Objectives We aimed to evaluate the diagnostic accuracy of computation of fractional flow reserve (FFR) from a single angiographic view in patients with intermediate coronary stenosis. Background Computation of quantitative flow ratio (QFR) from a single angiographic view might increase the feasibility of routine use of computational FFR. In addition, current QFR solutions assume a linear tapering of the reference vessel size, which might decrease the diagnostic accuracy in the presence of the physiologically significant bifurcation lesions. Methods An artificial intelligence algorithm was proposed for automatic delineation of lumen contours of major epicardial coronary arteries including their side branches. A step‐down reference diameter function was reconstructed based on the Murray bifurcation fractal law and used for QFR computation. Validation of this Murray law‐based QFR (μQFR) was performed on the FAVOR II China study population. The μQFR was computed separately in two angiographic projections, starting with the one with optimal angiographic image quality. Hemodynamically significant coronary stenosis was defined by pressure wire‐derived FFR ≤0.80. Results The μQFR was successfully computed in all 330 vessels of 306 patients. There was excellent correlation (r = 0.90, p < .001) and agreement (mean difference = 0.00 ± 0.05, p = .378) between μQFR and FFR. The vessel‐level diagnostic accuracy for μQFR to identify hemodynamically significant stenosis was 93.0% (95% CI: 90.3 to 95.8%), with sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio of 87.5% (95% CI: 80.2 to 92.8%), 96.2% (95% CI: 92.6 to 98.3%), 92.9% (95% CI: 86.5 to 96.9%), 93.1% (95% CI: 88.9 to 96.1%), 23.0 (95% CI: 11.6 to 45.5), 0.13 (95% CI: 0.08 to 0.20), respectively. Use of suboptimal angiographic image view slightly decreased the diagnostic accuracy of μQFR (AUC = 0.97 versus 0.92, difference = 0.05, p < .001). Intra‐ and inter‐observer variability for μQFR computation was 0.00 ± 0.03, and 0.00 ± 0.03, respectively. Average analysis time for μQFR was 67 ± 22 s. Conclusions Computation of μQFR from a single angiographic view has high feasibility and excellent diagnostic accuracy in identifying hemodynamically significant coronary stenosis. The short analysis time and good reproducibility of μQFR bear potential of wider adoption of physiological assessment in the catheterization laboratory.
Direct research on gut microbiota for understanding its role as 'an important organ' in human individuals is difficult owing to its vast diversity and host specificity as well as ethical concerns. Transplantation of human gut microbiota into surrogate hosts can significantly facilitate the research of human gut ecology, metabolism and immunity but rodents-based model provides results with low relevance to humans. A new human flora-associated (HFA) piglet model was hereby established taking advantage of the high similarity between pigs and humans with respect to the anatomy, physiology and metabolism of the digestive system. Piglets were delivered via cesarean section into a SPF-level barrier system and were inoculated orally with a whole fecal suspension from one healthy 10-year-old boy. The establishment and composition of the intestinal microbiota of the HFA piglets were analyzed and compared with that of the human donor using enterobacterial repetitive intergenic consensus sequence-PCR fingerprinting-based community DNA hybridization, group-specific PCR-temperature gradient gel electrophoresis and real-time PCR. Molecular profiling demonstrated that transplantation of gut microbiota from a human to germfree piglets produced a donor-like microbial community with minimal individual variation. And the microbial succession with aging of those ex-germfree piglets was also similar to that observed in humans. This HFA model provides a significantly improved system for research on gut ecology in human metabolism, nutrition and drug discovery.
Aims: A novel method for computation of fractional flow reserve (FFR) from optical coherence tomography (OCT) was developed recently. This study aimed to evaluate the diagnostic accuracy of a new OCTbased FFR (OFR) computational approach, using wire-based FFR as the reference standard.Methods and results: Patients who underwent both OCT and FFR prior to intervention were analysed.The lumen of the interrogated vessel and the ostia of the side branches were automatically delineated and used to compute OFR. Bifurcation fractal laws were applied to correct the change in reference lumen size due to the step-down phenomenon. OFR was compared with FFR, both using a cut-off value of 0.80 to define ischaemia. Computational analysis was performed in 125 vessels from 118 patients. Average FFR was 0.80±0.09. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value for OFR to identify FFR ≤0.80 was 90% (95% CI: 84-95), 87% (95% CI: 77-94), 92% (95% CI: 82-97), 92% (95% CI: 82-97), and 88% (95% CI: 77-95), respectively. The AUC was higher for OFR than minimal lumen area (0.93 [95% CI: 0.87-0.97] versus 0.80 [95% CI: 0.72-0.86], p=0.002). Average OFR analysis time was 55±23 seconds for each OCT pullback. Intra-and inter-observer variability in OFR analysis was 0.00±0.02 and 0.00±0.03, respectively. FFR fractional flow reserve IVUS intravascular ultrasound MLA minimal lumen area OCT optical coherence tomography OFR optical coherence tomography-based fractional flow reserve QFR quantitative flow ratio
Fractional flow reserve (FFR) and instantaneous wave-free ratio are the present standard diagnostic methods for invasive assessment of the functional significance of epicardial coronary stenosis. Despite the overall trend towards more physiology-guided revascularization, there remains a gap between guideline recommendations and the clinical adoption of functional evaluation of stenosis severity. A number of image-based approaches have been proposed to compute FFR without the use of pressure wire and induced hyperaemia. In order to better understand these emerging technologies, we sought to highlight the principles, diagnostic performance, clinical applications, practical aspects, and current challenges of computational physiology in the catheterization laboratory. Computational FFR has the potential to expand and facilitate the use of physiology for diagnosis, procedural guidance, and evaluation of therapies, with anticipated impact on resource utilization and patient outcomes.
