Background: Point-of-care haemoglobin meters are attractive solutions to improve timely diagnosis of anaemia in resource-limited settings. However, concerns regarding the accuracy of these meters may affect their adoption. The accuracy of two hand-held point-of-care haemoglobin meters was evaluated against reference full blood count analyser. Methods: This was a hospital-based cross-sectional study conducted at the Douala General hospital, Cameroon. Two handheld haemoglobin meters were assessed: Urit12® (URIT Medical Electronics Co.,Ltd. Guangxi, China) and MissionHb®(ACON Laboratories, Inc., San Diego, USA); against a reference standard CELL-DYN RUBY® (ABBOTT DIAGNOSTICS, Illinois, USA). The Pearson's correlation and Bland-Altman agreement were used to assess the technical accuracy of the meters. Clinical accuracy was evaluated using total error allowable and area under the Receiver Operating Curve. Finally, their agreement with the reference in diagnosing anaemia was assessed using the kappa statistic. Results: A total of 228 participants were included in the study. The mean haemoglobin values of both haemoglobin meters (MissionHb®: 11.6 ± 2.5 g/dl; Urit12®: 10.9 ± 2.7 g/dl) were significantly higher than the reference value (10.5 ± 2.5 g/dl), p < 0.001 for both meters. Both haemoglobin meters had good correlation with the reference analyser (r = 0.89 and r = 0.90 for Urit12® and MissionHb® respectively) and good agreement on the Bland-Altman plots. However, the MissionHb® meter did not meet the clinical accuracy requirements (p < 0.001). Even though both meters were excellent at identifying the presence of anemia (MissionHb®-AUC = 0.9161, Urit 12®-AUC = 0.9009), they, however, both had weak agreement with the reference analyser in diagnosing the severity of anaemia (K = 0.39 for MissionHb®, p < 0.001 and K = 0.54 for Urit12®, p < 0.001). Conclusion: Although both devices showed technical accuracy with a positive correlation with the reference analyser and were able to accurately diagnose the presence of anemia, both meters however, had sub-optimal agreement with the reference analyser in diagnosing the degree of severity of anaemia among our participants.
The Faces Pain Scale-Revised (FPS-R) is a self-report pain scale validated in numerous countries, but not in Cameroon. We postulated that while cultural factors influence pain perception and expression, the FPS-R should remain culturally acceptable for pediatric use. A convenience sample of 36 pediatric patients, aged 4 to 16 years, representing three primary language groups, was enrolled at Mbingo Baptist Hospital (MBH). Pre- and postanalgesia FPS-R scores and vital signs were obtained. Audio-recorded cognitive interviews were performed with each participant. Written questionnaires were also provided to physicians, nurses, and caretakers to further explore cultural perceptions of pain. Four independent reviewers analyzed interview transcripts and questionnaires using inductive reasoning and identified common themes pertaining to gender differences, societal roles, and pain perception. Basic comprehension of the FPS-R was present across language groups, vital sign changes corresponded with FPS-R alterations, and the FPS-R appears intuitive for pediatric use.
Introduction capillary glucose measurement using point-of-care glucometers is an essential part of diabetes care. We determined the technical accuracy, clinical accuracy and precision of commonly available glucometers against standard spectrophotometry in Cameroon. Methods a sample of four glucometers was selected. In the 108 diabetic and non-diabetic participants, blood glucose values obtained by glucometers were compared to the reference laboratory method to determine their technical and clinical accuracies. Precision was determined by repeated measurements using standard solutions of different concentrations. Results accu-Chek ® Active, CodeFree™, Mylife™ Pura™ and OneTouch ® Ultra ® 2 values had correlation coefficients of 0.96, 0.87, 0.97 and 0.94 respectively with reference values, and biases of 18.7%, 29.1%, 16.1% and 13.8% respectively. All glucometers had ≥ 95% of values located within the confidence limits except OneTouch ® Ultra ® 2. Accu-Chek ® Active, CodeFree™, Mylife™ Pura™ and OneTouch ® Ultra ® 2 had 99%, 93.1%, 100% and 98.0% of values in Parke's zones A and B. The coefficients of variation of the glucometers were all below 5% at all standard concentrations, except for Accu-Chek ® Active for glucose concentrations at100 and 200mg/dL. Conclusion no glucometer met all the international recommendations for technical accuracy. Accu-Chek™ Active and Mylife™, Pura™ met the International Organization for Standardization 2013 recommendations for clinical accuracy based on Parke's consensus error grid analysis. All glucometers assessed except Accu-Chek ® Active showed a satisfactory level of precision at all concentrations of standard solutions used.
To attain the HIV 95-95-95 goals by 2030 in Cameroon, high quality research to inform policy and patient care is of utmost importance. In the context of limited workforce and resources, collaborations, sharing of locally-adapted strategies and other field experience, leveraging on existing and innovative platforms would facilitate a coordinated and optimal AIDS response at country level. The second edition of the Cameroon HIV Research Forum (CAM-HERO) conference took place both physically and virtually on November 18 and 19, 2021 in Kribi, on the theme “Research for Policy and Care”. This scientific event brought together Cameroonian HIV/AIDS researchers, experienced clinicians and regulatory authorities to foster i) the dissemination of research findings and facilitate translation into policy, ii) operational research collaboration, iii) identification of new research areas, and iv) capacity building. To achieve the set objectives during this event, a consensus on research priorities for accelerating the achievement of three 95 HIV goals in Cameroon were summarized; meeting sessions included 31 abstract presentations, 13 discussions, and presentations on various aspects of HIV research including ethics, administrative procedures and needs for capacity building; training of young scientists on guidelines for research proposal development toward ethical clearance was done; and a platform for discussion between researchers and regulatory authorities was conducted around the design and setting-up of a national HIV/AIDS research agenda. CAM-HERO 2021 brought together HIV researchers, experts and junior scientists around major programmatic challenges, evidence to translate into practice, research priorities on HIV/AIDS. Collaborations were reinforced, capacities were strengthened, and footprints were established towards a consensus on a national HIV/AIDS research agenda.
Background Hospital-acquired complications (HACs) contribute to increased morbidity, mortality and hospital costs. However, their burden is often overlooked in resource-limited settings. We sought to determine the incidence, risk factors and effects of HACs on direct medical costs. Methods This was a prospective cohort study conducted in the Internal Medicine inpatient ward of Douala General Hospital over 3 mo. Patients were examined daily from admission to discharge, transfer or death. Incidence of HACs was calculated and risk factors of HACs were determined using univariate and multivariate regression models. Results The cumulative incidence rate of HACs in 230 participants was 29.2/1000 patient-days. The incidence rate of infectious and non-infectious complications was 8.4/1000 and 20.9/1000 patient-days, respectively. The most common HAC was constipation (8.3/1000 patient-days). The most common infection was urinary tract infection (3.7/1000 patient-days). HIV infection and length of stay >8 d were significantly associated with the occurrence of HACs. Deep vein thrombosis was associated with the highest direct medical cost. Conclusion The incidence of HACs is high in our setting and leads to increased length of hospital stays as well as greater direct medical costs. Thus, there is a need for effective preventive strategies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.