The geometric phase analysis (GPA) algorithm is known as a robust and straightforward technique that can be used to measure lattice strains in high resolution transmission electron microscope (TEM) images. It is also attractive for analysis of aberration-corrected scanning TEM (ac-STEM) images that resolve every atom column, since it uses Fourier transforms and does not require real-space peak detection and assignment to appropriate sublattices. Here it is demonstrated that in ac-STEM images of compound materials (i.e. with more than one atom per unit cell) an additional phase is present in the Fourier transform. If the structure changes from one area to another in the image (e.g. across an interface), the change in this additional phase will appear as a strain in conventional GPA, even if there is no lattice strain. Strategies to avoid this pitfall are outlined.
Stable ultrashort light pulses and frequency combs generated by mode-locked lasers have many important applications including high-resolution spectroscopy, fast chemical detection and identification, studies of ultrafast processes, and laser metrology. While compact mode-locked lasers emitting in the visible and near infrared range have revolutionized photonic technologies, the systems operating in the mid-infrared range where most gases have their strong absorption lines, are bulky and expensive and rely on nonlinear frequency down-conversion. Quantum cascade lasers are the most powerful and versatile compact light sources in the mid-infrared range, yet achieving their mode-locked operation remains a challenge, despite dedicated effort. Here we report the demonstration of active mode locking of an external-cavity quantum cascade laser. The laser operates in the mode-locked regime at room temperature and over the full dynamic range of injection currents.
The In0.53Ga0.47As∕AlAs0.56Sb0.44 heterostructure system is of significant interest for the development of high-performance intersubband devices due to its very large conduction band offset (ΔEc∼1.6eV) and lattice-matched compatibility with well-established InP-based waveguide technology. In this letter, we report the realization of In0.53Ga0.47As∕AlAs0.56Sb0.44 quantum cascade lasers emitting at λ∼4.3μm. The highest-performance devices have low-temperature (20K) threshold currents of ∼6kA∕cm2 and display laser action up to a maximum temperature of 240K, with a characteristic temperature of T0∼150K.
Interest in mid-infrared spectroscopy instrumentation beyond classical FTIR using a thermal light source has increased dramatically in recent years. Synchrotron, supercontinuum, and external-cavity quantum cascade laser light sources are emerging as viable alternatives to the traditional thermal black-body emitter (Globar), especially for remote interrogation of samples ("stand-off" detection) and for hyperspectral imaging at diffraction-limited spatial resolution ("microspectroscopy"). It is thus timely to rigorously consider the relative merits of these different light sources for such applications. We study the theoretical maximum achievable signal-to-noise ratio (SNR) of FTIR using synchrotron or supercontinuum light vs. that of a tunable quantum cascade laser, by reinterpreting an important result that is well known in near-infrared optical coherence tomography imaging. We rigorously show that mid-infrared spectra can be acquired up to 1000 times fasterusing the same detected light intensity, the same detector noise level, and without loss of SNR-using the tunable quantum cascade laser as compared with the FTIR approach using synchrotron or supercontinuum light. We experimentally demonstrate the effect using a novel, rapidly tunable quantum cascade laser that acquires spectra at rates of up to 400 per second. We also estimate the maximum potential spectral acquisition rate of our prototype system to be 100,000 per second.
Strain compensated In0.67Ga0.33As/AlAs0.8Sb0.2/InP quantum cascade lasers emitting at wavelengths near 3.1 μm at room temperature have been demonstrated. The lasers operate in pulsed mode with threshold current density of 3.6 kA/cm2 at 80 K and 19.2 kA/cm2 at 295 K. The peak optical power for an as-cleaved 3 mm long and 10 μm wide ridge device exceeds 1 W per facet at 80 K and is around 8 mW at 295 K. The observed laser performance suggests that room temperature operation for these lasers remains possible beyond the predicted threshold for Γ-L intervalley scattering of electrons in the upper laser levels.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.