Background: Ultrasonic flow ratio (UFR) is a novel method for fast computation of fractional flow reserve (FFR) from intravascular ultrasound images. The objective of this study is to evaluate the diagnostic performance of UFR using wire-based FFR as the reference. Methods: Post hoc computation of UFR was performed in consecutive patients with both intravascular ultrasound and FFR measurement in a core lab while the analysts were blinded to FFR. Results: A total of 167 paired comparisons between UFR and FFR from 94 patients were obtained. Median FFR was 0.80 (interquartile range, 0.68–0.89) and 50.3% had a FFR≤0.80. Median UFR was 0.81 (interquartile range, 0.69–0.91), and UFR showed strong correlation with FFR ( r =0.87; P <0.001). The area under the curve was higher for UFR than intravascular ultrasound-derived minimal lumen area (0.97 versus 0.89, P <0.001). The diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio for UFR to identify FFR≤0.80 was 92% (95% CI, 87–96), 91% (95% CI, 82–96), 96% (95% CI, 90–99), 96% (95% CI, 89–99), 91% (95% CI, 93–96), 25.0 (95% CI, 8.2–76.2), and 0.10 (95% CI, 0.05–0.20), respectively. The agreement between UFR and FFR was independent of lesion locations ( P =0.48), prior myocardial infarction ( P =0.29), and imaging catheters ( P =0.22). Intraobserver and interobserver variability of UFR analysis was 0.00±0.03 and 0.01±0.03, respectively. Median UFR analysis time was 102 (interquartile range, 87–122) seconds. Conclusions: UFR had a strong correlation and good agreement with FFR. The fast computational time and excellent analysis reproducibility of UFR bears the potential of a wider adoption of integration of coronary imaging and physiology in the catheterization laboratory.
Percutaneous coronary intervention (PCI) guided by coronary physiology provides symptomatic benefit and improves patient outcomes. Nevertheless, over one-fourth of patients still experience recurrent angina or major adverse cardiac events following the index procedure. Coronary angiography, the current workhorse for evaluating PCI efficacy, has limited ability to identify suboptimal PCI results. Accumulating evidence supports the usefulness of immediate post-procedural functional assessment. This review discusses the incidence and possible mechanisms behind a suboptimal physiology immediately after PCI. Furthermore, we summarize the current evidence base supporting the usefulness of immediate post-PCI functional assessment for evaluating PCI effectiveness, guiding PCI optimization, and predicting clinical outcomes. Multiple observational studies and post hoc analyses of datasets from randomized trials demonstrated that higher post-PCI functional results are associated with better clinical outcomes as well as a reduced rate of residual angina and repeat revascularization. As such, post-PCI functional assessment is anticipated to impact patient management, secondary prevention, and resource utilization. Pre-PCI physiological guidance has been shown to improve clinical outcomes and reduce health care costs. Whether similar benefits can be achieved using post-PCI physiological assessment requires evaluation in randomized clinical outcome trials.
BackgroundLactic acid sting test (LAST) is a classical method to identify sensitive skin. However, some subjects with self‐perceived sensitive skin are negative for LAST.ObjectiveTo determine whether LAST scores are associated with specific phenotype of sensitive skin.MethodsA total of 292 subjects with self‐perceived sensitive skin were enrolled in this study. The Sensitive Scale was used to evaluate the severity of burning, stinging, itching, tautness, erythema and scaling based on 0–10 scale scores. In addition to the assessment of LAST scores, epidermal biophysical properties were measured using an MPA system.ResultsThe Sensitive Scale scores of stinging, itching, tautness and scaling were significantly different between the LAST‐positive and ‐negative groups. However, burning and erythema scores did not differ between the LAST‐positive and ‐negative groups. LAST scores were positively correlated with the Sensitive Scale scores for stinging, itching, tautness and scaling, but not for burning and erythema scores. Moreover, LAST scores negatively correlated with stratum corneum hydration, but positively with transepidermal water loss (TEWL) rates.ConclusionsLactic acid sting test scores positively correlated with TEWL rates. LAST scores could be used to identify subjects with sensitive skin characterized mainly by stinging and itching, but not those mainly by burning and erythema.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers