We report an experimental proof of principle for ghost imaging in the hard x-ray energy range. We used a synchrotron x-ray beam that was split using a thin crystal in Laue diffraction geometry. With an ultra-fast imaging camera, we were able to image x-rays generated by isolated electron bunches. At this time scale, the shot noise of the synchrotron emission process is measurable as speckles, leading to speckle correlation between the two beams. The integrated transmitted intensity from a sample located in the first beam was correlated with the spatially resolved intensity measured in the second, empty, beam to retrieve the shadow of the sample. The demonstration of ghost imaging with hard x-rays may open the way to protocols to reduce radiation damage in medical imaging and in non-destructive structural characterization using Free Electron Lasers.Ghost imaging, in its basic form, is the technique of indirectly imaging a sample by using the correlation between the intensity recorded at two detectors illuminated by spatially separated correlated beams [1]. A bucket detector measures the total intensity transmitted (or scattered) by a sample, placed in one of the beams. The sample image is then retrieved by correlating the output of the bucket detector with a pixel array detector located in the other beam, namely the one that has not directly interacted with the sample. Initially demonstrated with entangled photon pairs [2], ghost imaging was subsequently performed using correlation between classical coherent light beams [3]. The protocol was shown to be very robust, leading to experimental studies on ghost imaging using pseudo-thermal light [4][5][6], true thermal sources [7], and eventually computational ghost imaging [8], where a computer-controlled spatial light modulator generates a series of known illuminating fields, altogether removing the need for imaging the empty beam. Of relevance for this paper is also a very recent demonstration of Fourier transform ghost imaging using speckle fields generated with partially coherent synchrotron x-rays [9]. At the heart of thermal ghost imaging is the speckle correlation in the intensity fluctuations of the illuminating beam. The speckles can be produced either by nearfield diffraction of a coherent beam by a slowly moving diffracting object [4-6, 9], or taking advantage of the natural fluctuations of true thermal light [7], as in the Hanbury Brown-Twiss (intensity) interferometer [10]. In this Letter we use the latter mechanism to produce the first proof of principle demonstration of hard x-ray direct ghost imaging using synchrotron emission from an undulator in a third generation synchrotron storage ring. Synchrotron emission from an ultra-relativistic electron bunch provides a natural thermal source of hard x-rays. Intensity correlation x-ray experiments, proposed as far back as 1975 [11] (see also [12]), were employed several times for coherence characterization of synchrotron [13][14][15] and x-ray Free Electron Laser (FEL) [16] beams. To date though, x-ray spec...
A practical experimental procedure for transmission X-ray ghost imaging (XGI) using synchrotron light is presented. The authors demonstrate the method, discuss data acquisition and analysis, and measure the point-spread function of an XGI system. The generalization of the methods for future experiments is also discussed.
Ghost tomography using single-pixel detection extends the emerging field of ghost imaging to three dimensions, with the use of penetrating radiation. In this work, a series of spatially random x-ray intensity patterns is used to illuminate a specimen in various tomographic angular orientations with only the total transmitted intensity being recorded by a single-pixel camera (or bucket detector). The set of zero-dimensional intensity readings, combined with knowledge of the corresponding two-dimensional illuminating patterns and specimen orientations, is sufficient for three-dimensional reconstruction of the specimen. The experimental demonstration of ghost tomography is presented here using synchrotron hard x-rays. This result expands the scope of ghost imaging to encompass volumetric imaging ( i.e. , tomography), of optically opaque objects using penetrating radiation. For hard x-rays, ghost tomography has the potential to decouple image quality from dose rate as well as image resolution from detector performance.
Scanning X-ray fluorescence microscopy (XFM) is a particularly useful method for studying the spatial distribution of trace metals in biological samples. Here we demonstrate the utility of combining coherent diffractive imaging (CDI) with XFM for imaging biological samples to simultaneously produce high-resolution and high-contrast transmission images and quantitative elemental maps. The reconstructed transmission function yields morphological details which contextualise the elemental maps. We report enhancement of the spatial resolution in both the transmission and fluorescence images beyond that of the X-ray optics. The freshwater diatom Cyclotella meneghiniana was imaged to demonstrate the benefits of combining these techniques that have complementary contrast mechanisms.
