Uninterruptible Power Supplies (UPSs) can be largely divided into the passive-standby, line-interactive and double-conversion methods. This paper proposes a double-conversion UPS with a low cost and high performance. This single phase UPS uses a single-loop robust voltage controller and 1-switch voltage doubler strategy PFC. The proposed UPS is composed of a single phase PFC, a half-bridge inverter, a battery charger and a battery discharger. Finally, the validity of proposed UPS was verified by various experimental tests.
-This paper describes the performance comparison results for current controller of a single-phase PFC converter with 1-switch voltage doubler strategy for single-phase double-conversion UPS(Uninterruptible Power Supply). A single-phase PFC converter with 1-switch voltage doubler strategy needs a diode bridge and one bidirectional active switch. Thus it is possible to reduce the material cost. However, the study results of current controller design and comparison of current control method has not been known after the converter circuit was proposed. For the performance comparison of current control, single-phase 3 kVA double-conversion UPS was tested. The performance of PI and PR current cotnroller is experimentally confirmed with followings -input current reference tracking, input power factor correction and input current THD suppression.
In this paper a robust voltage controller for a single-phase UPS inverter is newly presented. The voltage controller is designed using -based robust control scheme to simultaneously guarantee robust stability and robust tracking performance in the presence of load variations. Firstly the robust performance of the resulting controller is theoretically confirmed via -analysis. Then simulations and experiments for the single-phase inverter system with linear and nonlinear loads demonstrate feasibility of the proposed control method providing improved performance -good regulation and fast dynamic response.
-When the aspect ratio of a magnet varies, the magnetic field in the magnet also varies. The critical current of a tape-shaped HTS wire varies with the direction and magnitude of applied magnetic field. Consequently when the aspect ration of a HTS magnet varies, the critical current of a HTS magnet varies. This paper shows the relation between the aspect ratio of a magnet and the energy and inductance of a HTS magnet. The critical current is also shown at various aspect ratio of the magnet. The length of the HTS wire, inner diameter of the magnet, and number of pancake are chosen to be variables which varies the shape of the magnet. For a HTS magnet consisting of pancake windings, calculation results show the number of pancake windings are the prime factor which varied the energy and inductance of the magnet. The inner diameter of the magnet varies the energy and inductance of the magnet a little.
형상비에 따른 마그넷의 특성
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.