Purpose This study evaluates the Argus™ II Retinal Prosthesis System in blind subjects with severe outer retinal degeneration. Design The study design is a single arm, prospective, multicenter clinical trial. Participants Thirty subjects were enrolled in the United States and Europe between 6 June 2007 and 11 August 2009. All subjects were followed for a minimum of six months and up to 2.7 years. Methods The electronic stimulator and antenna of the implant was sutured onto the sclera using an encircling silicone band. Next, a pars plana vitrectomy was performed and the electrode array and cable were introduced into the eye via a pars plana sclerotomy. The microelectrode array was then tacked to the epiretinal surface. Main Outcome Measures The primary safety endpoint for the trial was the number, severity, and relation of adverse events. Principal performance endpoints were assessments of visual function as well as performance on orientation and mobility tasks. Results Subjects performed statistically better with system ON vs. OFF in the following tasks: object localization (96% of subjects); motion discrimination (57%); and discrimination of oriented gratings (23%). The best recorded visual acuity to date is 20/1260. Subjects’ mean performance on Orientation and Mobility tasks was significantly better when the System was ON vs. OFF. Seventy percent of the patients did not have any serious adverse events (SAEs). The most common SAE reported was either conjunctival erosion or dehiscence over the extraocular implant and was successfully treated in all subjects except in one which required explantation of the device without further complications. Conclusions The long-term safety results of Second Sight’s retinal prosthesis system are acceptable and the majority of subjects with profound visual loss perform better on visual tasks with system than without.
Purpose The Argus® II Retinal Prosthesis System (Second Sight Medical Products, Inc., Sylmar, CA) was developed to restore some vision to patients blind from retinitis pigmentosa (RP) or outer retinal degeneration. A clinical trial was initiated in 2006 to study the long-term safety and efficacy of the Argus II System in patients with bare or no light perception due to end-stage RP. Design The study is a prospective, multicenter, single-arm, clinical trial. Within-patient controls included the non-implanted fellow eye and patients' native residual vision compared to their vision when using the System. Subjects There were 30 subjects in 10 centers in the U.S. and Europe. Methods The worse-seeing eye of blind patients was implanted with the Argus II System. Patients wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina. Main Outcome Measures The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by three computer-based, objective tests. Secondary measures included functional vision performance on objectively-scored real-world tasks. Results Twenty-four out of 30 patients remained implanted with functioning Argus II Systems at 5 years post-implant. Only one additional serious adverse event was experienced since the 3-year time point. Patients performed significantly better with the System ON than OFF on all visual function tests and functional vision tasks. Conclusions The five-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind from RP. The Argus II is the first and only retinal implant to have market approval in the European Economic Area, the United States, and Canada.
Purpose Retinitis Pigmentosa (RP) is a group of inherited retinal degenerations leading to blindness due to photoreceptor loss. A rare disease, it affects about 100,000 people in the United States. There is no cure and no approved medical therapy to slow or reverse RP. The purpose of this clinical trial was to evaluate the safety, reliability, and benefit of the Argus® II Retinal Prosthesis System (Second Sight Medical Products, Inc., Sylmar, CA) in restoring some visual function to subjects completely blind from RP. Herein, we report clinical trial results at 1 and 3 years post-implant. Design The study is a multicenter, single-arm, prospective clinical trial. Subjects There were 30 subjects in 10 centers in the U.S. and Europe. Subjects served as their own controls – i.e., implanted eye vs. fellow eye, and System ON vs. System OFF (native residual vision). Methods The Argus II System was implanted on and in a single eye (typically the worse-seeing eye) of blind subjects. Subjects wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina. Main Outcome Measures The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by three computer-based, objective tests. Results Twenty-nine out of 30 subjects remained implanted with functioning Argus II Systems at 3 years post-implant. Eleven subjects experienced a total of 23 serious device- or surgery-related adverse events. All were treated with standard ophthalmic care. As a group, subjects performed significantly better with the System ON than OFF on all visual function tests and functional vision assessments. Conclusions The three-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind from RP. Earlier results from this trial were used to gain approval of the Argus II by the FDA and a CE Mark in Europe. The Argus II System is the first and only retinal implant to have both approvals.
PURPOSE-To detect differences in retinal thickness among patients of different race, gender and age using Stratus OCT™. DESIGN-Cross-sectional study.METHODS-In a multicenter, university-based study, 126 patients with no history of ocular disease were enrolled (78 diabetics without retinopathy and 48 nondiabetics). Optical coherence tomography measurements were performed using Stratus OCT™. Statistical comparisons of centerpoint foveal thickness and mean foveal thickness were made using generalized estimating equations adjusting for diabetic status, race, age, and gender. RESULTS-The study population consisted of 36% males, 39% Caucasians, 33% African Americans, and 28% Hispanics. Mean foveal thickness was 191.6±2.7µm and 194.5±2.7µm for diabetics and nondiabetics, respectively (P=0.49). Mean foveal thickness in males was significantly larger than in females (201.8±2.7µm and 186.9±2.6µm, respectively; P<0.001). Mean foveal thickness was 200.2±2.7µm for Caucasians, 181.0±3.7µm for African Americans, and 194.7±3.9µm for Hispanics. Mean foveal thickness was significantly less for African Americans than Caucasians (P <0.0001) or Hispanics (P=0.005). Centerpoint foveal thickness and mean foveal thickness showed a significant increase with age.CONCLUSIONS-There are statistically significant differences in retinal thickness between subjects of different race, gender, and age. When compared to Caucasians and Hispanics, AfricanAmerican race is a predictor of decreased mean foveal thickness; and male sex (regardless of race) is a significant predictor of increased mean foveal thickness. Mean foveal thickness is similar among diabetics and nondiabetics when data are controlled for age, race, and sex. These results suggest that Publisher's Disclaimer: This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final citable form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain. (Fraser-Bell S, et al. IOVS 2005;46:ARVO E-Abstract 1542) suggests differences in retinal thickness based on age, gender, ethnicity, and refractive error; however, very few published studies have systematically attempted to establish a normative range of optical coherence tomography (OCT) measurements in healthy patients. Such a database is important for identifying and characterizing pathologic changes. Asrani and colleagues 1 used a retinal thickness analyzer to measure retinal thickness in a small sample (n=29) of normal patients. Their results suggested that race and gender have a small effect (< 35 microns) on retinal thickness, but the authors found no correlation between retinal thickness and age. Wong and colleagues2 reported that a larger body mass index, higher axial length and male gender were...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.