Objective: To evaluate the diagnostic performance of computed tomography (CT) fluoroscopy-guided percutaneous transthoracic needle biopsy (PTNB) in pulmonary nodules ≤ 10 mm during the coronavirus disease 2019 pandemic. Materials and Methods: Between January 1, 2020 and April 30, 2022, a total of 359 CT fluoroscopy-guided PTNBs were performed at an interventional radiology center. Lung lesions measured between 2 mm and 108 mm. Of the 359 PTNBs, 27 (7.5%) were performed with an 18G core needle on nodules ≤ 10 mm in diameter. Results: Among the 27 biopsies performed on nodules ≤ 10 mm, the lesions measured < 5 mm in four and 5-10 mm in 23. The sensitivity and overall diagnostic accuracy of PTNB were 100% and 92.3%, respectively. The mean dose of ionizing radiation during PTNB was 581.33 mGy*cm (range, 303-1,129 mGy*cm), and the mean biopsy procedure time was 6.6 min (range, 2-12 min). There were no major postprocedural complications. Conclusion: CT fluoroscopy-guided PTNB appears to provide a high diagnostic yield with low complication rates.
Resumo Objetivo: Avaliar o desempenho diagnóstico da biópsia pulmonar percutânea transtorácica (BPPT) guiada por fluoroscopia associada a tomografia computadorizada (FTC) em nódulos pulmonares ≤ 10 mm no período de pandemia de COVID-19. Materiais e Métodos: No período de 1º de janeiro de 2020 a 30 de abril de 2022, 359 BPPTs guiadas por FTC foram realizadas em um centro terciário de radiologia intervencionista. As lesões pulmonares mediam entre 2 mm e 108 mm. Dessas 359 BPPTs, 27 (7,5%) foram realizadas com agulha 18G em nódulos de 2 mm a 10 mm. Resultados: Das 27 BPPTs realizadas nos nódulos ≤ 10 mm, quatro lesões tinham dimensões menores que 5 mm e 23 lesões mediam entre 5 e 10 mm. Sensibilidade e acurácia diagnóstica das BPPTs guiadas por FTC foram de 100% e 92,3%, respectivamente. A dose média de radiação ionizante para os pacientes durante o procedimento de BPPT guiada por FTC foi de 581,33 mGy*cm, variando de 303 a 1129 mGy*cm. A média de tempo dos procedimentos de biópsia foi de 6,6 minutos, variando de 2 a 12 minutos. Nas 27 BPPTs, nenhuma complicação maior foi descrita. Conclusão: A BBPT guiada por FTC resultou em alto rendimento diagnóstico e baixas taxas de complicações.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.