Despite a high dead-space volume (9-15 l), this new helmet interface is an efficient alternative to standard face mask during CPAP, even in cases of severe respiratory acidosis and hypercapnia. It allowed to provide long-duration CPAP, without any adverse events or clinical intolerance.
Artificial airway dead-space reduction allows a significant PaCO(2) reduction. Independently of any respiratory mechanical changes, this very simple maneuver may be of importance when low tidal volume ventilation is used in ARDS patients, and when PaCO(2) lowering is warranted.
Cystic fibrosis (CF) eventually leads to hyperinflation linked to tidal expiratory flow limitation (FL) and ventilatory failure.Presence of FL was assessed at rest in 22 seated children and adults with CF (forced expiratory volume in one second (FEV1) range: 16-92% predicted), using both the negative expiratory pressure (NEP) technique and the "conventional" method based on comparison of tidal and maximal expiratory flow/volume curves. In addition, chronic dyspnoea was scored with the modified Medical Research Council (MRC) scale. Measurements were made before and 15 min after inhalation of salbutamol.With NEP, FL was present in only three malnourished patients, who had the lowest FEV1 values (16-27% pred) and claimed very severe dyspnoea (MRC score 5). By contrast, an additional seven patients were classified as FL with the conventional method. Six of these patients had little or no dyspnoea (MRC scores 0-1). Salbutamol administration had no effect on the extent of FL, and the concomitant decrease in functional residual capacity (FRC) was too small to play any clinically significant role.This study concluded that in seated patients with cystic fibrosis, expiratory flow limitation is absent at rest, unless the forced expiratory volume in one second is v30% predicted. If present, expiratory flow limitation is associated with severe chronic dyspnoea. The conventional method for assessing expiratory flow limitation is not reliable and bronchodilator administration has little effect on expiratory flow limitation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.