BackgroundIncreased spatial QRS-T angle has been shown to predict appropriate implantable cardioverter defibrilIator (ICD) therapy in patients with left ventricular systolic dysfunction (LVSD). We performed a retrospective cohort study in patients with left ventricular ejection fraction (LVEF) 31–40% to assess the relationship between the spatial QRS-T angle and other advanced ECG (A-ECG) as well as echocardiographic metadata, with all-cause mortality or ICD implantation for secondary prevention.Methods534 patients ≤75 years of age with LVEF 31–40% were identified through an echocardiography reporting database. Digital 12-lead ECGs were retrospectively matched to 295 of these patients, for whom echocardiographic and A-ECG metadata were then generated. Data mining was applied to discover novel ECG and echocardiographic markers of risk. Machine learning was used to develop a model to predict possible outcomes.Results49 patients (17%) had events, defined as either mortality (n = 16) or ICD implantation for secondary prevention (n = 33). 72 parameters (58 A-ECG, 14 echocardiographic) were univariately different (p<0.05) in those with vs. without events. After adjustment for multiplicity, 24 A-ECG parameters and 3 echocardiographic parameters remained different (p<2x10-3). These included the posterior-to-leftward QRS loop ratio from the derived vectorcardiographic horizontal plane (previously associated with pulmonary artery pressure, p = 2x10-6); spatial mean QRS-T angle (134 vs. 112°, p = 1.6x10-4); various repolarisation vectors; and a previously described 5-parameter A-ECG score for LVSD (p = 4x10-6) that also correlated with echocardiographic global longitudinal strain (R2 = - 0.51, P < 0.0001). A spatial QRS-T angle >110° had an adjusted HR of 3.4 (95% CI 1.6 to 7.4) for secondary ICD implantation or all-cause death and adjusted HR of 4.1 (95% CI 1.2 to 13.9) for future heart failure admission. There was a loss of complexity between A-ECG and echocardiographic variables with an increasing degree of disease.ConclusionSpatial QRS-T angle >110° was strongly associated with arrhythmic events and all-cause death. Deep analysis of global ECG and echocardiographic metadata revealed underlying relationships, which otherwise would not have been appreciated. Delivered at scale such techniques may prove useful in clinical decision making in the future.
Aim.-Plasma levels of certain ceramides are increased in patients with ischemic heart disease (IHD). Many risk factors for IHD are also risk factors for chronic kidney disease (CKD), but it is currently uncertain whether plasma ceramide levels are increased in patients with CKD. Methods.-We measured six previously identified high-risk plasma ceramide concentrations
Distinct plasma ceramides are positive and independent predictors of stress-induced myocardial perfusion defects in patients with established or suspected CAD referred for clinically indicated MPS. Further research is needed to examine whether distinct plasma ceramides could be a useful therapeutic target for treatment and management of CAD.
Aim: Recent prospective studies have identified distinct plasma ceramides as strong predictors of major adverse cardiovascular events in patients with established or suspected coronary artery disease (CAD). Currently, it is uncertain whether higher levels of distinct plasma ceramides are also associated with greater angiographic severity of coronary-artery stenoses in this patient population. Methods: We measured six previously identified high-risk plasma ceramide species
Objective—
It is known that specific plasma ceramides are associated with stress-induced reversible myocardial perfusion defects in patients with established or suspected coronary artery disease undergoing myocardial perfusion scintigraphy (MPS). However, it is currently uncertain whether plasma ceramides are also associated with reduced poststress myocardial perfusion in these patients.
Approach and Results—
We measured 6 previously identified high-risk plasma ceramide species (ceramide [d18:1/16:0], ceramide [d18:1/18:0], ceramide [d18:1/20:0], ceramide [d18:1/22:0], ceramide [d18:1/24:0], and ceramide [d18:1/24:1]) in 167 consecutive patients with established or suspected coronary artery disease undergoing stress MPS for clinical indications. Plasma ceramides were measured by a targeted liquid chromatography–tandem mass spectrometry assay both at baseline and after MPS. Multivariable linear regression analysis was undertaken to examine the associations (standardized B coefficients) between plasma ceramides and the percentage of poststress myocardial perfusion after adjustment for multiple cardiovascular risk factors. Seventy-eight patients had stress-induced myocardial ischemia on MPS (mainly located in the anteroapical wall). Of the 6 measured plasma ceramides, higher levels of basal ceramide (d18:1/18:0; B=−0.182;
P
=0.019), ceramide (d18:1/20:0; B=−0.224;
P
=0.004), ceramide (d18:1/22:0; B=−0.163;
P
=0.035), and ceramide (d18:1/24:1; B=−0.20;
P
=0.010) were associated with lower poststress anteroapical wall perfusion. Notably, these significant associations persisted even after adjustment for conventional cardiovascular risk factors, previous coronary artery disease, electrocardiographic left bundle branch block, left ventricular ejection fraction and type of stress testing. Similar results were observed for poststress plasma ceramides.
Conclusions—
Higher circulating levels of specific ceramides, both at baseline and after stress, were independently associated with lower poststress anteroapical wall perfusion in patients with suspected or established coronary artery disease referred for clinically indicated MPS.
This study shows for the first time that hyperuricemia is independently associated with an approximately fourfold increased risk of prevalent paroxysmal AF in patients with T2DM. These findings may partly explain the increased risk of permanent atrial fibrillation and cardiovascular death observed among patients with hyperuricemia.
ICD in patients with ARVC has been demonstrated to be feasible and safe. In our case series, we found low R-wave amplitudes at implantation and a significant R-wave decrease during follow-up; a considerable and nearly significant increase in pacing threshold was also observed. These findings may be related to the progressive fibro-fatty replacement of RV myocardium. Multiple sites should be tested in the right ventricle if sensing or pacing values are not optimal, and all the electronic parameters should be carefully monitored throughout the entire follow-up.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.