The study of lung emphysema dates back to the beginning of the 17th century. Nevertheless, a number of important questions remain unanswered because a quantitative localized characterization of emphysema requires knowledge of lung structure at the alveolar level in the intact living lung. This information is not available from traditional imaging modalities and pulmonary function tests. Herein, we report the first in vivo measurements of lung geometrical parameters at the alveolar level obtained with 3 He diffusion MRI in healthy human subjects and patients with severe emphysema. We also provide the first experimental data demonstrating that 3 He gas diffusivity in the acinus of human lung is highly anisotropic. A theory of anisotropic diffusion is presented. Our results clearly demonstrate substantial differences between healthy and emphysematous lung at the acinar level and may provide new insights into emphysema progression. The technique offers promise as a clinical tool for early diagnosis of emphysema.C hronic obstructive pulmonary disease in general and emphysema in particular are leading causes of death in industrialized countries and account for a substantial portion of health care spending (1). Several definitions of emphysema have been formulated by scientific bodies: according to ref. 2, emphysema is ''a condition of the lung characterized by abnormal, permanent enlargement of air spaces distal to the terminal bronchioles, accompanied by destruction of their walls, without fibrosis.'' This definition means that an accurate characterization of emphysema requires diagnostic methods that are noninvasive and sensitive to the regional lung microstructure at the alveolar level in the living lung. Diffusion MRI of 3 He gas, which has become available after recent advances in the physics of optical pumping and semiconductor diode lasers (see, for example, refs. 3-5), can provide this sensitivity. Previously, we and others have suggested (6-10) that measurement of 3 He gas diffusivity in the lung air spaces has potential for identifying changes in lung structure from emphysema at the alveolar level.In any medium, atoms or molecules diffuse; that is, atoms perform a Brownian-motion random walk. In time interval ⌬, in the absence of restricting walls or barriers, molecules will move a rms distance l 0 ϭ (2D 0 ⌬) 1/2 along any axis. The parameter D 0 is termed the free diffusion coefficient, which for 3 He in air at 37°C is D 0 ϭ 0.88 cm 2 ͞sec. Hence 3 He gas atoms can wander distances on the order of 1 mm in times as short as 1 ms. The alveolar walls, as well as the walls of bronchioles, alveolar ducts, sacs, and other branches of the airway tree, serve as obstacles to the path of diffusing 3 He atoms and reduce 3 He displacement. Indeed, the MR-measured average 3 He diffusion coefficient (the so-called apparent diffusion coefficient or ADC) in healthy human lungs is about 0.20 cm 2 ͞sec, more than a factor of four smaller than the free diffusion coefficient of 3 He in air (6, 7). In emphysema, the restriction...
Background The National Lung Screening Trial was conducted to determine whether three annual screenings (rounds T0, T1, and T2) with low-dose helical computed tomography (CT), as compared with chest radiography, could reduce mortality from lung cancer. We present detailed findings from the first two incidence screenings (rounds T1 and T2). Methods We evaluated the rate of adherence of the participants to the screening protocol, the results of screening and downstream diagnostic tests, features of the lung-cancer cases, and first-line treatments, and we estimated the performance characteristics of both screening methods. Results At the T1 and T2 rounds, positive screening results were observed in 27.9% and 16.8% of participants in the low-dose CT group and in 6.2% and 5.0% of participants in the radiography group, respectively. In the low-dose CT group, the sensitivity was 94.4%, the specificity was 72.6%, the positive predictive value was 2.4%, and the negative predictive value was 99.9% at T1; at T2, the positive predictive value increased to 5.2%. In the radiography group, the sensitivity was 59.6%, the specificity was 94.1%, the positive predictive value was 4.4%, and the negative predictive value was 99.8% at T1; both the sensitivity and the positive predictive value increased at T2. Among lung cancers of known stage, 87 (47.5%) were stage IA and 57 (31.1%) were stage III or IV in the low-dose CT group at T1; in the radiography group, 31 (23.5%) were stage IA and 78 (59.1%) were stage III or IV at T1. These differences in stage distribution between groups persisted at T2. Conclusions Low-dose CT was more sensitive in detecting early-stage lung cancers, but its measured positive predictive value was lower than that of radiography. As compared with radiography, the two annual incidence screenings with low-dose CT resulted in a decrease in the number of advanced-stage cancers diagnosed and an increase in the number of early-stage lung cancers diagnosed. (Funded by the National Cancer Institute; NLST ClinicalTrials.gov number, NCT00047385.)
