The literature supports the use of multimodality monitoring using all of the electrophysiological techniques that can provide intraoperative information about the neural structures at risk during the surgery.
During two cases of lumbar spine surgery with instrumentation, we used intraoperative autologous transfusion (IAT), resulting in hemolysis during collection and hemoglobinuria and coagulation abnormalities after transfusion. Hemolysis during IAT collection can lead to hemoglobinuria and binding of nitric oxide, leading to vasoconstriction. The literature suggests that stroma from damaged cells and contact of the blood with the IAT device can lead to coagulation abnormalities and other morbidities, including adult respiratory distress syndrome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.