Objective To evaluate the bi‐planar robot navigation system for insertion of cannulated screws in femoral neck fractures. Method Between January 2016 and December 2016, 60 patients with femoral neck fractures were separately treated using percutaneous cannulated screws assisted by the bi‐planar robot navigation system (robot group) and conventional freehand surgery (freehand group). The fluoroscopy time, the number of drilling attempts, and the operation time were recorded during operations; the dispersion and parallelism of the cannulated screws on the posteroanterior and lateral images were measured after operations. Patients were followed up for 12–24 months and the Harris scores and the final results of the two groups were compared. Results During bi‐planar robot navigation system‐assisted surgery, the fluoroscopy time for acquisition of images was 2.3 seconds on average, and the time for planning screws during the operation was 2.8 min on average. The average fluoroscopy time during the placement of the guide pin was 5.7 seconds and 14.14 seconds (P = 0.00), respectively. The average time of the placement of the cannulated screws was 12.7 min and 19.4 min (P = 0.00), respectively, in the robot group and the freehand group. In the robot group, only one guide pin was replaced during the operation, and the average number of adjustments for each guide pin was 2.39 in the freehand group. The screw parallelism and dispersion measured by postoperative imaging in the robot group were significantly superior to those in the freehand group. From postoperative CT it was evident that there were 5 cases of screws exiting the posterior cortex in both groups. During the follow‐up phase, 1 case of femoral head necrosis and 5 cases of femoral neck shortening of more than 10 mm occurred in the robotic navigation group; 3 cases of femoral head necrosis, 1 case of fracture nonunion, and 2 cases of shortening of more than 10 mm occurred in the freehand group. At 18 months after surgery, the average Harris scores of the patients were 85.20 and 83.45, respectively, with no significant difference. Conclusion Using bi‐planar robot navigation system‐assisted placement of femoral neck cannulated screws can significantly reduce the time of intraoperative fluoroscopy, drilling attempts, and operation time. The placed screws are superior to the screws placed freehand in relation to parallelism and dispersion. However, it is still necessary for surgeons to have a good reduction of the femoral neck fracture before surgery and to be proficient in the operation of the robot navigation system. In summary, the bi‐planar robot navigation system is an effective assistant instrument for surgery.
Background:Old pelvis fractures are among the most challenging fractures to treat because of their complex anatomy, difficult-to-access surgical sites, and the relatively low incidence of such cases. Proper evaluation and surgical planning are necessary to achieve the pelvic ring symmetry and stable fixation of the fracture. The goal of this study was to assess the use of three-dimensional (3D) printing techniques for surgical management of old pelvic fractures.Methods:First, 16 dried human cadaveric pelvises were used to confirm the anatomical accuracy of the 3D models printed based on radiographic data. Next, nine clinical cases between January 2009 and April 2013 were used to evaluate the surgical reconstruction based on the 3D printed models. The pelvic injuries were all type C, and the average time from injury to reconstruction was 11 weeks (range: 8–17 weeks). The workflow consisted of: (1) Printing patient-specific bone models based on preoperative computed tomography (CT) scans, (2) virtual fracture reduction using the printed 3D anatomic template, (3) virtual fracture fixation using Kirschner wires, and (4) preoperatively measuring the osteotomy and implant position relative to landmarks using the virtually defined deformation. These models aided communication between surgical team members during the procedure. This technique was validated by comparing the preoperative planning to the intraoperative procedure.Results:The accuracy of the 3D printed models was within specification. Production of a model from standard CT DICOM data took 7 hours (range: 6–9 hours). Preoperative planning using the 3D printed models was feasible in all cases. Good correlation was found between the preoperative planning and postoperative follow-up X-ray in all nine cases. The patients were followed for 3–29 months (median: 5 months). The fracture healing time was 9–17 weeks (mean: 10 weeks). No delayed incision healing, wound infection, or nonunions occurred. The results were excellent in two cases, good in five, and poor in two based on the Majeed score.Conclusions:The 3D printing planning technique for pelvic surgery was successfully integrated into a clinical workflow to improve patient-specific preoperative planning by providing a visual and haptic model of the injury and allowing patient-specific adaptation of each osteosynthesis implant to the virtually reduced pelvis.
