A spectroscopic detection system for the accurate monitoring of carbon dioxide (CO 2 ) in exhaled breath was realized by tunable diode laser absorption spectroscopy (TDLAS) in conjunction with a vertical-cavity surface-emitting laser (VCSEL) and a multipass cell with an effective optical path-length of 20 m. The VCSEL diode emitting light with an output power of 0.8 mW, covered the strong absorption line of CO 2 at 6330.82 cm −1 by drive-current tuning. The minimum detectable concentration of 0.769% for CO 2 detection was obtained, and a measurement precision of approximately 100 ppm was achieved with an integration time of 168 s. Real-time online measurements were carried out for the detection of CO 2 expirograms from healthy subjects, different concentrations were obtained in dead space and alveolar gas. The exhaled CO 2 increased significantly with the increasing physical activity, reaches its maximal value at the beginning of respiratory compensation and then decreased slightly until maximal exercise. The developed measurement system has a great potential to be applied in practice for the detection of pulmonary diseases associated with CO 2 retention.
The center of plantar pressure (COP) reflects the dynamic balance of subjects to a certain extent. In this study, wearable pressure insoles are designed, body pose measure is detected by the Kinect sensor, and a balance evaluation system is formulated. With the designed games for the interactive actions, the Kinect sensor reads the skeletal poses to judge whether the desired action is performed, and the pressure insoles simultaneously collect the plantar pressure data. The COP displacement and its speed are calculated to determine the body sway and the ability of balance control. Significant differences in the dispersion of the COP distribution of the 12 subjects have been obtained, indicating different balancing abilities of the examined subjects. A novel assessment process is also proposed in the paper, in which a correlation analysis is made between the de facto sit-to-stand (STS) test and the proposed method; the Pearson and Spearman correlations are also conducted, which reveal a significant positive correlation. Finally, four undergraduate volunteers with a right leg sports injury participate in the experiments. The experimental results show that the normal side and abnormal side have significantly different characters, suggesting that our method is effective and robust for balance measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.