Preoperative factors associated with the visual outcome after macula-off rhegmatogenous retinal detachment surgery were the extent of detachment, macula-off duration, and external limiting membrane integrity. Postoperatively, predictive factors were the outer retinal microstructures, particularly the photoreceptor outer segment layer.
BackgroundTo report the radiological and clinical results after corrective osteotomy in ankylosing spondylitis patients. Furthermore, this study intended to classify the types of deformity and to suggest appropriate surgical treatment options.MethodsWe retrospectively analyzed ankylosing spondylitis patients who underwent corrective osteotomy between 1996 and 2009. The radiographic assessments included the sagittal vertical axis (SVA), spinopelvic alignment parameters, correction angle, correction loss, type of deformity related to the location of the apex, and the craniocervical range of motion (CCROM). The clinical outcomes were assessed by the Oswestry Disability Index (ODI) scores.ResultsA total of 292 corrective osteotomies were performed in 248 patients with a mean follow-up of 40.1 months (range, 24 to 78 months). There were 183 cases of single pedicle subtraction osteotomy (PSO), 19 cases of multiple Smith-Petersen osteotomy (SPO), 17 cases of PSO + SPO, 14 cases of single SPO, six cases of posterior vertebral column resection (PVCR), five cases of PSO + partial pedicle subtraction osteotomy (PPSO), and four cases of PPSO. The mean correction angles were 31.9° ± 11.7° with PSO, 14.3° ± 8.4° with SPO, 38.3° ± 12.7° with PVCR, and 19.3° ± 7.1° with PPSO. The thoracolumbar type was the most common. The outcome analysis showed a significant improvement in the ODI score (p < 0.05). Statistical analysis revealed that the ODI score improvements correlated significantly with the postoperative SVA and CCROM (p < 0.05). There was no correlation between the clinical outcomes and spinopelvic parameters. There were 38 surgery-related complications in 25 patients (10.1%).ConclusionsCorrective osteotomy is an effective method for treating a fixed kyphotic deformity occurring in ankylosing spondylitis, resulting in satisfactory outcomes with acceptable complications. The CCROM and postoperative SVA were important factors in determining the outcome.
Objective
Waist circumference (WC) is a widely accepted anthropometric parameter of central obesity. We investigated a fully automated body segmentation algorithm for measuring WC on abdominal computed tomography (CT) in comparison to manual WC measurements (WC-manual) and evaluated the performance of CT-measured WC for identifying overweight/obesity.
Materials and methods
This retrospective study included consecutive adults who underwent both abdominal CT scans and manual WC measurements at a health check-up between January 2013 and November 2019. Mid-waist WCs were automatically measured on noncontrast axial CT images using a deep learning-based body segmentation algorithm. The associations between CT-measured WC and WC-manual was assessed by Pearson correlation analysis and their agreement was assessed through Bland-Altman analysis. The performance of these WC measurements for identifying overweight/obesity (i.e., body mass index [BMI] ≥25 kg/m2) was evaluated using receiver operating characteristics (ROC) curve analysis.
Results
Among 763 subjects whose abdominal CT scans were analyzed using a fully automated body segmentation algorithm, CT-measured WCs were successfully obtained in 757 adults (326 women; mean age, 54.3 years; 64 women and 182 men with overweight/obesity). CT-measured WC was strongly correlated with WC-manual (r = 0.919, p < 0.001), and showed a mean difference of 6.1 cm with limits of agreement between -1.8 cm and 14.0 cm in comparison to WC-manual. For identifying overweight/obesity, CT-measured WC showed excellent performance, with areas under the ROC curve (AUCs) of 0.960 (95% CI, 0.933–0.979) in women and 0.909 (95% CI, 0.878–0.935) in men, which were comparable to WC-manual (AUCs of 0.965 [95% CI, 0.938–0.982] and 0.916 [95% CI, 0.886–0.941]; p = 0.735 and 0.437, respectively).
Conclusion
CT-measured WC using a fully automated body segmentation algorithm was closely correlated with manually-measured WC. While radiation issue may limit its general use, it can serve as an adjunctive output of abdominal CT scans to identify overweight/obesity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.