This study evaluated the energy saving potential of renewable energy generation systems based on integrated solar energy in an urban environment. The solar city concept was implemented using photovoltaic (PV) and solar thermal systems. As a case study, the Sejong national pilot smart city in South Korea was selected to evaluate the renewable energy penetration rate. For evaluating the proposed renewable energy systems, the electrical and thermal loads of the smart city were estimated using field measurement data. Then, the renewable energy penetration rate of the city was evaluated. The HomerPro software was used to analyze the PV generation and operating energy consumption of the natural gas (NG) generator with a district heating network. The thermal load-supporting potential of the solar thermal system was estimated using the TRNSYS software. The results showed that the proposed urban integrated renewable energy system could meet over 30% of the renewable energy penetration rate and the levelized cost of energy and total net present cost was 7% lower than the base case system (i.e., NG generator). The proposed system also exhibited 38% less CO2 emissions than the base case system.
District cooling and heating methods that can utilize highly efficient heat pumps and various unused new and renewable types of energy are required to achieve low carbon emissions and zero energy usage in buildings and community units. The technical requirements for the implementation of decentralized thermal networks and heat trading are increasing, both for thermal networks in new buildings and for those remodeled based on existing centralized thermal networks. In this study, a conventional centralized thermal network was implemented as a decentralized thermal network and the possibility of heat prosumers feeding thermal networks was demonstrated experimentally. A real-scale plant was constructed by employing unused thermal energy facilities as prosumers in a school and childcare center based on the existing small-scale block heating and cooling thermal network. The decentralized thermal network and heat prosumer concepts were proven through operation experiments performed on the constructed system in summer and winter. An economic benefit can be achieved by increasing the peak power cost. The experimental results also showed that the proposed bi-directional heat trading reduced carbon emissions by 12.7% compared with conventional centralized thermal systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.