The propagation of ultraintense laser pulses through matter is connected with the generation of strong moving magnetic fields in the propagation channel as well as the formation of a thin ion filament along the axis of the channel. Upon exiting the plasma the magnetic field displaces the electrons at the back of the target, generating a quasistatic electric field that accelerates and collimates ions from the filament. Two dimensional particle-in-cell simulations show that a 1 PW laser pulse tightly focused on a near-critical density target is able to accelerate protons up to an energy of 1.3 GeV. Scaling laws and optimal conditions for proton acceleration are established considering the energy depletion of the laser pulse.
We consider the effect of laser beam shaping on proton acceleration in the interaction of a tightly focused pulse with ultrathin double-layer solid targets in the regime of directed Coulomb explosion. In this regime, the heavy ions of the front layer are forced by the laser to expand predominantly in the direction of the pulse propagation, forming a moving longitudinal charge separation electric field, thus increasing the effectiveness of acceleration of second-layer protons. The utilization of beam shaping, namely, the use of flat-top beams, leads to more efficient proton acceleration due to the increase of the longitudinal field.
Proton radiotherapy is a powerful tool in the local control of cancer. The advantages of proton radiotherapy over gamma-ray therapy arise from the phenomenon known as the Bragg peak. This phenomenon enables large doses to be delivered to well-defined volumes while sparing surrounding healthy tissue. To fully realize the potential of this technique the location of the high-dose volume must be controlled very accurately. An imaging system was designed and tested to monitor the positron-emitting activity created by the beam as a means of verifying the beam's range, monitoring dose, and determining tissue composition. The prototype imaging system consists of 12 pairs of cylindrical BGO detectors shielded in lead. Each crystal was 1.9 cm in diameter, 5.0 cm long, and separated by 0.5 cm from other detectors in the row. These are arranged in two rows, 60 cm apart, with the proton beam and tissue phantoms half-way between and parallel to the detector rows. Experiments were conducted with 150 MeV continuous and macro-pulsed proton beams which had beam currents ranging from 0.14 nA to 1.75 nA. The production and decay of short-lived isotopes, 15O and 14O, was studied using 1 min irradiations with a continuous beam. These isotopes provide a significant signal on short time scales, making on-line imaging possible. Macro-pulsed beams, having a period of 10 s, were used to study on-line imaging and the production and decay of long-lived isotopes, 13N, 11C, and 18F. Decay data were acquired and on-line images were obtained between beam pulses and indicate that range verification is possible, for a 150 MeV beam, after one beam pulse, to within the 1.2 cm resolution limit of the imaging system. The dose delivered to the patient may also be monitored by observing the increase in the number of coincidence events detected between successive beam pulses. Over 80% of the initial positron-emitting activity is from 15O while the remainder is primarily 11C, 13N, 14O with traces of 18F, and 10C. Radioisotopic imaging may also be performed along the beam path by fitting decay data collected after the treatment is complete. Using this technique, it is shown that variations in elemental composition in inhomogenous treatment volumes may be identified and used to locate anatomic landmarks. Radioisotopic imaging also reveals that 14O is created well beyond the Bragg peak, apparently by secondary neutrons.
Proton acceleration by high-intensity laser pulses from ultra-thin foils for hadron therapy is discussed. With the improvement of the laser intensity contrast ratio to 10 laser pulse propagation enhancing the longitudinal charge separation electric field that accelerates light ions. The dependence of the maximum proton energy on the foil thickness has been found and the laser pulse characteristics have been matched with the thickness of the target to ensure the most efficient acceleration. Moreover the proton spectrum demonstrates a peaked structure at high energies, which is required for radiation therapy. 2D PIC simulations show that a 150-500 TW laser pulse is able to accelerate protons up to 100-220 MeV energies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.