This work summarizes the electrochemical response of flavanone carbon composite electrodes in comparison with Nafion ® -coated flavanone carbon composite electrodes, for use as voltammetric pH sensors in both buffered and low-buffered media. Square wave voltammetric measurements suggest the peak potential achieved from the electrochemical polymerization after the electron-proton oxidation responds with accuracy to buffered pH solutions for both coated and non-coated electrodes, with a potential shift of 55.1 mV and 54.6 mV per pH unit respectively. However, a considerable improvement in stability, accuracy and sensitivity is provided by the proton-transfer Nafion ® layer in CO 2 bubbled sea water. Furthermore, Nafion ® -coated flavanone carbon composite electrodes predicted a pH of 8.04 for the commercial seawater, which is in excellent agreement with the measured pH 8.05 value.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.