BACKGROUNDThe subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODSWe conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTSA total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONSIn patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to devicerelated complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.
AimThe neural cardiac therapy for heart failure (NECTAR-HF) was a randomized sham-controlled trial designed to evaluate whether a single dose of vagal nerve stimulation (VNS) would attenuate cardiac remodelling, improve cardiac function and increase exercise capacity in symptomatic heart failure patients with severe left ventricular (LV) systolic dysfunction despite guideline recommended medical therapy.MethodsPatients were randomized in a 2 : 1 ratio to receive therapy (VNS ON) or control (VNS OFF) for a 6-month period. The primary endpoint was the change in LV end systolic diameter (LVESD) at 6 months for control vs. therapy, with secondary endpoints of other echocardiography measurements, exercise capacity, quality-of-life assessments, 24-h Holter, and circulating biomarkers.ResultsOf the 96 implanted patients, 87 had paired datasets for the primary endpoint. Change in LVESD from baseline to 6 months was −0.04 ± 0.25 cm in the therapy group compared with −0.08 ± 0.32 cm in the control group (P = 0.60). Additional echocardiographic parameters of LV end diastolic dimension, LV end systolic volume, left ventricular end diastolic volume, LV ejection fraction, peak V02, and N-terminal pro-hormone brain natriuretic peptide failed to show superiority compared to the control group. However, there were statistically significant improvements in quality of life for the Minnesota Living with Heart Failure Questionnaire (P = 0.049), New York Heart Association class (P = 0.032), and the SF-36 Physical Component (P = 0.016) in the therapy group.ConclusionVagal nerve stimulation as delivered in the NECTAR-HF trial failed to demonstrate a significant effect on primary and secondary endpoint measures of cardiac remodelling and functional capacity in symptomatic heart failure patients, but quality-of-life measures showed significant improvement.
AimsRemote management of heart failure using implantable electronic devices (REM-HF) aimed to assess the clinical and cost-effectiveness of remote monitoring (RM) of heart failure in patients with cardiac implanted electronic devices (CIEDs).Methods and resultsBetween 29 September 2011 and 31 March 2014, we randomly assigned 1650 patients with heart failure and a CIED to active RM or usual care (UC). The active RM pathway included formalized remote follow-up protocols, and UC was standard practice in nine recruiting centres in England. The primary endpoint in the time to event analysis was the 1st event of death from any cause or unplanned hospitalization for cardiovascular reasons. Secondary endpoints included death from any cause, death from cardiovascular reasons, death from cardiovascular reasons and unplanned cardiovascular hospitalization, unplanned cardiovascular hospitalization, and unplanned hospitalization. REM-HF is registered with ISRCTN (96536028). The mean age of the population was 70 years (range 23–98); 86% were male. Patients were followed for a median of 2.8 years (range 0–4.3 years) completing on 31 January 2016. Patient adherence was high with a drop out of 4.3% over the course of the study. The incidence of the primary endpoint did not differ significantly between active RM and UC groups, which occurred in 42.4 and 40.8% of patients, respectively [hazard ratio 1.01; 95% confidence interval (CI) 0.87–1.18; P = 0.87]. There were no significant differences between the two groups with respect to any of the secondary endpoints or the time to the primary endpoint components.ConclusionAmong patients with heart failure and a CIED, RM using weekly downloads and a formalized follow up approach does not improve outcomes.
