Currently, all agencies of conformity assessment testing laboratory favor the participation in proficiency testing as a mechanism for quality assurance. In Colombia, the Genes Laboratory has been designated, since 2008, to perform, design and implement proficiency testing for all the interested laboratories. In this report, the results of Colombian exercise Interlaboratory Quality Control for the year 2015 are presented. The exercise consisted of one practical component, one theoretical mandatory component, and an optional theoretical component. Twenty laboratories participated, representing six different countries of Latin America and the Caribbean. For the practical component each participant laboratory received; (1) samples of blood, saliva, and semen stains, in this part they should report the routine own laboratory markers for each sample, (2) three optional theoretical cases of varying complexity, (3) a mandatory theoretical approach about a biological relationship of paternal grandparentsgranddaughter case. In the last two components of the exercise, they had to submit only the calculations. For the practical component the consensus of 70 STR markers, distributed between autosomal and linked to the sex chromosomes, was achieved with an error rate of 0.80% in genotyping, 1.0% nomenclature and/or format discrepancies and 3.8% non-reporting. On the other hand, 99.4% of the reported values were correct, only two values were not correct (0.6%) but were within the range of 5% of the correct value, being acceptable values within the rules of the exercise. This inter-laboratory exercise has become an important mechanism for quality assurance and ongoing training in the region.
Currently, all agencies of conformity assessment testing laboratory favor the participation in proficiency testing as a mechanism for quality assurance. In Colombia, the Genes Laboratory has been designated, since 2008, to perform, design and implement the proficiency testing for all the interested laboratories. In this report, we show the results of Colombian exercises Inter-laboratory Quality Control for the years 2013 and 2014. In both years the exercise consisted in one practical component, one theoretical mandatory component and a theoretical optional component. The participants were 23 and 20 laboratories in 2013 and 2014, respectively, representing seven different countries of Latin America and the Caribbean. For the practical component each participant laboratory receive;(1) samples of blood, saliva and/or semen stains, in this part they should report the routine own laboratory markers for each sample, (2) three optional theoretical cases of varying complexity, (3) a simple theoretical approach consistent of paternity case (father, mother and son) (2013) and a complex paternity case with a deceased father (2014). In the last two components of the exercise they had to submit only the calculations. In both years, for the practical component the consensus of 70 STR markers, distributed between autosomal and linked to the sex chromosomes, was achieved with an error rate of 1.75% and 3.07% for 2013 and 2014, respectively. On the other hand, for mandatory theoretical exercise, error rates of 21.74% (2013) and 10.63% (2014) were detected. This inter-laboratory exercise has become an important mechanism for quality assurance in the region.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.