Transfer of six thin-layer chromatography (TLC) Global Pharma Health Fund Minilab kit protocols for detecting fake or markedly substandard drugs in pharmaceutical products in the field to quantitative high-performance TLC (HPTLC)–densitometry methods was carried out using a model process published earlier. The developed and validated methods for tablets or capsules containing cefixime, cefuroxime axetil, cephalexin·H2O, ciprofloxacin HCl, levofloxacin, and metronidazole involved use of EMD Millipore Premium Purity silica gel 60 F254 plates, automated sample and standard solution application with a CAMAG Linomat 4, and automated densitometry with a CAMAG Scanner 3 for detection, identification, and quantification.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.