BACKGROUND.The link between mucus plugs and airflow obstruction has not been established in chronic severe asthma, and the role of eosinophils and their products in mucus plug formation is unknown. METHODS.In clinical studies, we developed and applied a bronchopulmonary segment-based scoring system to quantify mucus plugs on multidetector computed tomography (MDCT) lung scans from 146 subjects with asthma and 22 controls, and analyzed relationships among mucus plug scores, forced expiratory volume in 1 second (FEV1), and airway eosinophils. Additionally, we used airway mucus gel models to explore whether oxidants generated by eosinophil peroxidase (EPO) oxidize cysteine thiol groups to promote mucus plug formation. RESULTS.Mucus plugs occurred in at least 1 of 20 lung segments in 58% of subjects with asthma and in only 4.5% of controls, and the plugs in subjects with asthma persisted in the same segment for years. A high mucus score (plugs in ≥ 4 segments) occurred in 67% of subjects with asthma with FEV1 of less than 60% of predicted volume, 19% with FEV1 of 60%-80%, and 6% with FEV1 greater than 80% (P < 0.001) and was associated with marked increases in sputum eosinophils and EPO. EPO catalyzed oxidation of thiocyanate and bromide by H 2 O 2 to generate oxidants that crosslink cysteine thiol groups and stiffen thiolated hydrogels. CONCLUSION.Mucus plugs are a plausible mechanism of chronic airflow obstruction in severe asthma, and EPO-generated oxidants may mediate mucus plug formation. We propose an approach for quantifying airway mucus plugging using MDCT lung scans and suggest that treating mucus plugs may improve airflow in chronic severe asthma. TRIAL REGISTRATION. Clinicaltrials.gov NCT01718197, NCT01606826, NCT01750411, NCT01761058, NCT01761630, NCT01759186, NCT01716494, and NCT01760915.FUNDING. NIH grants P01 HL107201, R01 HL080414, U10 HL109146, U10 HL109164, U10 HL109172, U10 HL109086, U10 HL109250, U10 HL109168, U10 HL109257, U10 HL109152, and P01 HL107202 and National Center for Advancing Translational Sciences grants UL1TR0000427, UL1TR000448, and KL2TR000428.
Background Lung cancer screening with low-dose computed tomography (LDCT) has been recommended, based primarily on the results of the NLST (National Lung Screening Trial). The American College of Radiology recently released Lung-RADS, a classification system for LDCT lung cancer screening. Objective To retrospectively apply the Lung-RADS criteria to the NLST. Design Secondary analysis of a group from a randomized trial. Setting 33 U.S. screening centers. Patients Participants were randomly assigned to the LDCT group of the NLST, were aged 55 to 74 years, had at least a 30–pack-year history of smoking, and were current smokers or had quit within the past 15 years. Intervention 3 annual LDCT lung cancer screenings. Measurements Lung-RADS classifications for LDCT screenings. Lung-RADS categories 1 to 2 constitute negative screening results, and categories 3 to 4 constitute positive results. Results Of 26 722 LDCT group participants, 26 455 received a baseline screening; 48 671 screenings were done after baseline. At baseline, the false-positive result rate (1 minus the specificity rate) for Lung-RADS was 12.8% (95% CI, 12.4% to 13.2%) versus 26.6% (CI, 26.1% to 27.1%) for the NLST; after baseline, the false-positive result rate was 5.3% (CI, 5.1% to 5.5%) for Lung-RADS versus 21.8% (CI, 21.4% to 22.2%) for the NLST. Baseline sensitivity was 84.9% (CI, 80.8% to 89.0%) for Lung-RADS versus 93.5% (CI, 90.7% to 96.3%) for the NLST, and sensitivity after baseline was 78.6% (CI, 74.6% to 82.6%) for Lung-RADS versus 93.8% (CI, 91.4% to 96.1%) for the NLST. Limitation Lung-RADS criteria were applied retrospectively. Conclusion Lung-RADS may substantially reduce the false-positive result rate; however, sensitivity is also decreased. The effect of using Lung-RADS criteria in clinical practice must be carefully studied. Primary Funding Source National Institutes of Health.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.