Shear wave elastography (SWE) techniques have received substantial attention in recent years. Strong experimental data in SWE suggest that shear wave speed changes significantly due to the known acoustoelastic effect (AE). This presents both challenges and opportunities toward in vivo characterization of biological soft tissues. In this work, under the framework of continuum mechanics, we model a tissue-mimicking material as a homogeneous, isotropic, incompressible, hyperelastic material. Our primary objective is to quantitatively and qualitatively compare experimentally measured acoustoelastic data with model-predicted outcomes using multiple strain energy functions. Our analysis indicated that the classic neo-Hookean and Mooney-Rivlin models are inadequate for modeling the AE in tissue-mimicking materials. However, a subclass of strain energy functions containing both high-order /exponential term(s) and second-order invariant dependence showed good agreement with experimental data. Based on data investigated, we also found that discrepancies may exist between parameters inversely estimated from uniaxial compression and SWE data. Overall, our findings may improve our understanding of clinical SWE results.
Our primary objective of this work was to design and test a new time-of-flight (TOF) method that allows measurements of shear wave speed (SWS) following impulsive excitation in soft tissues. Particularly, under the assumption of the local plane shear wave, this work named the Fourier-domain shift matching (FDSM) method, estimates SWS by aligning a series of shear waveforms either temporally or spatially using a solution space deduced by characteristic curves of the well-known 1-D wave equation. The proposed SWS estimation method was tested using computer-simulated data, and tissue-mimicking phantom and ex vivo tissue experiments. Its performance was then compared with three other known TOF methods: lateral time-to-peak (TTP) method with robust random sampling consensus (RANSAC) fitting method, Radon sum transformation method, and a modified cross correlation method. Hereafter, these three TOF methods are referred to as the TTP-RANSAC, Radon sum, and X-corr methods, respectively. In addition to an adapted form of the 2-D Fourier transform (2-D FT)-based method in which the (group) SWS was approximated by averaging phase SWS values was considered for comparison. Based on data evaluated, we found that the overall performance of the above-mentioned temporal implementation of the proposed FDSM method was most similar to the established Radon sum method (correlation = 0.99, scale factor = 1.03, and mean difference = 0.07 m/s), and the 2-D FT (correlation = 0.98, scale factor = 1.00, and mean difference = 0.10 m/s) at high signal quality. However, results obtained from the 2-D FT method diverged (correlation = 0.201) from these of the proposed temporal implementation in the presence of diminished signal quality, whereas the agreement between the Radon sum approach and the proposed temporal implementation largely remained the same (correlation = 0.98).
Shear wave elastography (SWE) techniques have received substantial attention in recent years. Strong experimental data in SWE suggest that shear wave speed changes significantly due to the known acoustoelastic effect (AE). This presents both challenges and opportunities toward in vivo characterization of biological soft tissues. In this work, under the framework of continuum mechanics, we model a tissue-mimicking material as a homogeneous, isotropic, incompressible, hyperelastic material. Our primary objective is to quantitatively and qualitatively compare experimentally measured acoustoelastic data with model-predicted outcomes using multiple strain energy functions. Our analysis indicated that the classic neo-Hookean and Mooney-Rivlin models are inadequate for modeling the AE in tissue-mimicking materials. However, a subclass of strain energy functions containing both high-order /exponential term(s) and second-order invariant dependence showed good agreement with experimental data. Based on data investigated, we also found that discrepancies may exist between parameters inversely estimated from uniaxial compression and SWE data. Overall, our findings may improve our understanding of clinical SWE results.
Viscoelasticity Imaging (VEI) has been proposed to measure relaxation time constants for characterization of in-vivo breast lesions. In this technique, external compression forces on tissue being imaged are maintained for a fixed period of time to induce strain creep. A sequence of ultrasound echo signals are then utilized to generate time-resolved strain measurements. Relaxation time constants can be obtained by fitting local time-resolved strain measurements to a viscoelastic tissue model (e.g. a modified Kevin-Voigt model). In this study, our primary objective is to quantitatively evaluate the contrast transfer efficiency (CTE) of VEI, which contains useful information regarding image interpretations. Using an open-source simulator for virtual breast quasi-static elastography (VBQE), we conducted a case study of contrast transfer efficiency of VEI. In multiple three-dimensional numerical breast phantoms containing various degrees of heterogeneity, finite element (FE) simulations in conjunction with quasi-linear viscoelastic constitutive tissue models were performed to mimic data acquisition of VEI under freehand scanning. Our results suggested that there were losses in CTE and the losses could be as high as -18 dB. FE results also qualitatively corroborated clinical observations, e.g. artifacts around tissue interfaces.
Many of the current techniques in transient elastography, such as shear wave elastography (SWE) assume a dominant planar shear wave propagating in an infinite medium. This underlying assumption, however, can be easily violated in real scenarios in vivo, leading to image artifacts and reconstruction errors. Other approaches that are not bound to planar shear wave assumption, such solutions based on the partial differential equation, can potentially overcome the shortcomings of the conventional SWE. The main objective of this paper is to demonstrate the advantages of the modified error in constitutive equations (MECE) formulation with total variation regularization (MECE + TV) over SWE in reconstructing the elastic moduli of different tissue-mimicking phantoms. Experiments were conducted on phantoms with inclusions of well-defined shapes to study the reconstruction of specific features relevant to practical applications. We compared the performances of MECE + TV and SWE in terms of quantitative metrics to estimate reconstruction accuracy, inclusion shape recovery, edge preservation and edge sharpness, inclusion size representation, and shear elasticity and contrast accuracies. The results indicate that the MECE + TV approach outperforms SWE based on several of these metrics. It is concluded that, with further development, the proposed method may offer elastography reconstructions that are superior to SWE in clinical applications.
Objective. Detrusor overactivity (DO) is a urodynamic observation characterized by fluctuations in detrusor pressure (P det) of the bladder. Although detecting DO is important for the management of bladder symptoms, the invasive nature of urodynamic studies (UDS) makes it a source of discomfort and morbidity for patients. Ultrasound bladder vibrometry (UBV) could provide a direct and noninvasive means of detecting DO, due to its sensitivity to changes in elasticity and load in the bladder wall. In this study, we investigated the feasibility and applying UBV toward detecting DO. Approach. UBV and urodynamic study (UDS) measurements were collected in 76 neurogenic bladder patients (23 with DO). Timestamped group velocity squared ( c g 2 ) data series were collected from UBV measurements. Concurrent P det data series were identically analyzed for comparison and validation. A processing approach is developed to separate transient fluctuations in the data series from the larger trend of the data and a DO index is proposed for characterizing the transient peaks observed in the data. Main Results. Applying the DO index as a classifier for DO produced sensitivities and specificities of 0.70 and 0.75 for c g 2 data series and 0.70 and 0.83 for P det data series respectively. Significance. It was found that DO can be feasibly detected from data series of timestamped UBV measurements. Collectively, these initial results are promising, and further refinement to the UBV measurement process is likely to improve and clarify its capabilities for noninvasive detection of DO.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.