The purpose of this form is to provide readers of your manuscript with information about your other interests that could influence how they receive and understand your work. The form is designed to be completed electronically and stored electronically. It contains programming that allows appropriate data display. Each author should submit a separate form and is responsible for the accuracy and completeness of the submitted information. The form is in six parts. ICMJE Form for Disclosure of Potential Conflicts of Interest 1 Chokshi The purpose of this form is to provide readers of your manuscript with information about your other interests that could influence how they receive and understand your work. The form is designed to be completed electronically and stored electronically. It contains programming that allows appropriate data display. Each author should submit a separate form and is responsible for the accuracy and completeness of the submitted information. The form is in six parts. Identifying information. The work under consideration for publication. This section asks for information about the work that you have submitted for publication. The time frame for this reporting is that of the work itself, from the initial conception and planning to the present. The requested information is about resources that you received, either directly or indirectly (via your institution), to enable you to complete the work. Checking "No" means that you did the work without receiving any financial support from any third party-that is, the work was supported by funds from the same institution that pays your salary and that institution did not receive third-party funds with which to pay you. If you or your institution received funds from a third party to support the work, such as a government granting agency, charitable foundation or commercial sponsor, check "Yes". Relevant financial activities outside the submitted work. This section asks about your financial relationships with entities in the bio-medical arena that could be perceived to influence, or that give the appearance of potentially influencing, what you wrote in the submitted work. You should disclose interactions with ANY entity that could be considered broadly relevant to the work. For example, if your article is about testing an epidermal growth factor receptor (EGFR) antagonist in lung cancer, you should report all associations with entities pursuing diagnostic or therapeutic strategies in cancer in general, not just in the area of EGFR or lung cancer. Report all sources of revenue paid (or promised to be paid) directly to you or your institution on your behalf over the 36 months prior to submission of the work. This should include all monies from sources with relevance to the submitted work, not just monies from the entity that sponsored the research. Please note that your interactions with the work's sponsor that are outside the submitted work should also be listed here. If there is any question, it is usually better to disclose a relationship than not to do s...
This study provides data on LIA with LB administered using optimal techniques specific to TKA. In this setting, LIA with LB significantly improved postsurgical pain, opioid consumption, and time to first opioid rescue, with more opioid-free patients and no unexpected safety concerns.
BackgroundPeripheral nerve stimulation has been used for decades to treat chronic pain but has not been used for postoperative analgesia due to multiple limitations, beginning with invasive electrode placement. With the development of small-diameter/gauge leads enabling percutaneous insertion, ultrasound guidance for accurate introduction, and stimulators small enough to be adhered to the skin, neurostimulation may now be provided in a similar manner to continuous peripheral nerve blocks. Here, we report on the use of ultrasound-guided percutaneous peripheral nerve stimulation to treat postoperative pain.Materials and methodsSubjects within 60 days of a total knee arthroplasty with pain insufficiently treated with oral analgesics had a 0.2-mm-diameter electrical lead (pre-loaded into a 20 gauge needle) introduced percutaneously using ultrasound guidance with the tip located approximately 0.5–1.0 cm from the femoral nerve (a second lead was inserted approximately 1.0–3.0 cm from the sciatic nerve for posterior knee pain). An external stimulator delivered current. Endpoints were assessed before and after lead insertion and the leads subsequently removed. Due to the small sample size for this pilot/feasibility study, no statistics were applied to the data.ResultsLeads were inserted in subjects (n = 5) 8–58 days postoperatively. Percutaneous peripheral nerve stimulation decreased pain an average of 93% at rest (from a mean of 5.0 to 0.2 on a 0–10 numeric rating scale), with 4 of 5 subjects experiencing complete resolution of pain. During passive and active knee motion pain decreased an average of 27 and 30%, respectively. Neither maximum passive nor active knee range-of-motion was consistently affected.ConclusionsUltrasound-guided percutaneous peripheral nerve stimulation may be a practical modality for the treatment of postoperative pain following orthopedic surgical procedures, and further investigation appears warranted.
Our results suggest that intraoperative MCL injury can be treated with primary repair followed by hinged knee bracing without the need for increased prosthetic constraint. Stiffness, however, was a common complication.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.