Long‐term corrosion resistance of carbon steels grade API L80 and API Q125 has been evaluated by means of electrochemical measurements and exposure tests in the Molasse Basin, one of the most important geothermal fluids in Europe. In addition, the localized corrosion resistance of the duplex stainless steel alloy 2205 and the austenitic stainless steel grade 316L was determined at 100 and 150 °C. In general, investigated materials showed a remarkable resistance to uniform and localized corrosion. Their corrosion behaviour at service conditions is discussed in this paper.
Langzeitverhalten feuerverzinkter Stahlrohre 7 [19] W . Hiibner, E. Leitel, K. P. Thiessen: Schmierungstechnik 15 [25] V . S. Muralidharan, K. S. Rajagopalan: Electrochim. Acta 23 [20] J. O'M. Bockris, M. A . Genshaw, V . Brusil H. Wroblowa: Elec-[261 zum 60. Geburtstag gewidmet lOjahrige Dauerversuche an verzinkten Stahlrohren in Berliner Leitungswasser ergaben, daO ein beeintrachtigungsfreier Betrieb nur so lange gewahrleistet ist, wie sich metallisches Zink auf der Rohnvand befindet. Der zeitliche Verlauf des Zinkabtrags ist durch stetig abnehmende differentielle Korrosionsgeschwindigkeiten gekennzeichnet und la& sich durch eine logarithmische Funktion des Typsdarstellen, die eine starke pH-Abhangigkeit aufweist. Der typische VefIauf der logarithmischen Beziehung in Verbindung mit der pH-Abhangigkeit hat zur Folge, daf3 mit geringer pH-Anhebung eine iiberproportionale Verlangerung der Lebensdauer der metallischen Zinkschicht erreicht werden kann. Eine pH-Absenkung um eine halbe Einheit auf 7 fiihrt zu vollstandigem Zinkabtrag bereits nach ca. 2 Jahren, wahrend bei einer gleichartigen Erhohung auf pH = 8 nach 10 Jahren noch Restzinkschichten von 25-40 pm vorhanden sind, die einen weiteren jahrzehntelangen, ungestorten Betrieb envarten lassen.A 10 years' test program on galvanized steel tubes exposed to Berlin drinking water produced evidence that an undisturbed operation can only be guaranteed as long as the inner surface of the tubes is coated by metallic zinc. The zinc loss with time strongly depends on the pHvalue and can be expressed by the mathematical equation m = a . In(b t + 1).Due to the typical shape of the logarithmical function and its dependence on the pH-value a small increase of pH-value leads to an overproportional increase in life-time of the zinc coating. pH = 7 leads to a total zinc loss within two years, whereas in the case of pH = 8 a zinc coating of 25-40 pm is still present after 10 years' time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.