Heart failure with preserved ejection fraction (HFPEF) evolves with the accumulation of risk factors. Relevant animal models to identify potential therapeutic targets and to test novel therapies for HFPEF are missing. We induced hypertension and hyperlipidemia in landrace pigs (n = 8) by deoxycorticosteroneacetate (DOCA, 100 mg/kg, 90-day-release subcutaneous depot) and a Western diet (WD) containing high amounts of salt, fat, cholesterol, and sugar for 12 wk. Compared with weight-matched controls (n = 8), DOCA/WD-treated pigs showed left ventricular (LV) concentric hypertrophy and left atrial dilatation in the absence of significant changes in LV ejection fraction or symptoms of heart failure at rest. The LV end-diastolic pressure-volume relationship was markedly shifted leftward. During simultaneous right atrial pacing and dobutamine infusion, cardiac output reserve and LV peak inflow velocities were lower in DOCA/WD-treated pigs at higher LV end-diastolic pressures. In LV biopsies, we observed myocyte hypertrophy, a shift toward the stiffer titin isoform N2B, and reduced total titin phosphorylation. LV superoxide production was increased, in part attributable to nitric oxide synthase (NOS) uncoupling, whereas AKT and NOS isoform expression and phosphorylation were unchanged. In conclusion, we developed a large-animal model in which loss of LV capacitance was associated with a titin isoform shift and dysfunctional NOS, in the presence of preserved LV ejection fraction. Our findings identify potential targets for the treatment of HFPEF in a relevant large-animal model.
We conclude that the loss of LV end-diastolic capacitance during MH can be explained at least in part by slowed LV relaxation. MH thereby is an example of incomplete LV relaxation at a spontaneous low heart rate. Caution may be advised, when heart rate is increased in patients treated with MH.
Cooling from hyperthermia to normothermia and from normothermia to mild hypothermia increased left ventricular contractility to a similar degree as a significant dose of dobutamine in the normal porcine heart. These data indicate that cooling can reduce the need for positive inotropes and that lower rather than higher temperatures are appropriate for the resuscitated failing heart.
Background
Multiple wearable devices for rhythm analysis have been developed using either photoplethysmography (PPG) or handheld ECG.
Hypothesis
The aim of this survey was to assess impact of these technologies on physicians' clinical decision‐making regarding initiation of diagnostic steps, drug therapy, and invasive strategies.
Methods
The online survey included 10 questions on types of devices, advantages, and disadvantages of wearable devices as well as case scenarios for patients with supraventricular arrhythmias and atrial fibrillation (AF).
Results
A total of 417 physicians (median age 37 [IQR 32‐43] years) from 42 countries world‐wide completed the survey.
When presented a tracing of a regular tachycardia by a symptomatic patient, most participants would trigger further diagnostic steps (90% for single‐lead ECG vs 83% for PPG, P < .001), while a single‐lead ECG would be sufficient to perform an invasive EP study in approximately half of participants (51% vs 22% for PPG, P < .001).
When presented with a single‐lead ECG tracing suggesting AF, most participants (90%) would trigger further diagnostic steps. A symptomatic AF patient would trigger anticoagulation treatment to a higher extent as an asymptomatic patient (59% vs 21%, P < .001). PPG tracings would only rarely lead to therapeutic steps regardless of symptoms.
Most participants would like scientific society recommendations on the use of wearable devices (62%).
Conclusions
Tracings from wearable rhythm devices suggestive of arrhythmias are most likely to trigger further diagnostic steps, and in the case of PPG recordings rarely therapeutic interventions. A majority of participants expect these devices to facilitate diagnostics and arrhythmia screening but fear data overload and expect scientific society recommendations on the use of wearables.
The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. BACKGROUND The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. METHODS The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. RESULTS A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and predischarge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. CONCLUSIONS In this multicenter registry, transfemoral TAVR with the NEO and PRO bioprostheses was associated with high device success, acceptable rates of paravalvular aortic regurgitation II+, and good 30-day clinical outcomes. After adjusting for potential confounders, short-term outcomes were similar between the devices.
Novel wearable devices for heart rhythm analysis using either photoplethysmography (PPG) or electrocardiogram (ECG) are in daily clinical practice. This survey aimed to assess impact of these technologies on physicians’ clinical decision-making and to define, how data from these devices should be presented and integrated into clinical practice. The online survey included 22 questions, focusing on the diagnosis of atrial fibrillation (AF) based on wearable rhythm device recordings, suitable indications for wearable rhythm devices, data presentation and processing, reimbursement, and future perspectives. A total of 539 respondents {median age 38 [interquartile range (IQR) 34–46] years, 29% female} from 51 countries world-wide completed the survey. Whilst most respondents would diagnose AF (83%), fewer would initiate oral anticoagulation therapy based on a single-lead ECG tracing. Significantly fewer still (27%) would make the diagnosis based on PPG-based tracing. Wearable ECG technology is acceptable for the majority of respondents for screening, diagnostics, monitoring, and follow-up of arrhythmia patients, while respondents were more reluctant to use PPG technology for these indications. Most respondents (74%) would advocate systematic screening for AF using wearable rhythm devices, starting at patients’ median age of 60 (IQR 50–65) years. Thirty-six percent of respondents stated that there is no reimbursement for diagnostics involving wearable rhythm devices in their countries. Most respondents (56.4%) believe that costs of wearable rhythm devices should be shared between patients and insurances. Wearable single- or multiple-lead ECG technology is accepted for multiple indications in current clinical practice and triggers AF diagnosis and treatment. The unmet needs that call for action are reimbursement plans and integration of wearable rhythm device data into patient’s files and hospital information systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.