BackgroundSorafenib is the standard first-line therapy for hepatocellular carcinoma (HCC) and probably ectopic hepatocellular carcinoma (EHCC) as well. No report involves a side effect of delayed high fever of sorafenib. This manuscript describes a case of EHCC in the thoracic and abdominal cavities, who showed a delayed high fever and maculopapules during sorafenib treatment.Case presentationThe patient is a 63-year-old Chinese male with advanced EHCC, taking sorafenib 400 mg twice daily. On the tenth day, red maculopapules appeared all over the body. On the same day, the patient began to suffer from continuous high fever. Due to these effects, the patient was asked to cease sorafenib treatment, and the high fever and maculopapules were alleviated quickly. However, the symptoms were present again upon re-challenge of sorafenib. Prednisone was then administered to control the symptoms, with the dosage gradually reduced from 30 to 5 mg/day in 1.5 months. No recurrence of fever or maculopapules has been found. Tumor response reached partial response (PR) and progression free survival (PFS) reached 392 days + by the date of Apr. 14th, 2016.ConclusionEHCC could be treated like orthotopic HCC by oral administration of sorafenib, which shows good tumor response and survival benefit. Delayed high fever and maculopapules are potential, rare and severe side effects of sorafenib, and could be effectively controlled by glucocorticoid.
Intraoperative radiotherapy (IORT) has been used to treat different residual solid tumors after tumor removal and has shown many advantages over other treatment methods. However, the use of IORT for invasive thymoma has not been reported. Therefore, in this study, we tried to determine the safety and efficacy of INTRABEAM IORT for the treatment of invasive thymoma. Among the patients admitted to our hospital from September to December 2016 who were diagnosed with invasive thymoma, 14 were selected as study subjects. With medical histories taken beforehand, 8 of these patients were diagnosed with Masaoka stage IIA and 6 with Masaoka stage IIB; furthermore, 5 of the patients were diagnosed with myasthenia gravis (MG). INTRABEAM radiation (8–10 Gy, low energy) was delivered to the postoperative tumor bed of each patient during surgery. The intra- and postoperative complications were observed and evaluated, and the improvement in symptoms was assessed. An additional 23 patients with stage II thymoma undergoing radical surgery from April to August 2016 were chosen as the control group. One month after the operation, only 1 patient in the IORT group had cough, increased levels of leucocytes and neutrophils, and pulmonary inflammation on chest computed tomography. Reactive inflammation and pleural effusion in the 2 groups were similar ( P > .05). There was no significant difference between the 2 groups in the improvement of myasthenia gravis ( P > .05). Postoperative chest computed tomography and routine blood examination at 3 and 12 months showed that all the patients recovered, with normal hemogram levels and no pulmonary fibrosis around the radiation field. In addition, ultrasonic cardiography and electrocardiography demonstrated no significant difference before or after surgery within the IORT group. At the end of the follow-up, all the patients were alive, no relapse or remote metastasis was observed in the IORT group, and 2 inpatients in the control group had experienced relapse at 24 and 26 months. There was a significant difference in disease-free survival between the 2 groups ( P = .00). It is safe to administer low-energy INTRABEAM IORT at a dose of approximately 10 Gy in patients with stage II invasive thymoma. INTRABEAM IORT does not significantly increase operation- or radiation-related complications and has no significant effect on vital organs such as the lungs and heart. Its long-term efficacy is worth expecting.
The aim of the present study was to investigate the optimal strategy and dosimetric measurement of thoracic radiotherapy based on three-dimensional (3D) modeling of mediastinal lymph nodes (MLNs). A 3D model of MLNs was constructed from a Chinese Visible Human female dataset. Image registration and fusion between reconstructed MLNs and original chest computed tomography (CT) images was conducted in the Eclipse™ treatment planning system (TPS). There were three plans, including 3D conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), which were designed based on 10 cases of simulated lung lesions (SLLs) and MLNs. The quality of these plans was evaluated via examining indexes, including conformity index (CI), homogeneity index and clinical target volume (CTV) coverage. Dose-volume histogram analysis was performed on SLL, MLNs and organs at risk (OARs). A Chengdu Dosimetric Phantom (CDP) was then drilled at specific MLNs according to 20 patients with thoracic tumors and of a medium-build. These plans were repeated on fused MLNs and CDP CT images in the Eclipse™ TPS. Radiation doses at the SLLs and MLNs of the CDP were measured and compared with calculated doses. The established 3D MLN model demonstrated the spatial location of MLNs and adjacent structures. Precise image registration and fusion were conducted between reconstructed MLNs and the original chest CT or CDP CT images. IMRT demonstrated greater values in CI, CTV coverage and OAR (lungs and spinal cord) protection, compared with 3D-CRT and VMAT (P<0.05). The deviation between the measured and calculated doses was within ± 10% at SLL, and at the 2R and 7th MLN stations. In conclusion, the 3D MLN model can benefit plan optimization and dosimetric measurement of thoracic radiotherapy, and when combined with CDP, it may provide a tool for clinical dosimetric monitoring.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.