A simultaneous, contextual experimental demonstration of the two processes of cloning an input qubit |Ψ >and of flipping it into the orthogonal qubit |Ψ ⊥ > is reported. The adopted experimental apparatus, a Quantum-Injected Optical Parametric Amplifier (QIOPA) is transformed simultaneously into a Universal Optimal Quantum Cloning Machine (UOQCM) and into a Universal NOT quantum-information gate. The two processes, indeed forbidden in their exact form for fundamental quantum limitations, will be found to be universal and optimal, i.e. the measured fidelity of both processes F < 1 will be found close to the limit values evaluated by quantum theory. A contextual theoretical and experimental investigation of these processes, which may represent the basic difference between the classical and the quantum worlds, can reveal in a unifying manner the detailed structure of quantum information. It may also enlighten the yet little explored interconnections of fundamental axiomatic properties within the deep structure of quantum mechanics. PACS numbers:03.67.-a, 03.65.Ta, 03.65.Ud
A simultaneous realization of the universal optimal quantum cloning machine and of the universal-NOT gate by a quantum injected optical parametric amplification, is reported. The two processes, forbidden in their exact form for fundamental quantum limitations, are found universal and optimal, and the measured fidelity F<1 is found close to the limit values evaluated by quantum theory. This work may enlighten the yet little explored interconnections of fundamental axiomatic properties within the deep structure of quantum mechanics.
Therapeutic applications of synchrotron X-rays such as microbeam (MRT) and minibeam (MBRT) radiation therapy promise significant advantages over conventional clinical techniques for some diseases if successfully transferred to clinical practice. Preclinical studies show clear evidence that a number of normal tissues in animal models display a tolerance to much higher doses from MRT compared with conventional radiotherapy. However, a wide spread in the parameters studied makes it difficult to make any conclusions about the associated tumour control or normal tissue complication probabilities. To facilitate more systematic and reproducible preclinical synchrotron radiotherapy studies, a dedicated preclinical station including small-animal irradiation stage was designed and installed at the Imaging and Medical Beamline (IMBL) at the Australian Synchrotron. The stage was characterized in terms of the accuracy and reliability of the vertical scanning speed, as this is the key variable in dose delivery. The measured speed was found to be within 1% of the nominal speed for the range of speeds measured by an interferometer. Furthermore, dose measurements confirm the expected relationship between speed and dose and show that the measured dose is independent of the scan direction. Important dosimetric parameters such as peak dose, valley dose, the collimator output factor and peak-to-valley dose ratio are presented for 5 mm × 5 mm, 10 mm × 10 mm and 20 mm × 20 mm field sizes. Finally, a feasibility study on three glioma-bearing rats was performed. MRT and MBRT doses were prescribed to achieve an average dose of 65 Gy in the target, and magnetic resonance imaging follow-up was performed at various time points after irradiation to follow the tumour volume. Although it is impossible to draw conclusions on the different treatments with such a small number of animals, the feasibility of end-to-end preclinical synchrotron radiotherapy studies using the IMBL preclinical stage is demonstrated.
A simple coherent-imaging method due to Paganin et al. is widely employed for phase-amplitude reconstruction of samples using a single paraxial x-ray propagation-based phase-contrast image. The method assumes that the sample-to-detector distance is sufficiently small for the associated Fresnel number to be large compared to unity. The algorithm is particularly effective when employed in a tomographic setting, using a single propagation-based phase-contrast image for each projection.Here we develop a simple extension of the method, which improves the reconstructed contrast of very fine sample features. This provides first-principles motivation for boosting fine spatial detail associated with high Fourier frequencies, relative to the original method, and was inspired by several recent works employing empirically-obtained Fourier filters to a similar end.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.