Twisted and coiled polymer (TCP) can generate large stroke and output high power density, making it a promising artificial muscle. Thermally induced muscles fabricated from nylon or other polymer fibers can be used in robotic, biomedical devices, and energy-harvesting equipment. While fibers with different shapes and materials have different optimal process parameters. Understanding mechanisms of TCP forming and the impact of process parameters is critical to explore stronger, more powerful artificial muscles. In this paper, an elastic-rod-theory-based model was established for capturing the quantitative relationship between tensile actuation and fabrication load. Further experimental results agree with model calculation and TCP muscles used in our research reaches maximum stroke of 52.6%, strain up to 9.8 MPa, and power density of 211.89 J/kg.
Twisted and coiled polymer (TCP) actuators are becoming increasingly prevalent in soft robotic fields due to their powerful and hysteresis-free stroke, large specific work density, and ease of fabrication. This paper presents a soft crawling robot with spike-inspired robot feet which can deform and crawl like an inchworm. The robot mainly consists of two leaf springs, connection part, robot feet, and two TCP actuators. A system level model of a soft crawling robot is presented for flexible and effective locomotion. Such a model can offer high-efficiency design and flexible locomotion of the crawling robot. Results show that the soft crawling robot can move at a speed of 0.275 mm/s when TCP is powered at 24 V.
Purpose Selective laser melting (SLM) enables the fabrication of lightweight and complex metallic structures. Support structures are required in the SLM process to successfully produce parts. Supports are typically lattice structures, which cost much time and material to manufacture. Besides, the manufacturability of these supports is undesirable, which may impact the quality of parts or even fail the process. The purpose of this paper is to investigate the efficiency and mechanical properties of advanced internal branch support structures for SLM. Design/methodology/approach The theoretic weight of a branch support and a lattice support of the same plane were calculated and compared. A group of standard candidates of branch support structures were manufactured by SLM. The weight and scanning time of specimens with different design parameters were compared. Then, these samples were tested using an MTS Insight 30 compression testing machine to study the influence of different support parameters on mechanical strength of the support structures. Findings The results show that branch type supports can save material, energy and time used needed for their construction. The yield strength of the branch increases with the branch diameter and inclined branch angle in general. Furthermore, branch supports have a higher strength than traditional lattice supports. Originality/value To the best of the authors’ knowledge, this is the first work investigating production efficiency and mechanical properties of branch support structures for SLM. The findings in this work are valuable for development of advanced optimal designs of efficient support structures for SLM process.
Twisted and coiled polymer (TCP) actuator has many advantages such as high contraction capability, high work density, low cost materials, and easiness of fabrication, making it promising for applications in biomedical devices, soft robotic, and energy-harvesting equipment. However, convenient and effective control of TCP actuators still remain some challenges. In this paper, we use an accurate straintemperature and force-temperature model of TCP actuators to design a simple and efficient closed-loop PID control system. The validity of the proposed controllers is investigated through numerical simulations and experiments. The results show good control performance with minimum tracking errors which is less than 3% in our work. Such accuracy is ideal for many engineering fields and robotic designs.
Abstract:The purpose of this paper is to present a new design method of lightweight parts fabricated by selective laser melting (SLM) based on the "Skin-Frame" and to explore the influence of fabrication defects on SLM parts with different sizes. Some standard lattice parts were designed according to the Chinese GB/T 1452-2005 standard and manufactured by SLM. Then these samples were tested in an MTS Insight 30 compression testing machine to study the trends of the yield process with different structure sizes. A set of standard cylinder samples were also designed according to the Chinese GB/T 228-2010 standard. These samples, which were made of iron-nickel alloy (IN718), were also processed by SLM, and then tested in the universal material testing machine INSTRON 1346 to obtain their tensile strength. Furthermore, a lightweight redesigned method was researched. Then some common parts such as a stopper and connecting plate were redesigned using this method. These redesigned parts were fabricated and some application tests have already been performed. The compression testing results show that when the minimum structure size is larger than 1.5 mm, the mechanical characteristics will hardly be affected by process defects. The cylinder parts were fractured by the universal material testing machine at about 1069.6 MPa. These redesigned parts worked well in application tests, with both the weight and fabrication time of these parts reduced more than 20%.
Twisted and coiled polymer (TCP) artificial muscles can exhibit unidirectional actuation similar to skeletal muscles. This paper presents a TCP driven artificial musculoskeletal actuation module that can be used in soft robots. This module can contract in the axis direction, and the contraction displacement and force can be controlled easily. The main body of the actuation module consists of TCP muscles and leaf springs, and the deformation of the module is actuated by the TCP muscles. A prototype was made to test the performance of the module. The design and experimental results of the module are presented. The module can provide contraction motion. Results show that the module can provide a contraction force of 0.7 N with displacement of approximately 6.8 mm at 120 ∘C when exposed to electrical power of 24 V. The proposed artificial musculoskeletal actuation module can potentially be applied in biomimetic robots and the aerospace field.
Background C5 nerve root paralysis is a nonnegligible complication after posterior cervical spine surgery (PCSS). The cause of its occurrence remains controversial. The purpose of this study was to analyse the incidence of and risk factors for C5 nerve root paralysis after posterior cervical decompression. Methods We retrospectively analysed the clinical data of 640 patients who underwent PCSS in the Department of Orthopaedics, Affiliated Hospital of Qingdao University from September 2013 to September 2019. According to the status of C5 nerve root paralysis after surgery, all patients were divided into paralysis and normal groups. Univariate and multivariate analyses were used to determine the independent risk factors for C5 nerve root paralysis. A receiver operating characteristic (ROC) curve was used to demonstrate the discrimination of all independent risk factors. Results Multivariate logistic regression analysis revealed that male sex, preoperative cervical spine curvature, posterior longitudinal ligament ossification, and preoperative C4/5 spinal cord hyperintensity were independent risk factors for paralysis, whereas the width of the intervertebral foramina was an independent protective factor for paralysis. The area under the curve (AUC) values of the T2 signal change at C4-C5, sex, cervical foramina width, curvature and posterior longitudinal ligament ossification were 0.706, 0.633, 0.617, 0.637, and 0.569, respectively. Conclusions Male patients with C4-C5 intervertebral foramina stenosis, preoperative C4-C5 spinal cord T2 high signal, combined with OPLL, and higher preoperative cervical spine curvature are more likely to develop C5 nerve root paralysis after surgery. Among the above five risk factors, T2 hyperintensity change in C4-C5 exhibits the highest correlation with C5 paralysis and strong diagnostic power. It seems necessary to inform patients who have had cervical spine T2 hyperintensity before surgery of C5 nerve root paralysis after surgery, especially those with altered spinal cord T2 signals in the C4-C5 segment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.