Purpose: Direct anterior approach total hip arthroplasty (DA THA) has been reported to improve early outcomes compared to posterior approach THA up to 6 weeks postoperatively. Limited weekly outcomes data are available prior to 6 weeks. We evaluate outcomes including when patients first drive a car, leave home, and discontinue their assist device. Methods: Patients undergoing THA for primary osteoarthritis were prospectively enrolled. Outcomes data were collected preoperatively and postoperatively at weekly intervals for 6 weeks. Results: 111 patients (55 DA and 56 posterior approach) were enrolled. There was no significant difference ( p > 0.05) in pre-surgical Patient-Reported Outcomes Measurement Information System (PROMIS) scores or modified Harris Hip Score (mHHS). Postoperatively, the DA THA group had decreased length of stay ( p = 0.0002) and increased distance walked on postoperative day 1 and 2 ( p = 0.011, p = 0.0004). The DA group had lower pain scores ( p < 0.05) and required less day 1 and total narcotics ( p = 0.029, p = 0.01). The DA cohort had improved PROMIS Physical Function scores and mHHS up to 5 weeks postoperatively. DA patients discontinued their assistive device 8 days earlier ( p = 0.01), left home 3 days earlier ( p = 0.001), and drove a car 5 days earlier ( p = 0.01). Conclusions: Patients undergoing DA THA discontinued their assistive device, left their home, and drove a car sooner than posterior approach patients. We found improvement in physical function with DA, and it persisted up to 5 weeks postoperatively. Furthermore, DA patients had significantly shorter length of stay, improved mobilisation, decreased narcotic requirements and improved inpatient pain scores compared to posterior approach THA. Future randomised controlled study should be performed to minimise the biases inherent in this study methodology and confirm the results.
The modified Harris Hip Score (mHHS) is a validated and disease-specific instrument commonly used to assess outcomes in total hip arthroplasty (THA). The Patient-Reported Outcomes Measurement Information System (PROMIS) is a validated, computer adaptive testing (CAT)–based global health assessment tool. The authors' goal was to examine the correlation between PROMIS Pain Interference and Physical Function CATs and the mHHS in patients undergoing primary THA. All THAs were performed by 1 of 2 fellowship-trained dedicated total joint surgeons at 1 academic institution. Patients completed PROMIS and mHHS assessments preoperatively and at 3, 6, 12, and 52 weeks postoperatively. Descriptive statistics and Pearson correlation values were determined. A total of 48 patients were prospectively enrolled in the study. Preoperatively, mean total PROMIS score (Pain Interference and Physical Function) was 74.2 and mHHS was 50.8. Preoperatively, mean total PROMIS score showed a moderate correlation ( r =0.56; P <.0001) with total mHHS. Postoperatively, mean total PROMIS score at 3, 6, 12, and 52 weeks was 82.4, 93.4, 100, and 100, respectively (all P <.01 vs baseline), and mHHS was 68.2, 81.1, 85.9, and 88.6, respectively (all P <.01). At 3, 6, 12, and 52 weeks postoperatively, a strong and consistent correlation was observed between the total PROMIS score and mHHS ( r =0.74, 0.74, 0.73, and 0.80, respectively; all P <.0001). The PROMIS Pain Interference and Physical Function CATs accurately assessed preoperative pain and dysfunction, as well as clinical improvement following THA. Combined PROMIS Pain Interference and Physical Function is comparable to the mHHS when assessing outcome following THA for osteoarthritis. [ Orthopedics . 2021;44(1):e19–e25.]
Modern total knee arthroplasty is effective at treating the pain and disability associated with osteoarthritis. The number of total knee replacements done in the USA continues to increase. Despite the great care taken during all of these procedures, some patients remain dissatisfied with their outcome. While this dissatisfaction is likely multifactorial, malalignment of the prosthetic components is a major cause of postoperative complications. A neutral mechanical axis plus or minus 3° is felt to have a positive impact on the survivorship of the prosthesis. Conventional instrumentation has been shown to have a significant number of total knee replacements that lie well outside a neutral coronal alignment. With that in mind, significant effort has been placed into the development of technology to improve the overall alignment of the prosthesis. In order to reduce the number of outliers, several companies have developed cost-effective systems to aid the surgeon in achieving a more predictably aligned prosthesis in all three planes. We will review the literature that is available regarding several of these tools to examine if navigation or custom guides improve outcomes in total knee arthroplasty. Our review supports that while both navigation and custom implants guides seem to be a cost effective way to achieve a predictable mechanical alignment of a total knee prosthesis therefore reducing the number of outliers, the cost may be increased operative times with no perceived difference in patient satisfaction with navigation custom guides.
Interprosthetic femur fractures are a rare but serious complication following total hip and knee arthroplasty. Classification systems have focused not only on diagnosis but also on treatment algorithm. Critical to the evaluation of patients with these fractures are an assessment of fracture location, bone quality, and the presence of stemmed implants. The gold standard for fracture fixation is locked plating with bicortical and unicortical screws, supplemented with wires or cables as needed. For patients with compromised bone stock or insufficient bony area for fixation, allograft augmentation with struts or interprosthetic sleeves may be used. For fractures with severe bone loss, conversion to a megaprosthesis or total femur replacement may be warranted.
Introduction: Intraoperative radiographic evaluation during total hip arthroplasty (THA) has shown to improve the accuracy of acetabular component placement, however, differences in interpretation based on radiographic technique has not been established. This study aims to determine if differences exist in the interpretation of acetabular component abduction and anteversion between different radiographic projections. Methods: 55 consecutive direct anterior THAs in 49 patients were prospectively enrolled. Target anteversion and abduction was defined by the Lewinnek zone. Fluoroscopy was used to direct acetabular component placement intraoperatively. After final cup implantation, fluoroscopic posterior-anterior hip and pelvis images were obtained for analysis. After completion of the procedure, an anterior-posterior plain pelvis radiograph was obtained in the operating room. Acetabulum component abduction and anteversion were postoperatively determined using specialised software on each of the 3 image acquisition methods. Results: Average acetabular cup abduction for intraoperative fluoroscopic posterior-anterior hip (FH), intraoperative fluoroscopic posterior-anterior pelvis (FP), and postoperative, standard, anteroposterior pelvis radiographs (PP) was 40.95° ± 2.87°, 38.87° ± 3.82° and 41.73° ± 2.96° respectively. The fluoroscopic hip and fluoroscopic pelvis tended to underestimate acetabular cup abduction compared to the postoperative pelvis ( p < 0.001). Average acetabular cup anteversion for FH, FP, and PP was 19.89° ± 4.87°, 24.38° ± 5.31° and 13.36° ± 3.52° respectively. Both the fluoroscopic hip and fluoroscopic pelvis overestimated anteversion compared to the AP pelvis, with a 6.38° greater mean value measurement for FH ( p < 0.001), and an 11° greater mean value measurement for FP ( p < 0.001). Conclusions: Fluoroscopic technique and differences between radiographic projections may result in discrepancies in component position interpretation. Our results support the use of the fluoroscopic posterior-anterior hip as the choice fluoroscopic imaging technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.