The aim of this study was to retrospectively evaluate the frequency of femur fractures in dogs and cats in the routine of a school hospital, determining their classification, fixation methods, complications, and outcomes. A total of 61 animals, 50 (82.0%) dogs and 11 (18.0%) cats, had femoral fractures that were submitted to osteosynthesis. Sixty-two femoral fractures were evaluated. Single fractures in the distal epiphysis (n=25) were the most frequent (P=0.0001). Intramedullary pins were used in association with cerclage and tension band for osteosynthesis in proximal fractures. In diaphyseal fractures, bone plates and screws, two intramedullary pins (insulated or with cerclage) and Tie-In configuration were used. In distal fractures, modified Rush intramedullary pins, cross pins and Tie-In configuration were used. Comparing complication frequencies at fracture sites that required reintervention after osteosynthesis, a significant difference was observed (P=0.0253) between the diaphyseal (31.25%) and distal (7.14%) fractures independent of the technique used. We concluded that distal epiphyseal fractures were the most frequent in the routine of a school hospital. Distal epiphyseal fractures presented a lower frequency of complications for consolidation when treated with modified Rush intramedullary pins or crossed pins.
Full paper Wildlife Science Running head: OVARIOSALPINGECTOMY WITH DIGITAL OTOSCOPE Coelioscopic-assisted prefemoral ovariosalpingectomy in a d`Orbigny slider (Trachemys dorbigni) using a digital otoscope
The purpose of this study was to assess the use of a homemade multiport for LESS (laparoendoscopic single-site surgery) ovariohysterectomy (OVH) in cats. Intra and postoperative variables of the surgery steps, technical challenges, complications and evolution of surgical time by a surgeon in training were evaluated. Twenty queens were selected for LESS OVH. The multiport device was manufactured of a conical-shaped ethylene polytereftalate (PET) bottle, urethral catheter no. 8, latex balloon no. 11, a 3.5mm and a 6mm laparoscopic trocars. Hemostasis was carried out using bipolar diathermy. Mean total surgical time was 14.54±5.12 minutes. Approach to right and left ovarian pedicles and abdominal access for insertion of the multiport device were the most time consuming surgical steps. LESS ovariohysterectomy using a new homemade multiport device is feasible and safe. Thus, the proposed technique may be considered as a minimally invasive alternative to ovariohysterectomy in the feline specie.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.