The effects of microwave irradiation at two different frequencies (1.28 and 5.62 GHz) on observing-behavior of rodents were investigated. During daily irradiation, eight male hooded rats performed on a two-lever task; depression of one lever produced one of two different tones and the other lever produced food when depressed in the presence of the appropriate tone. At 5.62 GHz, the observing-response rate was not consistently affected until the power density approximated 26 mW/cm2 at 1.28 GHz, the observing-response rate of all rats was consistently affected at a power density of 15 mW/cm2. The respective whole-body specific absorption rates (SARs) were 4.94 and 3.75 W/kg. Measurements of localized SAR in a rat-shaped model of simulated muscle tissue revealed marked differences in the absorption pattern between the two frequencies. The localized SAR in the model's head at 1.28 GHz was higher on the side distal to the source of radiation. At 5.62 GHz the localized SAR in the head was higher on the proximal side. It is concluded that the rat's observing behavior is disrupted at a lower power density at 1.28 than at 5.62 GHz because of deeper penetration of energy at the lower frequency, and because of frequency-dependent differences in anatomic distribution of the absorbed microwave energy.
A 275-MHz exposure system, consisting of a circular waveguide irradiator and a transparent plastic animal cage, has been developed to accommodate rhesus monkeys weighing up to 15 kg. The vertically oriented waveguide is composed primarily of stainless steel and is fitted with an inner cage fabricated from a tubular section of acrylic plastic. Circularly polarized electromagnetic energy at 275 MHz, either pulsed or continuous wave (CW), can be propagated from the removable top section of the waveguide. The cage is designed to function as the monkey's permanent home. It is fitted with a lever-actuated behavioral performance device on which the monkey responds according to a predetermined schedule to obtain a daily food ration. The system can be adapted to provide for the collection of metabolic and physiologic data as well. Dosimetric measurements were conducted with six rhesus monkeys weighing 3.0-7.2 kg and with a 4-kg model. The dosimetric results show that about one-third of the net incident energy is absorbed by a subject in this system at a normalized specific absorption rate (SAR) of 0.33 (W/kg)/(mW/cm2).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.