In this retrospective study, removal of oesophageal foreign bodies either by oesophagoscopy or oesophagotomy had a similar outcome.
A penetrating injury, more than three radiographic lesions, or both together seemed to be indicative of the need for a thoracotomy. In the absence of these criteria, systematic bite wound explorative surgery is recommended, with extension to thoracotomy if thoracic body wall disruption is observed.
OBJECTIVE To compare the complication rates and outcomes in cats with ureteral obstruction treated by placement of double-pigtail ureteral stents or ureteral bypass (UB) devices. DESIGN Retrospective cohort study. ANIMALS Cats with unilateral or bilateral ureterolithiasis that received double-pigtail ureteral stents (30 stents in 27 cats; stent group) or UB devices (30 devices in 23 cats; UB group). PROCEDURES Medical records were reviewed to collect data on signalment, clinical signs, serum biochemical data, surgical procedure, duration of hospitalization, complications, and follow-up (≥ 6 months after placement) information. Outcomes were compared between device types. RESULTS Median durations of surgery and hospitalization were significantly longer in the stent versus UB group. Perioperative mortality rate was 18% (5/27) in the stent group and 13% (3/23) in the UB group. Median survival time was shorter in the stent versus UB group. Stent placement was associated with a greater risk of lower urinary tract-related signs, such as hematuria (52% [14/27]) and pollakiuria or stranguria (48% [13/27]). The risk of device occlusion was also greater in the stent (26% [7/27]) versus UB (4% [1/23]) group. The percentage of cats requiring additional procedures to treat complications was greater in the stent (44%; complications included uroabdomen, stent occlusion, and refractory cystitis) versus UB (9%; complications included UB occlusion and urethral obstruction) group. CONCLUSIONS AND CLINICAL RELEVANCE Although the benefits of stent placement in the treatment of ureteral obstruction in cats have been established, results suggested that cats treated with UB devices had a lower risk of complications and a longer survival time than those treated with double-pigtail ureteral stents.
A young female cat was presented with a protrusion of the uterus through the vulvar lips. The cat had a history of recent parturition, with delivery without incident of three kittens 48 h earlier. No fetus was found in the uterus. The protruding uterus was amputated and a staged ovariohysterectomy was performed. The day after surgery, the queen was healthy with no evidence of vulvar discharge. Two months later, the owner reported that the queen was clinically normal with no recurrence of clinical signs.
The objective of this study was to describe the operative technique and outcome of a simplified laparoscopic gastropexy approach in dogs. Twenty-one dogs undergoing prophylactic laparoscopic gastropexy with a simple continuous barbed suture without incising the seromuscular layer of the stomach and transversus abdominis muscle were reviewed. In 20 cases, additional procedures were performed (18 ovariectomies and 2 prescrotal castrations); 1 dog had two prior episodes of gastric dilation without volvulus and underwent gastropexy with a prophylactic intent. The gastropexy procedure had a median duration of 33 min (range 19-43 min). V-Loc 180 absorbable and the V-Loc PBT nonabsorbable suturing devices were used in 8 and 13 dogs, respectively. Minor intraoperative complications occurred in four cases: broken suture (1), needle dislodgement (2), and folded needle (1). Minor complications included self-limiting wound complications (3), abdominal discomfort (2), vomiting (1), and inappetence (2). Postoperative abdominal ultrasound performed after a median of 8 mo (6-36 mo) confirmed permanent adhesion at the gastropexy site in all dogs. One dog developed a fistula(1 yr postoperatively) and another a granuloma (3 mo postoperatively), both at the gastropexy site. Prophylactic laparoscopic gastropexy may be performed with knotless unidirectional barbed suture without creating an incision on the abdominal wall and stomach.
BackgroundSince their discovery by Karl Langer in the 19th Century, Skin Tension Lines (STLs) have been used by surgeons to decide the location and orientation of an incision. Although these lines are patient-specific, most surgeons rely on generic maps to determine their orientation. Beyond the imprecise pinch test, there remains no accepted method for determining STLs in vivo.Methods (i) The speed of an elastic motion travelling radially on the skin of canine cadavers was measured with a commercial device called the Reviscometer R .(ii) Similar to the original experiments conducted by Karl Langer, circular excisions were made on the skin and the geometric changes to the resulting wounds and excised samples were used to determine the orientation of STLs. ResultsA marked anisotropy in the speed of the elastic wave travelling radially was observed. The orientation of the fastest wave was found to correlate with the orientation of the elongated wound (P < 0.001, R 2 = 74%). Similarly, the orientation of fastest wave was the same for both in vivo and excised isolated samples, indicating that the STLs have a structural basis. Resulting wounds expanded by an average area of 9% (+16% along STL and −10% across) while excised skin shrunk by an average area of 33% (23% along STL and 10% across). ConclusionElastic surface wave propagation has been validated experimentally as a robust method for determining the orientation of STLs non-destructively and non-invasively. This study has implications for the identification of STLs and for the prediction of skin tension levels, both important factors in both human and veterinary reconstructive surgery.
Case summaryCranial ventral midline hernias, most often congenital, can be associated with other congenital abnormalities, such as sternal, diaphragmatic or cardiac malformations. A 4-year-old multiparous queen with a substernal hernia was admitted for evaluation of a mammary mass. During CT examination, a bifid sternum, the abdominal hernia containing the intestines, spleen, omentum, three fetuses, a mammary mass and an incidental peritoneopericardial diaphragmatic hernia were identified. Surgery consisted of a standard ovariohysterectomy and repair of the peritoneopericardial hernia. Primary closure of the abdominal hernia was attempted but deemed impossible even after the ovariohysterectomy, splenectomy and a partial omentectomy. An external abdominal oblique muscle flap was used to close with no tension on the cranial part of the hernia. One month postoperatively, the queen had no respiratory abnormalities and the herniorrhaphy was fully healed.Relevance and novel informationThis case is the first description of a 4-year-old multiparous pregnant queen with complex congenital malformations and surgical correction of a peritoneopericardial hernia and a 6 × 8 cmsubsternal hernia with an external abdominal oblique muscle flap. Life-threatening sequelae associated with large abdominal hernias can be attributed to space-occupying effects known as loss of domain and compartment syndrome, which is why a muscle flap was used in this case. The sternal cleft was not repaired because of the size of the cleft and the age of the cat.
The reconstruction of critical-size bone defects in long bones remains a challenge for clinicians. We developed a new bioactive medical device for long bone repair by combining a 3D-printed architectured cylindrical scaffold made of clinical-grade polylactic acid (PLA) with a polyelectrolyte film coating delivering the osteogenic bone morphogenetic protein 2 (BMP-2). This film-coated scaffold was used to repair a sheep metatarsal 25-mm long critical-size bone defect. In vitro and in vivo biocompatibility of the film-coated PLA material were proved according to ISO standards. Scaffold geometry was found to influence BMP-2 incorporation. Bone regeneration was followed using X-ray scans, microCT scans, and histology . We showed that scaffold internal geometry, notably pore shape, influenced bone regeneration, which was homogenous longitudinally. Scaffolds with cubic pores of about 870 micrometers and a low BMP-2 dose of about 120 microg/cm3 induced the best bone regeneration without any adverse effects. The visual score given by clinicians during animal follow-up was found to be an easy way to predict bone regeneration. This work opens perspectives for a clinical application in personalized bone regeneration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.