Nodal status is one of the most important prognostic factors in breast cancer. Established tests such as touch imprint cytology and frozen sections currently used in the intra-operative setting show variations in sensitivity and specificity. This limitation has led to the development of molecular alternatives, such as GeneSearch, a commercial intra-operative real-time quantitative Polymerase Chain Reaction (RT-qPCR) assay that allows the surgeon to carry out axillary clearance as a one-step process. Since GeneSearch has been discontinued, we have developed the replacement Metasin assay, which targets the breast epithelial cell markers CK19 and mammaglobin mRNA and identifies metastatic disease in sentinel lymph nodes. The optimised assay can be completed within 32 min (6 min for RNA preparation and 26 min instrument run time), making its use feasible in the intraoperative setting. An analysis by Metasin of 154 archived lymph node homogenates previously analysed by both parallel histology and GeneSearch showed concordance for 148 cases. The sensitivity and specificity of Metasin compared with GeneSearch were 95% (CI 83%–99%) and 97% (CI 91%–99%) respectively; compared with histology they were 95% (CI 83%–99%) and 97% (CI 91%–99%), respectively. The sensitivity and specificity of GeneSearch compared with histology were 90% (CI 77%–96%) and 97% (CI 93%–99%) respectively. The positive predictive value of Metasin was 90% and negative predictive value was 98% for both histology and GeneSearch. The positive predictive value of GeneSearch was 92% and the negative predictive value was 97% compared to histology. The discordance rates of Metasin with both GeneSearch and histology were 3.89%. In comparison, the discordance rate of GeneSearch with histology was 4.5%. Metasin’s robustness was independently evaluated on 193 samples previously analysed by GeneSearch from the Jules Bordet Institute, where Metasin yielded comparable results.
The pathologist forms a very important part of the clinical team in the management of pediatric intra-abdominal masses in giving a rapid, accurate diagnosis for these potentially curable tumors. Fine-needle aspiration cytology (FNAC) is an invaluable tool in this regard when interpreted with clinicoradiologic parameters. With this in mind, we decided to evaluate the role of FNAC in pediatric abdominal masses in our institution. A total of 83 of 105 FNAC accessioned in the pathology department over 5 years (2003-2007) were studied. These included only cases where a diagnosis could be offered on cytology. Detailed clinicoradiological features were obtained from hospital records. Cytomorphological features examined included cellularity, architectural pattern, background, key cellular details. Immunocytochemistry were done where necessary. Lesions diagnosed on FNAC included Wilms' tumor (19), lymphoma (10), neuroblastoma (6), hepatoblastoma (5), PNET (5), rhabdomyosarcoma (2), DSRCT (2), germ cell tumor (6), and miscellaneous tumors (7). Definite diagnosis could be offered on cytomorphology in 74.7% (62) cases, while in 25.3% (21) cases only a diagnosis of round cell tumor could be offered. Concordance with final histopathology and biochemical parameters was subsequently obtained in 79/83 (95.5%) of cases. A clinically relevant classification is possible on FNAC in pediatric abdominal tumors when interpreted with clinicoradiologic parameters. This obviates the need for a more time-consuming biopsy procedure in critical situations and in stage II nephroblastoma where it is contraindicated.
Aims: Treatment strategies for breast cancer continue to evolve. No uniformity exists in the UK for the management of node-positive breast cancer patients. Most centres continue to use conventional histopathology of sampled sentinel lymph nodes (SLNs), which requires delayed axillary clearance in up to 25% of patients. Some use touch imprint cytology or frozen section for intraoperative testing, although both have inherent sensitivity issues. An intraoperative molecular diagnostic approach helps to overcome some of these limitations. The aim of this study was to assess the clinical effectiveness of Metasin, a molecular method for the intraoperative evaluation of SLNs. Methods and results: RNA from 3296 lymph nodes from 1836 patients undergoing SLN assessment was analysed with Metasin. Alternate slices of tissue were examined in parallel by histology. Cases deemed to be discordant were analysed by protein gel electrophoresis. There was concordance between Metasin and histology in 94.1% of cases, with a sensitivity of 92% [95% confidence interval (CI) 88-94%] and a specificity of 97% (95% CI 2016 , 68, 875-887. DOI: 10.1111 95-97%). Positive and negative predictive values were 88% and 98%, respectively. Over half of the discordant cases (4.4%) were ascribed to tissue allocation bias (TAB).Conclusions: Clinical validation of the Metasin assay suggests that it is sufficiently sensitive and specific to make it fit for purpose in the intraoperative setting.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.