Background: Nowadays, ICRS are a step in the treatment of keratoconus. The purpose of this study was to evaluate the refractive effect and the tomographic and biomechanical parameters in keratoconus patients implanted with Ferrara ICRS, and their stability after 18 months. Materials and methods:Twenty eyes of 20 keratoconus patients implanted with ICRS were evaluated. The average follow-up was 18 months. UDVA, CDVA, biomicroscopy, tomography (Pentacam) and biomechanics (ORA) of the cornea were evaluated before and after surgery. For the comparison of groups, the Wilcoxon test was used. Results:The mean UDVA improved from 1.00 to 0.30 and the mean CDVA improved from 0.51 to 0.12; both were statistically significant (p = 0.0001). The average keratometry decreased from 50.7D to 47.5D (p = 0.0003), and the average astigmatism decreased from 5.5D to 3.5D (p = 0.0058). The mean CCT did not change significantly after surgery, but the mean TPP increased from 441.2 to 455.2 µm (p = 0.004). There was a significant reduction in the anterior cornea elevation, both the central (from 16.2-8.8; p = 0.0066) and the minimum (from -43.2 to -57.1; p = 0.0228). No significant change was found for posterior corneal elevation and for biomechanical parameters (hysteresis or CRF). Discussion:There was a significant improvement of UDVA and CDVA after ICRS implantation, in keratoconic eyes. There was a significant and stable corneal flattening, and a decrease of the astigmatism. Corneal biomechanic parameters did not change.
; Guillermo Coca Velarde 5 RESUMO Objetivo: Verificar os resultados da cirurgia de implante de segmentos de anel estromal para ceratocone e as possíveis correlações existentes entre o resultado cirúrgico e o estado biomecânico da córnea no pré-operatório. Métodos: Dezenove olhos de 19 pacientes com ceratocone foram avaliados antes e 12 meses após a cirurgia de implante de segmento anel estromal. O implante de um ou dois segmentos de anel de Ferrara foi realizado de acordo com o nomograma, considerando-se espessura da córnea, padrão topográfico da ectasia e o astigmatismo. O teste de Wilcoxon signed rank foi realizado para verificar diferenças entre a acuidade visual (logMAR) corrigida com óculos antes da cirurgia (AVccPré) e a obtida sem correção (AVscPós) e com correção (AVccPós) após a cirurgia, bem como entre os valores pré e pós-operatórios de variáveis tomográficas medidas com o Pentacam e variáveis biomecânicas da córnea medidas com o ORA (ocular response analyzer). As diferenças absolutas antes e após a cirurgia (valores delta -Δ) das variáveis com diferenças significantes foram calculadas. Os valores Δ foram correlacionados com as medidas do ORA no pré-operatório por meio dos testes de Pearson ou de Spaerman, de acordo com a distribuição das variáveis ser normal ou não (teste de Kolmogorov-Smirnov). Resultados: Observou-se melhora significante na AVcc, bem como na AVscPós em comparação com a AVccPré (teste de Wilcoxon, p<0,05). Houve redução significativa do astigmatismo ceratométrico (AST), dos valores ceratométricos centrais (K1 e K2), do valor ceratométrico mais elevado (KMáx) e dos índices CKI (índice de severidade do ceratocone -center keratoconus index ), IHD (índice de descentração da elevação -index of height decentration) e ISV (índice de variação da superfície -index of surface variance) após a cirurgia (teste de Wilcoxon, p<0,05). Observou-se um significativo aumento da espessura corneana a 3,8 e a 4mm do ápice em direção temporal no meridiano horizontal, bem como houve deslocamento inferior significativo da posição do KMáx (teste de Wilcoxon, p<0,05). Nenhuma variável biomecânica apresentou diferença estatisticamente significante após a cirurgia (teste de Wilcoxon, p>0,05). Os parâmetros do ORA derivados das pressões de aplanamento: histerese da córnea (corneal hysteresis -CH), fator de resistência da córnea (corneal resistance factor -CRF) e as medidas da pressão ocular (IOPg e IOPcc) não apresentaram correlações significantes com os parâmetros delta (Δ). Quinze das 38 variáveis biomecânicas derivadas do sinal de reflexo da córnea do ORA apresentaram correlação significante com pelo menos um parâmetro Δ, destacando-se as correlações entre o ΔKMáx com aindex e path1 (teste de Pearson, p<0,05; r=-0,56 e 0,56 respectivamente) e entre o ΔAVccPré-AVscPós e aindex (teste de Pearson, p<0,05; r=0,48). A variável que teve maior número de correlações significantes foi w21, que se correlacionou negativamente com ΔK2, ΔK1, ΔCKI e ΔKMáx (teste de Spearman, p<0,05; r=-0,56; -0,55; -0,51 e -0,47) respectiv...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.