Thin patches with ultralow velocities have been proposed to exist at the core‐mantle boundary (CMB). The detection and mapping of ultralow velocity zones (ULVZs) are difficult, in part, because of limited source‐receiver geometries of seismic phases used in ULVZ modeling. Here we develop a new approach that simultaneously utilizes ScS precursor and postcursor energies to investigate the CMB region for ULVZ structure. We stacked source‐deconvolved ScS waveforms within 1.5° geographic bins to extract ScS precursor and postcursor energies, if present, with ScS effectively removed from waveforms. We investigate the CMB beneath the central Pacific Ocean, and evidence for ULVZs is clearly apparent. Geographic bin stacks possessing similar ScS precursor‐plus‐postcursor behavior are grouped by using cluster analysis to produce more robust waveforms by enhancing the signal‐to‐noise ratios. Synthetic seismograms that demonstrate the amplitude and timing of the ULVZ arrivals are sensitive to ULVZ thickness and internal velocities. To pursue local ULVZ properties we processed 13,850 1‐D synthetic models with various ULVZ thicknesses and internal properties, using the identical ScS‐stripping method as with the data. A best fitting model was found for each geographical bin cluster by using an amplitude‐sensitive cross‐correlation algorithm. While limitations exist due to 1‐D modeling, strong lateral variations are clearly apparent in ULVZ thickness and properties across the large low shear velocity province (LLSVP) margin in our study area. Inside hypothesized LLSVP edges, ULVZs appear to distribute unevenly, suggesting 3‐D variations of convection currents.
Nearly antipodal continent-sized zones of reduced seismic shear wave velocities exist at the base of Earth's mantle, one beneath the Pacific Ocean, the other beneath the South Atlantic Ocean and Africa. Geophysicists have attributed the low velocity zones to elevated temperatures associated with large-scale mantle convection processes, specifically, hot mantle upwelling in response to cooler subduction-related downwelling currents. Hypotheses have included superplumes, isochemical heterogeneity, and stable as well as metastable basal thermochemical piles. Here we analyze waveform broadening and travel times of S waves from 11 deep focus earthquakes in the southwest Pacific recorded in North America, resulting in 8500 seismograms studied that sample the deep mantle beneath the Pacific. Waveform broadening is referenced to a mean S-wave shape constructed for each event, to define a relative-misfit‖. Large misfits are consistent with multipathing that can broaden wave pulses. Misfits of deep mantle sampling S-waves infer that the structure in the northeast
Pelvic acetabular fracture is a common kind of fracture, mostly caused by high energy injuries. It is associated with high mortality and disability rates. The aim of surgical treatment of pelvic acetabular fractures is to restore the symmetry and stability of the pelvic ring structure and the anatomical structure of acetabular. Open reduction internal fixation is often used for the treatment of such fractures, but open surgery is in cases of serious injury, more bleeding, and high risk of infection. With the development of minimally invasive technology and the concept of the bone channel structure, the percutaneous lag screw technique for the treatment of pelvic and acetabular fractures has been applied in clinical practice and has proven to be effective. However, the anatomical structure of the pelvis and acetabulum is complex, and there are many important nerves and vessels adjacent to it. Traditional fluoroscopy screw placement is prone to screw malposition, and even minor angle changes may lead to screw perforation and damage of nerve vessels. The problem of radiation exposure is also noteworthy. Robotic‐assisted surgery can be used to carry out screw position planning through preoperative imaging, intraoperative real‐time tracking, and mechanical arm assistance to ensure that the screw placement position is consistent with the planning. In this way, robotic‐assisted surgery can be used to accurately insert lag screws, and can reduce surgical risk and radiation exposure. This guide uses the TiRobot system as an example to describe the application of robot surgery in detail, aiming at standardizing the application of robots in orthopaedic surgery.
