nerve injury (VNI) following atrial fibrillation ablation and its association with procedural parameters and endoscopic results.
Methods
Patients were studied using electrogastrography, endoscopy, and endoscopic ultrasound before and after cryoballoon (CB) or radiofrequency (RF) PVI. The incidence of ablation‐induced neuropathic pattern (indicating VNI) in pre‐ and postprocedural electrogastrography was assessed and correlated with endoscopic results and ablation data.
Results
Between February 2021 und January 2022, 85 patients (67 ± 10 years, 53% male) were included, 33 were treated with CB and 52 with RF (38 with moderate power moderate duration [25–30 W] and 14 with high power short duration [50 W]). Ablation‐induced VNI was detected in 27/85 patients independent of the energy form. Patients with VNI more frequently had postprocedural endoscopically detected pathology (8% mucosal esophageal lesions, 36% periesophageal edema, 33% food retention) but there was incomplete overlap. Pre‐existing esophagitis increased the likelihood of VNI. Ablation data and esophageal temperature data did not predict VNI.
Conclusion
PVI‐induced VNI is quite common and independent of ablation energy source. VNI is part of (peri)‐esophageal damage and only partially overlaps with endoscopic findings. VNI‐associated acidic reflux may be involved in the complex pathophysiology of esophageal lesion progression to fistula.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.