This paper proposes a new Search Group Algorithm based PID controller, to deal with Automatic Generation Control of two-area with six unit power system. The supremacy of SGA tuned PID controller is being shown using the comparative study with Firefly Algorithm (FA) optimization method for the same test system using ITAE as an objective function. It has been demonstrated that SGA tuned PID controller improves the performance in a large compared with FA tuned PID controller. Furthermore variation in nominal values of operating load condition and system parameters with the position of step load perturbation is being carried out to achieve sensitivity analysis. From the result of sensitivity analysis it clearly depicts the robustness of the suggested method (SGA with PID controller) for two-area with six unit power system in AGC. Finally for better investigation, the proposed method is also examined by applying randomization in step load.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.