Background: Screening and monitoring serum bilirubin (SBR) in neonates is crucial to prevent neonatal hyperbilirubinemia (NH)-associated morbidity and mortality worldwide. A lack of resources is often a barrier for measuring SBR in developing countries. Reliable, cost-effective, easy to use point-of-care (POC) SBR tests are needed. This study aimed to evaluate the technical accuracy and usability of the Bilistick System (BS), a new bilirubin POC test, in a tropical setting. Methods: This was a mixed-methods study, including laboratory validation of the BS, direct observation of technical procedures as performed by the midwives and midwives’ assessment of the device’s easiness of use through focus group discussions (FGD) and a self-administered questionnaire. The study was conducted in a field clinic of the Shoklo Malaria Research Unit along the Thailand-Myanmar border between January and December 2017. Results: A total of 173 samples were tested at a median age of 4 days. BS generated an error message—providing no SBR readout—in 48.6% of the tests performed. For the tests that yielded a result, the correlation coefficient (95% CI) between BS and routine laboratory bilirubinometer SBR was 0.87 (0.77-0.93). The accuracy decreased with increasing haematocrit and at higher humidity (≥75%). Direct observation of the operators using the device and analysis of the focus group discussions and questionnaires indicated that the BS was considered easy to use and required limited training. Conclusions: This evaluation showed that the BS, in its current formulation, does not provide reliable results for measuring SBR in a tropical, low-resource setting but has acceptable usability features.
Background: Screening and monitoring serum bilirubin (SBR) in neonates is crucial to prevent neonatal hyperbilirubinemia (NH)-associated morbidity and mortality worldwide. A lack of resources is often a barrier for measuring SBR in developing countries. Reliable, cost-effective, easy to use point-of-care (POC) SBR tests are needed. This study aimed to evaluate the technical accuracy and usability of the Bilistick System (BS), a new bilirubin POC test, in a tropical setting. Methods: This was a mixed-methods study, including laboratory validation of the BS, direct observation of technical procedures as performed by the midwives and midwives’ assessment of the device’s easiness of use through focus group discussions (FGD) and a self-administered questionnaire. The study was conducted in a field clinic of the Shoklo Malaria Research Unit along the Thailand-Myanmar border between January and December 2017. Results: A total of 173 samples were tested at a median age of 4 days. BS generated an error message—providing no SBR readout—in 48.6% of the tests performed. For the tests that yielded a result, the correlation coefficient (95% CI) between BS and routine laboratory bilirubinometer SBR was 0.87 (0.77-0.93). The accuracy decreased with increasing haematocrit and at higher humidity (≥75%). Direct observation of the operators using the device and analysis of the focus group discussions and questionnaires indicated that the BS was considered easy to use and required limited training. Conclusions: This evaluation showed that the BS, in its current formulation, does not provide reliable results for measuring SBR in a tropical, low-resource setting but has acceptable usability features.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.