Background: For patients with borderline annulus areas that fall between two valve sizes, overinflating a smaller balloon-expandable transcatheter heart valve (THV) may be preferable to nominal sizing of a larger THV.Objectives: To evaluate the outcomes of nominal preparation versus over-expanding an under-sized SAPIEN 3 Ultra (S3U) transcatheter heart valve (OE-THV) in cases with borderline annuli.Methods: 958 patients that underwent TAVR with the S3U at four high-volume TAVR centers between January 2017 and December 2020 were retrospectively reviewed. 336 patients were identified as borderline annuli size, of which 146 (44%) received OE-THVs and 190 (56%) received nominal-sized THVs. The primary composite endpoint included: in-hospital mortality, aortic injury, moderate/severe paravalvular leak (PVL), permanent pacemaker implant (PPM), stroke, or conversion to surgery.Results: Baseline characteristics were similar except for a larger percentage of females in the OE-THV (53.42% vs. 42.11%, p = 0.04). TAVR with OE-THV resulted a reduction in the primary composite endpoint (13.69% vs. 22.63%, p = 0.04). On subgroup analysis, there was no difference between 20 mm OE-THV versus 23 mm nominal or 23 mm OE-THV versus 26 mm nominal, but there was a reduction in the
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.