Hydroxyapatite has excellent biocompatibility and osteo-conductivity and, as the main inorganic component of human bones and teeth, is commonly used for bone repair. Its original characteristics can be changed by metal ion substitution. Cobalt ions can act as hypoxia-inducible factors and accelerate bone repair. At the same time, cobalt has paramagnetic properties and is often used in the study of medical imaging and target drugs. Through the introduction of cobalt ions, the unique hydroxyapatite has better biological activity and positioning of medical images. Herein, cobalt-substituted hydroxyapatite (CoHA) was synthesized on the surface of a titanium plate by electrochemical deposition and changes in the power output mode to explore the impact on CoHA. Electrochemical deposition with a pulse current significantly improved the productivity and uniformity of CoHA on the surface of titanium. CoHA show paramagnetic characteristics by a superconducting quantum interference device (SQUID). Resulting smaller particle size and circular morphology improves the magnetic strength of CoHA. Magnetic resonance imaging (MRI) of CoHA showed significant image contrast effect at low concentrations. The calculated particle relaxation rate was higher than other common MRI contrast agents. Biocompatibility of CoHA powder was evaluated using the human osteosarcoma cell line (MG63) which confirmed that CoHA is not cytotoxic and can promote cell growth and extracellular matrix mineralization. With the release of cobalt ions, CoHA was found to be significantly good in repression E. coli indicating about than 95% reduction in bacterial growth. The as-synthesized CoHA has a low degree of crystallinity, highly sensitive image contrast effect, and good bioactivity, and may have potential applications in bone repair and MRI.
In clinical dentistry practice, supplemental bone surgery or jawbone defect after tooth extraction must be assisted by a bone-filling material. Cobalt-substituted hydroxyapatite (COHA) effectively promotes bone cell growth, reduces the inflammatory response, and is an antibacterial agent. COHA can therefore be used as an alveolar bone-filling material or guided bone regeneration membrane. Meanwhile, COHA can be used in magnetic resonance imaging (MRI) with negative contrast agents and targeting materials without causing metal interference with the image. Hence, COHA has received increasing amounts of attention in recent years. However, the influence of different cobalt precursors on the synthesized COHA is still unknown. Therefore, COHA synthesized from 3 cobalt precursors (cobalt chloride, cobalt nitrate, and cobalt sulfate) was compared in this study. The results show that COHA synthesized by the precursor with the smallest anion radius, cobalt chloride, has a larger particle size (239 nm) and a higher cobalt ion substitution rate (15.6%). When the cobalt ion substitution rate increases, the MRI has a stronger contrast. Bioactivity data indicate that COHAC is more susceptible to degradation and therefore releases more cobalt ions to contribute to the differentiation of bone cells. Based on these studies, COHAC prepared with the cobalt chloride precursor has a higher cobalt ion substitution rate, faster degradation rate, better image contrast, and better bioactivity. It is therefore the preferred choice of bone-filling material for alveolar bone regeneration.
Quantitative evaluation using image biomarkers calculated from threshold-segmented lowattenuation areas on chest computed tomography (CT) images for diagnosing chronic obstructive pulmonary diseases (COPD) has been widely investigated. However, the segmentation results depend on the applied threshold and slice thickness of the CT images because of the partial volume effect (PVE). In this study, the air volume fraction (AV/TV) of lungs was calculated from CT images using a two-compartment model (TCM) for COPD diagnosis. A relative air volume histogram (RAVH) was constructed using the AV/TV values to describe the air content characteristics of lungs. In phantom studies, the TCM accurately calculated total cavity volumes and foam masses with percent errors of less than 8% and ±4%, respectively. In patient studies, the relative volumes of normal and damaged lung tissues and the damaged-to-normal RV ratio were defined and calculated from the RAVHs as image biomarkers, which correctly differentiated COPD patients from controls in 2.5-and 5mm-thick images with areas under receiver operating characteristic curves of >0.94. The AV/TV calculated using the TCM can prevent the effect of slice thickness, and the image biomarkers calculated from the RAVH are reliable for diagnosing COPD
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.