In this study, using a coil stent, both IVUS and coronary pressure measurement were of similar value with respect to the assessment of optimum stent deployment. Therefore, coronary pressure measurement can be used as a cheap and rapid alternative to IVUS for that purpose.
The aim of the study was to compare acute and long-term angiographic and clinical outcome of balloon angioplasty and elective stenting in de novo lesions in the body of a saphenous vein graft (SVG). A total of 150 patients, with de novo lesions in SVG, were randomly assigned to balloon angioplasty or elective Wiktor I stent implantation. The angiographic restenosis rate at 6-month follow-up was 32.8% in the balloon group and 19.1% in the stent group (P = 0.069). At 1-year follow-up, target vessel revascularization rate was 31.4% vs. 14.5% (P < 0.05), and event-free survival was 60.0% vs. 76.3% (P < 0.05) for the balloon and stent group, respectively. Elective stent implantation in de novo SVG lesions is associated with a significant lower target vessel revascularization rate and a significant higher event-free survival at 1-year follow-up as compared to balloon angioplasty.
The hemocompatibility and biocompatibility of a stent are determined by the physical and electrochemical properties of the stent surface. The aim of this study was to determine the feasibility, safety and efficacy of implantation of a stent coated with silicon carbide. Baseline characteristics were collected prospectively. The occurrence of cardiac adverse events and the angina score were assessed at clinical follow-up. A total of 193 Tensum stents were implanted in 174 patients. In hospital, one patient experienced stent thrombosis and in 6% of the patients a creatinine kinase elevation to 240 U/l or more occurred. Long-term follow-up was performed in 172 patients, with a mean follow-up of 454 +/- 181 days. Ninety-seven per cent were still alive, 15% had undergone target-vessel revascularization, and 2% had angiographic restenosis and were treated with medication only. Seventy-one per cent of the patients were free of anginal complaints, and 20% had anginal complaints in Canadian Cardiac Society class I or II. The Tensum coronary stent showed to be a safe and efficacious device in this study, with a high primary success rate and favorable long-term clinical followup.
In this case report the occurrence of a catheter-induced coronary artery dissection is described. In our patient, angiography showed a mushroom-shaped exudate above the left main coronary artery. Intravascular ultrasound revealed a circular dissection with a huge false lumen connected to the true lumen by a small intimal tear. A brief review of the literature on catheter-induced coronary dissection is included. We believe that this case report provides a good illustration of the need for careful reviewing of indications for angiography. Although procedural risks are low, angiography remains an invasive diagnostic test with the potential to cause severe complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.