Purpose-To compare the measurements of visual acuity (VA) results measured with Snellen and Early Treatment Diabetic Retinopathy Study (ETDRS) charts in eyes with and without age-related macular degeneration (AMD). Design-Cross-sectional study. Participants-One hundred four participants (190 eyes) selected from a university retina practice; 80 participants (142 eyes) had some degree of AMD. Methods-Visual acuity was measured in each patient using standard procedure with both snellen and ETDRS charts in random order. Statistical analysis of the results was performed. Main Outcome Measures-Difference in VA measured by both charts in logarithm of minimal angle of resolution (logMAR) notations. Results-Overall, the mean Snellen VA was 0.78 logMAR (= 20/120), and the mean ETDRS VA in the same eye was 0.54 logMAR (= 20/70; P<0.001). In the low vision group (<20/200), represented by patients with AMD, the average difference in number of lines was considerably larger than in the good vision range (>20/30). On average, 20/200 on Snellen was 20/95 on ETDRS (>3 lines difference), and 20/30 on Snellen was 20/25 on ETDRS (<1 line difference). Conclusion-Our results show poor agreement between the Snellen and ETDRS charts, and it was more pronounced in the group with poor vision. The ETDRS measurements yielded better VA, particularly in participants with vision <20/200 (representing more advanced AMD patients). We suggest taking these findings into consideration when comparing outcomes in clinical practices (which typically measure VA using standard Snellen charts) with outcomes from clinical trials (which typically measure VA using ETDRS charts). Visual acuity (VA) in clinical settings is an ability to discriminate two stimuli separated in space at high contrast compared with the background. This simple measure detects most of the
Purpose To identify factors associated with best-corrected visual acuity (BCVA) presentation and two-year outcome in 479 intermediate, posterior, and panuveitic eyes. Design Cohort study using randomized controlled trial data Methods Multicenter Uveitis Steroid Treatment (MUST) Trial masked BCVA measurements at baseline and 2 years’ follow-up used gold standard methods. Twenty-three clinical centers documented characteristics per protocol, which were evaluated as potential predictive factors for baseline BCVA and two-year change in BCVA. Results Baseline factors significantly associated with reduced BCVA included: age ≥50 vs. <50 years; posterior vs. intermediate uveitis; uveitis duration >10 vs. <6 years; anterior chamber (AC) flare > grade 0; cataract; macular thickening; and exudative retinal detachment. Over two years, eyes better than 20/50 and 20/50 or worse at baseline improved, on average, by 1 letter (p=0.52) and 10 letters (p<0.001) respectively. Both treatment groups and all sites of uveitis improved similarly. Factors associated with improved BCVA included resolution of active AC cells, of macular thickening, and cataract surgery in an initially cataractous eye. Factors associated with worsening BCVA included longer duration of uveitis (6–10 or >10 vs. <6 years), incident AC flare, cataract at both baseline and follow-up, pseudophakia at baseline, persistence or incidence of vitreous haze, and incidence of macular thickening. Conclusions Intermediate, posterior and panuveitis have a similarly favorable prognosis with both systemic and fluocinolone acetonide implant treatment. Eyes with more prolonged/severe inflammatory damage and/or inflammatory findings initially or during follow-up have a worse visual acuity prognosis. The results indicate the value of implementing best practices in managing inflammation.
Purpose To describe fluocinolone acetonide implant dissociations in the Multicenter Uveitis Steroid Treatment (MUST) Trial. Design Randomized clinical trial with extended follow-up. Methods Review of data collected on the first implant in the eye(s) of participants. Dissociation was defined as the drug pellet no longer being affixed to the strut and categorized as spontaneous or surgically-related. Results 250 eyes (146 patients) had at least one implant placed. Median time follow-up time after implant placement was 6 years (range 0.5 to 9.2). Thirty-four dissociations were reported in 30 participants. There were 22 spontaneous events in 22 participants; 6-year cumulative risk of a spontaneous dissociation was 4.8% (95% confidence interval (CI): 2.4%–9.1%). The earliest event occurred 4.8 years after placement. Nine of 22 eyes with data had a decline in visual acuity ≥5 letters temporally related to the dissociation. 39 implant removal surgeries were performed, 33 with replacement. Twelve dissociations were noted during implant removal surgeries in 10 participants (26%, 95% CI 15%–48%); 5 of these eyes had a decline in visual acuity ≥5 letters after surgery. The time from implant placement to removal surgery was longer for the surgeries at which dissociated implants were identified than for those without one (5.7 vs 3.7 years, p < 0.001). Overall, visual acuity declined 15 or more letters from pre-implant values in 22% of affected eyes; declines were frequently associated with complications of uveitis or it’s treatment. Conclusion There is an increasing risk of dissociation of Retisert implants during follow-up, the risk is greater with removal/exchange surgeries, but both the risk of spontaneous and surgically related events increase with longevity of the implants. In 22% of affected eyes visual acuity declined by 15 letters. In the context of eyes with moderate to severe uveitis for years, this rate is not unexpected.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.