Routine tests of anastomotic integrity are unnecessary. When clinically suspected, contrast swallow or CT with oral contrast will identify most leaks. Endoscopy is useful in cases where there are incongruous results.
IntroductionAnterior cruciate ligament reconstruction (ACLR) is associated with poor return to sport and high graft re-rupture rates. This study explored the use of a wearable inertial sensor (ViMove) that incorporates an accelerometer and gyroscope, and MatScan pressure sensing mat (TekScan, South Boston, Massachusetts, USA) to provide objective return-to-sport measures.MethodsThree cohorts’ ACLR patients, non-athletic controls and elite athletes (Australian seven’s rugby Olympic Gold medallist). Patients performed biometric and functional tests (thigh circumference and triple hop) and the ViMove knee module (consisting of single and double leg squats, hops and box drops) for lower limb alignment assessment, concurrently with force plate.ResultsElite athletes had less varus/valgus (VV) movement during ViMove exercises compared with the ACLR cohort, who in turn had less VV malalignment than controls. When analysing side-to-side differences, single leg squats and box drop were asymmetrical in the ACL group, with greater malalignment in the reconstructed leg (p<0.05). Subgroup analysis failed to differentiate who passed or failed current return to sport assessment. TekScan pressure plate detected differences in double leg landing and flight time while hopping not detected with ViMove, suggesting ACL patients compensate by offloading the reconstructed leg to improve coronal alignment during double leg activity.ConclusionThe inertial sensor detected differences in motion for patients following ACLR, which are known to be associated with graft rupture and were not detected with functional return to sport testing. Coupling the device with data from a pressure plate provides a powerful assessment tool detecting alignment differences known to be associate with graft failure only previously detected in formal gait analysis.
The three simulated tasks in combination are construct valid for differentiating experience levels among surgeons in training. This hybrid simulator has potential added benefits of marrying the virtual with actual, and of combining simple box traits and advanced virtual reality simulation.
Hamstring tendon autografts are used for reconstruction of the anterior cruciate ligament. This study tested the hypothesis that a 5-strand hamstring autograft construct is superior in strength to a 4-strand construct. Four-strand and 5-strand tendon grafts constructs were prepared from ovine flexor tendons and then tested in a uniaxial electromechanical load system with suspensory fixation. The 4-strand and 5-strand constructs were pre-conditioned, stress-relaxed and loaded to ultimate failure. Stress-relaxation, stiffness and ultimate load were compared using a one-way ANOVA. There were no statistical differences in stress-relaxation, initial stiffness, secondary stiffness or ultimate load between 4-strand and 5-strand split tendon graft constructs. Inconsistent failure patterns for both 4-strand and 5-strand constructs were observed. The additional strand in the 5-strand construct may be shielded from stress with additional weakness secondary to the use of suspensory fixation. The potential biological benefit of religamentization and bony integration, with more autologous tissue in the intra-articular space and bony tunnels remains unknown.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.