Objective-To investigate whether physiological cardiac reserve can be measured in man without invasive procedures and whether it is a major determinant of exercise capacity. Design-Development of method of measurement and an observational study. Setting-A regional cardiothoracic centre. Subjects-70 subjects with a wide range of cardiac function, from heart failure patients to athletes. Methods-Subjects underwent treadmill, symptom limited cardiopulmonary exercise tests to measure aerobic exercise capacity (represented by Ṽ O 2 max) and cardiac reserve. Cardiac output was measured non-invasively using the CO 2 rebreathing technique. Results-Cardiac power output (CPO max ) at peak exercise was found to be significantly related to aerobic capacity: CPO max (W) = 0.35 + 1.5Ṽ O 2 max (l/min), r = 0.87, p < 0.001. It also correlated well with exercise duration (r = 0.62, p < 0.001), suggesting that cardiac reserve is a major determinant of exercise capacity. In the study, cardiac reserve ranged from 0.27 to 5.65 W, indicating a 20-fold diVerence between the most impaired cardiac function and that of the fittest subject. Conclusions-A non-invasive method of estimating physiological cardiac reserve was developed. The reserve was found to be a major determinant of exercise capacity in a population of normal subjects and patients with heart disease. This method may thus be used to provide a clearer definition of the extent of cardiac impairment in patients with heart failure. (Heart 1998;79:289-294)
Non-UK purchasers will have to pay a small fee for post and packing. For European countries the cost is £2 per monograph and for the rest of the world £3 per monograph.You can order HTA monographs from our Despatch Agents:-fax (with credit card or official purchase order) -post (with credit card or official purchase order or cheque) -phone during office hours (credit card only).Additionally the HTA website allows you either to pay securely by credit card or to print out your order and then post or fax it. NHS libraries can subscribe free of charge. Public libraries can subscribe at a very reduced cost of £100 for each volume (normally comprising 30-40 titles). The commercial subscription rate is £300 per volume. Please see our website for details. Subscriptions can only be purchased for the current or forthcoming volume. Contact details are as follows: Payment methods Paying by chequeIf you pay by cheque, the cheque must be in pounds sterling, made payable to Direct Mail Works Ltd and drawn on a bank with a UK address. Paying by credit cardThe following cards are accepted by phone, fax, post or via the website ordering pages: Delta, Eurocard, Mastercard, Solo, Switch and Visa. We advise against sending credit card details in a plain email. Paying by official purchase orderYou can post or fax these, but they must be from public bodies (i.e. NHS or universities) within the UK. We cannot at present accept purchase orders from commercial companies or from outside the UK. How do I get a copy of HTA on CD?Please use the form on the HTA website (www.hta.ac.uk/htacd.htm). Or contact Direct Mail Works (see contact details above) by email, post, fax or phone. HTA on CD is currently free of charge worldwide.The website also provides information about the HTA Programme and lists the membership of the various committees. Declared competing interests of authors: K Stein received an unrestricted grant from Schering Plough (UK) to carry out work on the cost-effectiveness of combination therapy for hepatitis C in 2000. KS is also a member of the editorial board for Health Technology Assessment, but he was not involved in the editorial process for this report. M Cramp sits on hepatitis C advisory boards for Schering Plough, Gilead and Roche. He has received unrestricted educational grants from Roche and Schering Plough to support research and service development. He has been awarded an NHS R&D grant looking at injecting drug users who do not have hepatitis C virus infection. J Thompson Coon received a grant from the Hepatitis C Trust to conduct a systematic review of complementary and alternative therapies for the treatment of chronic hepatitis C. HTA Published September 2007This report should be referenced as follows: NIHR Health Technology Assessment ProgrammeT he Health Technology Assessment (HTA) programme, now part of the National Institute for Health Research (NIHR), was set up in 1993. It produces high-quality research information on the costs, effectiveness and broader impact of health technologies for those who use, man...
Objectives To determine the effects of erectile dysfunction and to explore the impact of treatment with sildenafil (Viagra). Design An exploratory qualitative study with semistructured interviews. Setting Men's health clinic in NHS hospital. Participants 40 men who had had erectile dysfunction and had attended the clinic during the year before interview. Main outcome measures Impact of erectile dysfunction on men, their expectations of sildenafil, and impact of treatment on men and their relationships. Issues explored with exploratory qualitative approach. Results Erectile dysfunction caused serious distress to all those men who experienced it, with marked effects on their self esteem and their relationships. Sildenafil, when it worked, caused a great improvement in wellbeing. The expectations raised by media hyperbole with the launch of sildenafil had an adverse effect on the morale of those who found it did not work. When, according to the patient, treatment did not work, the distress was severe and for many confirmed their lack of self worth. Conclusions Further study is needed to explore the feelings of men affected by erectile dysfunction and their perception of treatment. Health professionals should be aware of the extreme distress erectile dysfunction can cause.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.