Methodology for PET system modeling using imagespace techniques in the expectation maximization (EM) algorithm is presented. The approach, applicable to both list-mode data and projection data, is of particular significance to EM algorithm implementations which otherwise only use basic system models (such as those which calculate the system matrix elements on the fly). A basic version of the proposed technique can be implemented using image-space convolution, in order to include resolution effects into the system matrix, so that the EM algorithm gradually recovers the modeled resolution with each update. The improved system mod-
eling (achieved by inclusion of two convolutions per iteration) results in both enhanced resolution and lower noise, and there is often no need for regularization-other than to limit the number of iterations. Tests have been performed with simulated list-mode data and also with measured projection data from a GE Advance PET scanner, for both [ 18 F]-FDG and [ 124 I]-NaI. The method demonstrates improved image quality in all cases when compared to the conventional FBP and EM methods presently used for clinical data (which do not include resolution modeling). The benefits of this approach for 124 I (which has a low positron yield and a large positron range, usually resulting in noisier and poorer resolution images) are particularly noticeable.Index Terms-Iterative image reconstruction, positron emission tomography (PET).
Because of the heterogeneity in tumor biology with respect to antibody uptake and clearance, we suggest that either intrapatient dose escalation approaches or larger, more precisely defined patient cohorts would be preferable to conventional strategies in the design of phase I studies with antiangiogenic compounds like HuMV833.
High-resolution three-dimensional (3-D) positron emission tomography (PET) scanners with high count rate performance, such as the quad-high density avalanche chamber (HIDAC), place new demands on image reconstruction algorithms due to the large quantities of high-precision list-mode data which are produced. Therefore, a reconstruction algorithm is required which can, in a practical time frame, reconstruct into very large image arrays (submillimeter voxels, which range over a large field of view) whilst preferably retaining the precision of the data. This work presents an algorithm which meets these demands: one-pass list-mode expectation maximization (OPL-EM) algorithm. The algorithm operates directly on list-mode data, passes through the data once only, accounts for finite resolution effects in the system model, and can also include regularization. The algorithm performs multiple image updates during its single pass through the list-mode data, corresponding to the number of subsets that the data have been split into. The algorithm has been assessed using list-mode data from a quad-HIDAC and is compared to the analytic reconstruction method 3-D reprojection (RP) with 3-D filtered backprojection.Index Terms-Iterative image reconstruction, list mode, positron emission tomography (PET).
The physical and radiochemical characteristics of the four copper isotopes make each more suited to some imaging tasks than others. The results presented here assist in selecting the preferred radioisotope for a given imaging application, and illustrate a strategy which can be extended to the majority of novel PET tracers.
We have previously shown that labelled water positron emission tomography (H2(15)O PET) can be used to identify regional cerebral blood flow (rCBF) changes in the human brain during volitional swallowing. (18F) fluorodeoxyglucose (FDG PET), by comparison, uses a glucose analogue to quantitatively measure regional cerebral glucose metabolism (rCMRglc) rather than rCBF. The main advantage of FDG PET is improved spatial resolution, and because of its pharmacodynamic properties, activation can be performed external to the scanner, allowing subjects to assume more physiologic positions. We therefore conducted a study of the brain's metabolic response while swallowing in the erect seated position, using FDG PET. Eight healthy male volunteers were studied with a randomised 2 scan paradigm of rest or water swallowing at 20-second intervals for 30 minutes. Data were analysed with SPM99 using multisubject conditions and covariates design. During swallowing, analysis identified increased rCMRglc (P<0.01) in the following areas: left sensorimotor cortex, cerebellum, thalamus, precuneus, anterior insula, left and right lateral postcentral gyrus, and left and right occipital cortex. Decreased rCMRglc were also seen in the right premotor cortex, right and left sensory and motor association cortices, left posterior insula and left cerebellum. Thus, FDG PET can be applied to measure the brain metabolic activity associated with volitional swallowing and has the advantage of normal task engagement. This has implications for future activation studies in patients, especially those suffering swallowing problems after brain injury.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.