The detection of the abuse of pseudo-endogenous steroids (testosterone and/or its precursors) is currently based on the application of the steroid module of the World Anti-Doping Agency (WADA) Athletes' Biological Passport (ABP), implemented through ADAMS. Diagnostic metabolites are monitored for every athlete and statistically evaluated with a predictive Bayesian approach. In the case of suspicious samples, the data of the ABP are confirmed and the isotope ratio mass spectrometry (IRMS) test is activated. We have previously demonstrated that IRMS enables confirmation of the non-endogenous origin of pseudo-endogenous steroids in otherwise non-suspicious samples, after a longitudinal evaluation of the ABP, even after the inclusion of additional long-term diagnostic hydroxylated metabolites, and that the delta values of the parameters obtained during the IRMS confirmation process presented much less variability compared to the parameters of the ABP. The aim of the present work is to evaluate the application of the same methodology used for the evaluation of the ABP, on the delta values of the pseudo-endogenous steroids monitored. The effectiveness of the proposed model has been assessed on samples obtained after controlled administrations of oral androstenedione and transdermal testosterone. The results support the conclusion that, if applied, the longitudinal evaluation of the IRMS data allows the detection of positive samples that otherwise will be reported as atypical findings (ATF), improving the efficacy of the fight against doping in sport. This approach, by narrowing the individual acceptable range, could possibly improve the detection of the intake of preparations of synthetic origin with delta values close to or overlapping those of endogenously produced steroids. Copyright © 2016 John Wiley & Sons, Ltd.
Formestane (4-hydroxy-androstenedione) is an aromatase inhibitor prohibited in sports and included, since 2004, in the list of prohibited substances updated yearly by the World Anti-Doping Agency (WADA). Since the endogenous production of formestane has been described, it is mandatory for the anti-doping laboratories to use isotope ratio mass spectrometry (IRMS) to establish the exogenous origin before issuing an adverse analytical finding. The described IRMS methods for formestane detection are time-consuming, requiring usually two consecutive liquid chromatographic sample purifications in order to have final extracts of adequate purity before the mass spectrometric analysis. After establishing a procedure for the determination of the origin of formestane by IRMS without the need of derivatization, and integrated in the overall analytical strategy of the laboratory for pseudo-endogenous steroids, a mass spectrometric analysis by gas chromatography-mass spectrometry (GC-MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS) of formestane metabolites was carried out in order to investigate whether other biomarkers of formestane abuse could be integrated in order to avoid time-consuming and expensive IRMS confirmations for formestane. From the metabolic studies performed, the inclusion of 3β,4α-dihydroxy-5α-androstan-17-one (4α-hydroxy-epiandosterone) in the routine GC-MS procedures has demonstrated to be diagnostic in order to reduce the number of unnecessary confirmations of the endogenous origin of formestane.
This work demonstrates the high potential of combining high-resolution mass spectrometry with chemometric tools, using metabolomics as a guided tool for anti-doping analysis. The administration of 7-keto-DHEA was studied as a proofof-concept of the effectiveness of the combination of knowledge-based and machine-learning approaches to differentiate the changes due to the athletic activities from those due to the recourse to doping substances and methods.Methods: Urine samples were collected from five healthy volunteers before and after an oral administration by identifying three time intervals. Raw data were acquired by injecting less than 1 μL of derivatized samples into a model 8890 gas chromatograph coupled to a model 7250 accurate-mass quadrupole time-of-flight analyzer (both from Agilent Technologies), by using a low-energy electron ionization source; the samples were then preprocessed to align peak retention times with the same accurate mass. The resulting data table was subjected to multivariate analysis.Results: Multivariate analysis showed a high similarity between the samples belonging to the same collection interval and a clear separation between the different excretion intervals. The discrimination between blank and long excretion groups may suggest the presence of long excretion markers, which are particularly significant in anti-doping analysis. Furthermore, matching the most significant features with some of the metabolites reported in the literature data demonstrated the rationality of the proposed metabolomics-based approach.Conclusions: The application of metabolomics tools as an investigation strategy could reduce the time and resources required to identify and characterize intake markers maximizing the information that can be extracted from the data and extending the research field by avoiding a priori bias. Therefore, metabolic fingerprinting of prohibited substance intakes could be an appropriate analytical approach to reduce the risk of false-positive/negative results, aiding in the interpretation of "abnormal" profiles and discrimination of pseudo-endogenous steroid intake in the anti-doping field.
The detection of clostebol misuse in sports has been growing recently, especially in Italy, due to the ample availability of pharmaceutical formulations containing clostebol acetate (Trofodermin®) and the use of more sensitive instrumentation by the antidoping laboratories. Most of these cases have been claimed to be related to a nonconscious use of the drug or through contact with relatives or teammates using it. We have investigated, through the application of the well‐known and currently used gas chromatographic mass spectrometric procedures, the likelihood of these allegations and have demonstrated that after a single transdermal administration of 5 mg of clostebol acetate and a transient contact with the application area, it is possible to generate adverse analytical findings in antidoping controls. We have reviewed the Phase I and Phase II clostebol metabolism in order to generate evidences that may help the sport authorities reviewing these cases. The main clostebol metabolite (4‐chloro‐androst‐4‐en‐3α‐ol‐17‐one, M1) generally used at the screening level as well as other three metabolites (M2–M4) are mainly excreted as glucuronides, whereas M5 (4ζ‐chloro‐5ζ‐androstan‐3β‐ol‐17‐one) is predominantly excreted as sulfate. Neither the 5α‐reductases activity (impaired by the presence of the chlorine in C4) nor specific sulfotransferases present in the skin allowed a clear distinction of the administration route. Studies with a larger number of volunteers and probably investigating another physiological fluid allowed in antidoping such as blood are needed for a deeper investigation. It is not unreasonable to establish a reporting level for M1, maybe creating some false negatives but excluding nonintentional doping scenarios.
Rationale Isotope ratio mass spectrometry (IRMS) is an analytical technique required by the World Antidoping Agency (WADA) before releasing of an adverse finding for the abuse of pseudoendogenous steroids (i.e. testosterone). For every single individual, the delta 13C values (‰) of the selected target compounds (TCs, i.e. testosterone and/or its precursors/metabolites) are compared with those of endogenous reference compounds (ERCs). The aim of this work is to investigate the individual variation in the delta values of four different commonly used ERCs to establish the maximum acceptable variation, in order to detect potential outliers. Methods Routine urine samples collected for antidoping purposes were submitted to IRMS confirmation. After a specific liquid chromatographic purification of the analytes of interest, the final extracts were analyzed by gas chromatography/combustion (GC/C)‐IRMS. The selected ERCs monitored were pregnanediol, pregnanetriol, 11‐keto‐etiocholanolone and 11β‐hydroxyandrosterone. The obtained 13C delta values were statistically analyzed to evaluate their inter‐ and intra‐individual distribution. Results The delta values of the ERCs studied showed a normal distribution and no major differences among genders were observed. As expected, there are differences depending on the geographical origin of the samples, reflecting different dietary habits and food sources. The intra‐individual dispersion, expressed as the standard deviation (SD) of the values of the studied ERCs, did not greatly exceed the instrumental error (0.5‰), demonstrating the good preservation of the delta values along the metabolic pathway. Conclusions For the selected ERCs of non‐sporting volunteers and the urinary specimens from more than 1000 sportsmen, we can propose a maximum SD of 0.54‰ and range of 1.2‰ for delta 13C values as acceptance criteria to detect potential outliers. These cases can be caused by the external masking effect of the administration of a substance modifying the delta values or outliers due to unforeseen procedural artifacts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.