Purpose The ability to predict corneal edema and understand its relationship with imaging parameters enables optimization of decision-making in terms of cataract surgery. Therefore, we aimed to elucidate the immediate tomographic alterations after phacoemulsification. Patients and Methods In this prospective study, we evaluated clinical and corneal tomographic data of 30 patients with cataracts, obtained using a rotating Scheimpflug tomographic system before and after cataract surgery with a phacoemulsification system. Corneal thickness and volume were measured, and Pentacam Nucleus Staging, keratometry, and specular microscopy were performed preoperatively and immediately postoperatively. The Wilcoxon signed-rank test was used to compare pre-and postoperative values. We calculated the correlations between the changes in these values and multiple parameters related to phacodynamics, including “ultrasound (US) elapsed” (phaco time), “US average” (average power used), and “US absolute” (energy effectively dissipated, a product of the other two parameters). Results There were increases in corneal volume (p<0.0001) and pachymetry (p<0.0001), and a decrease in endothelial cell count (p<0.0001) after surgery. The mean differences in pre- and postoperative specular microscopy, corneal volume, and pachymetry were −335.13±236.21 cells/mm 3 , 1.33±0.56 mm 3 , and 61.33±23.73 microns, respectively. The difference in pre-and postoperative corneal volume in patients with US elapsed ≥40 s was 0.75 mm 3 greater than that in patients with US elapsed <40 s (95% confidence interval [CI]: 0.24–1.25; p=0.005); that of pachymetry in patients with US elapsed ≥40 s was 31.76 microns greater than that in patients with US elapsed <40 s (95% CI: 9.55–53.97; p=0.007). Spearman correlation revealed that, for every 1% increase in cataract density, the US average value increased by 0.31% (coef.: 0.3110; 95% CI: 0.0741–0.5490; p=0.012). Conclusion Knowledge of Pentacam Nucleus Staging and the effect of US elapsed on differences in corneal volume and pachymetry before and after cataract surgery should be of particular value for surgeons who routinely encounter patients with hard cataracts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.