Objectives: To assess the efficiency, safety, and accuracy of S 2 (IS) screw fixation using a robot-assisted method compared with a freehand method.Methods: This is a retrospective clinical study. We analyzed the patients treated with S 2 IS screw fixation for unstable pelvic fractures from January 2016 to January 2019 in our institution. Sixty-three patients (17 men and 46 women) aged between 21 and 55 years (with an average age of 39.22 AE 9.28) were included in this study. According to the Tile classification, there were 26 (41.3%) type B fractures and 37 (58.7%) type C fractures. All patients were divided into robot-assisted (RA) group (38 patients) or the traditional freehand (FH) group (25 patients). In RA group, the S 2 IS screws were implanted with a robot-assisted technique. And S 2 IS screws were implanted with a traditional freehand technique in FH group. The screw-related complications were recorded during and after the surgery. The position of all screws and fracture reduction was assessed by postoperative CT scans according to the Gras classification. The number of guide wire attempts and the radiation exposure for S 2 screw implantation during operation were also recorded. Finally, the Matta standard was used to evaluate the fracture reduction of the IS joint.Results: A total of 89 IS screws were implanted into S2 iliosacral joint. Fifty-four screws were placed by RA (38 patients) and 35 screws were by FH (25 patients). There was no difference between the two groups with respect to demographic data. There was no screw-related complications or revision surgery in any group. In terms of screw placement, the excellent and good rate was 100% in the RA group, better than that in the FH group where it was only 85.7% (P < 0.001). The fluoroscopy time was 8.06 AE 3.54 s in RA group, which was much less than that in the FH group (27.37 AE 8.82 s, P < 0.001). The guide wire attempts in the RA group (0.685 AE 0.820) were much less than those in the FH group (5.77 AE 3.34) (P < 0.001). Both the fluoroscopy time per screw and the number of guide wire attempts in the RA group were much less than those in the FH group (P < 0.001). The overall postoperative excellent and good rate of Matta standard in RA and FH groups were 86.8% (34/4) and 90.0% (23/25), respectively (P = 0.750), and there was no statistical difference. Conclusion:The robot-assisted surgery is an accurate and minimally invasive technique. S 2 IS screw implantation assisted by TiRobot to treat the posterior pelvic ring fractures, have a high success rate than the freehand technique. Percutaneous RA S 2 IS screw fixation for unstable posterior pelvic ring injuries is safe and clinically feasible and has great clinical application value.
Introduction Pelvic fracture is a severe high-energy injury with the highest disability and mortality of all fractures. Traditional open surgery is associated with extensive soft tissue damages and many complications. Minimally invasive surgery potentially mitigates the risks of open surgical procedures and is becoming a new standard for pelvic fracture treatment. The accurate reduction has been recognized as the cornerstone of minimally invasive surgery for pelvic fracture. At present, the closed reduction in pelvic fractures is limited by the current sub-optimal 2D intra-operative imaging (fluoroscopy) and by the high forces of soft tissue involved in the fragment manipulation, which might result in fracture malreduction. To overcome these shortcomings and facilitate pelvic fracture reduction, we developed an intelligent robot-assisted fracture reduction (RAFR) system for pelvic fracture. Methods The presented method is divided into three parts. The first part is the preparation of 20 pelvic fracture models. In the second part, we offer an automatic reduction algorithm of our robotic reduction system, including Intraoperative real-time 3D navigation, reduction path planning, control and fixation, and robotic-assisted fracture reduction. In the third part, image registration accuracy and fracture reduction accuracy were calculated and analyzed. Results All 20 pelvic fracture bone models were reduced by the RAFR system; the mean registration error E1 of the 20 models was 1.29 ± 0.57 mm. The mean reduction error E2 of the 20 models was 2.72 ± 0.82 mm. The global error analysis of registration and reduction results showed that higher errors are mainly located at the edge of the pelvis, such as the iliac wing. Conclusion The accuracy of image registration error and fracture reduction error in our study was excellent, which could reach the requirements of the clinical environment. Our study demonstrated the precision and effectiveness of our RAFR system and its applicability and usability in clinical practice, thus paving the way toward robot minimally invasive pelvic fracture surgeries.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.