Background
There is global shortage of Personal Protective Equipment due to COVID-19 pandemic. N95 Filtering Facepiece Respirators (N95-FFRs) provide respiratory protection against respiratory pathogens including SARS-CoV-2. There is scant literature on reprocessing methods which can enable reuse of N95-FFRs.
Aim
We conducted this study to evaluate research done, prior to COVID-19 pandemic, on various decontamination methods for reprocessing of N95-FFRs.
Methods
We searched 5 electronic databases (Pubmed, Google Scholar, Crossref, Ovid, ScienceDirect) and 1 Grey literature database (OpenGrey). We included original studies, published prior to year 2020, which had evaluated any decontamination method on FFRs. Studies had evaluated a reprocessing method against parameters namely physical changes, user acceptability, respirator fit, filter efficiency, microbicidal efficacy and presence of chemical residues post-reprocessing.
Findings and conclusions
Overall, we found 7887 records amongst which 17 original research articles were finally included for qualitative analysis. Overall, 21 different types of decontamination or reprocessing methods for N95-FFRs were evaluated. Most commonly evaluated method for reprocessing of FFRs was Ultraviolet (Type-C) irradiation (UVGI) which was evaluated in 13/17 (76%) studies. We found published literature was scant on this topic despite warning signs of pandemic of a respiratory illness over the years. Promising technologies requiring expeditious evaluation are UVGI, Microwave generated steam (MGS) and based on Hydrogen peroxide vapor. Global presence of technologies, which have been given Emergency use authorisation for N95-FFR reprocessing, is extremely limited. Reprocessing of N95-FFRs by MGS should be considered for emergency implementation in resource limited settings to tackle shortage of N95-FFRs.
Systematic review identifier
PROSPERO, PROSPERO ID: CRD42020189684, (https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42020189684).
Real-time reverse transcription- polymerase chain reaction (RT-PCR) has been the most reliable armoury for the diagnosis of COVID-19, considered to be the reference standard but fails to reproduce the correct predictability about the infectivity of the disease every time. Antigen detection however puts foothold in this aspect even though lacks in sensitivity, especially conventional Rapid Antigen Tests (RATs). Recently developed Chemiluminescence Immunoassay (CLIA) based antigen detection tests are promising and displayed better sensitivity. In the current study we have evaluated VITROS® SARS-CoV-2 Ag Test CLIA Kit, which was tested on 148 patient’s samples attended to a tertiary care centre for testing of SARS-CoV-2. The performance of the kit was evaluated in comparison to RT-PCR and RAT and found to be a good test for antigen detection, best within the first few days of infection. The test has shown sensitivity of 94.3 % and specificity of 100 % in samples with corresponding Ct values of ≤25 by RT-PCR, which corresponds to high viral load and can predict ability of spreading the disease by the patients. With the results being semiquantitative along with improved sensitivity it can replace RATs for antigen detection for screening, provided good laboratory set up is included under consideration.
Genome surveillance of the Delhi data provides a more detailed picture of diverse circulating lineages. The added value that the current study provides by clinical details of the patients is of importance.
Background: There is global shortage of Personal Protective Equipment due to COVID-19 pandemic. N95 Filtering Facepiece Respirators (N95-FFRs) provide respiratory protection against respiratory pathogens including SARS-COV-2. There is scant literature on reprocessing methods which can enable reuse of N95-FFRs.
Aim: We conducted this study to evaluate research done, prior to COVID-19 pandemic, on various decontamination methods for reprocessing of N95-FFRs.
Methods: We searched 5 electronic databases (Pubmed, Google Scholar, Crossref, Ovid, ScienceDirect) and 1 Grey literature database (OpenGrey). We included original studies, published prior to year 2020, which had evaluated any decontamination method on FFRs. Studies had evaluated a reprocessing method against parameters namely physical changes, user acceptability, respirator fit, filter efficiency, microbicidal efficacy and presence of chemical residues post-reprocessing.
Findings and Conclusions: Overall, we found 7887 records amongst which 17 original research articles were finally included for qualitative analysis. Overall, 21 different types of decontamination or reprocessing methods for N95-FFRs were evaluated. Most commonly evaluated method for reprocessing of FFRs was Ultraviolet (Type-C) irradiation (UVGI) which was evaluated in 13/17 (76%) studies.
We found published literature is scant on this topic despite warning signs of pandemic of a respiratory illness over the years. Promising technologies requiring expeditious evaluation are UVGI, Microwave generated steam (MGS) and Hydrogen peroxide vapor (HPV). Global presence of technologies, which have been given Emergency use authorisation for N95-FFR reprocessing, is extremely limited. Reprocessing of N95-FFRs by MGS should be considered for emergency implementation in resource limited settings to tackle shortage of N95-FFRs.
The QIAstat-Dx SARS-CoV-2 panel is a multiplex cartridge based assay based on real time PCR which can detect 17 respiratory viruses, including the novel coronavirus SARS-CoV-2. A syndromic approach is the need of the hour for COVID-19 diagnostics among patients presenting with respiratory symptoms. The present study was done to evaluate 120 archived respiratory clinical specimens for SARS-CoV-2 on the SARS-CoV-2 panel. Further, 27 specimens were tested for other respiratory viruses, in comparison with the BioFire RP1.7 platform. The sensitivity and specificity for SARS-CoV-2 on SARS panel was found to be 90.00% and 100% respectively, indicating good diagnostic accuracy. The positive predictive value was found to be 100%, negative predictive value was found to be 99.93% and accuracy was 99.93%. Detection of other respiratory viruses observed a concordance of 77.7%. Despite advantages of speed, minimal expertise and accurate results; significant costs and discrepancies at Ct >35 remain important limitations of the SARS panel.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.