Eighteen percent of bleeding ED patients are coagulopathic using ROTEM including 25% of trauma patients. A 10-min ROTEM clot firmness (A10) is an excellent surrogate for MCF and allows a result to be obtained earlier than formal laboratory results and potentially within 10 min of the patient arriving in the ED.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.