The response of single DNA molecules to externally applied forces and torques was directly measured using an angular optical trap. Upon overwinding, DNA buckled abruptly as revealed by a sharp extension drop followed by a torque plateau. When the DNA was held at the buckling transition, its extension hopped rapidly between two distinct states. Furthermore, the initial plectonemic loop absorbed approximately twice as much extension as was absorbed into the plectoneme upon each additional turn. The observed extension change after buckling and the postbuckling torque support a recent DNA elasticity model.The bending and torsional properties of DNA influence numerous cellular processes, notably DNA compaction, replication, transcription, and protein-DNA binding. DNA elasticity regulates how proteins bend and twist DNA upon binding and how translocating molecular motors exert torque and force on their DNA substrates. Single molecule techniques have proven to be powerful approaches for the investigation of the response of DNA to mechanical stress; individual DNA molecules can be stretched and twisted under physiologically relevant conditions. To date the stretching and bending elasticities of DNA have been well characterized through measurements of the force-extension relation of DNA [1,2]. However, somewhat less is known regarding the torsional elasticity of DNA, at least in part due to difficulties in making direct torque measurements. The most prevalent method to twist DNA is to use magnetic tweezers to rotate a magnetic bead via rotation of a magnetic field [3,4]. Twisting DNA can also be achieved by rotation of a micropipette cantilever [5]. These approaches have provided many important insights into DNA torsional properties even without torque detection. A recent and novel technique directly measured torque in DNA via viscous drag force on a small bead attached to the side of a DNA molecule [6]. This approach requires taut DNA to minimize writhe and thus is more suited for measurements under high force ( > 15 pN). More recently, an angular optical trap that we developed has permitted simultaneous and direct measurements of force and torque for concurrent observation of the tensile and torsional behaviors of DNA over broad ranges of forces and torques [7,8]. In addition, its wider bandwidth is well suited for detection of highly kinetic processes. Previously we showed that nanofabricated quartz cylinders are ideally suited as handles for angular trapping. During DNA supercoiling, the torque, angle, force, and extension of a DNA molecule can be simultaneously monitored at kHz rates. In this work, we have directly measured the torsional modulus of DNA in the intermediate force regime, determined basic relations regarding the dependence of torque on applied force, made the first observation of the abrupt formation of the initial plectoneme † Corresponding author. mwang@physics.cornell.edu. * Present address: Mayo Clinic, Rochester, Minnesota 55902, USA. (interwound loop) in positively supercoiled DNA, and mo...
We designed and created nanofabricated quartz cylinders well suited for torque application and detection in an angular optical trap. We made the cylinder axis perpendicular to the extraordinary axis of the quartz crystal and chemically functionalized only one end of each cylinder for attachment to a DNA molecule. We directly measured the torque on a single DNA molecule as it underwent a phase transition from B-form to supercoiled P-form.
We present measurements of the forces on, and displacements of, an optically trapped bead along the propagation direction of the trapping laser beam (the axial direction). In a typical experimental configuration, the bead is trapped in an aqueous solution using an oil-immersion, high-numerical-aperture objective. This refractive index mismatch complicates axial calibrations due to both a shift of the trap center along the axial direction and spherical aberrations. In this work, a known DNA template was unzipped along the axial direction and its characteristic unzipping force-extension data were used to determine 1), the location of the trap center along the axial direction; 2), the axial displacement of the bead from the trap center; and 3), the axial force exerted on the bead. These axial calibrations were obtained for trap center locations up to approximately 4 microm into the aqueous solution and with axial bead displacements up to approximately 600 nm from the trap center. In particular, the axial trap stiffness decreased substantially when the trap was located further into the aqueous solution. This approach, together with conventional lateral calibrations, results in a more versatile optical trapping instrument that is accurately calibrated in all three dimensions.
A total skin electron (TSE) floor technique is presented for treating patients who are unable to safely stand for extended durations. A customized flattening filter is used to eliminate the need for field junctioning, improve field uniformity, and reduce setup time. The flattening filter is constructed from copper and polycarbonate, fits into the linac's accessory slot, and is optimized to extend the useful height and width of the beam such that no field junctions are needed during treatment. A TSE floor with flattening filter (TSE FF) treatment course consisted of six patient positions: three supine and three prone. For all treatment fields, electron beam energy was 6 MeV; collimator settings were an x of 30 cm, y of 40 cm, and θcoll of 0°; and a 0.4 cm thick polycarbonate spoiler was positioned in front of the patient. Percent depth dose (PDD) and photon contamination for the TSE FF technique were compared with our standard technique, which is similar to the Stanford technique. Beam profiles were measured using radiochromic film, and dose uniformity was verified using an anthropomorphic radiological phantom. The TSE FF technique met field uniformity requirements specified by the American Association of Physicists in Medicine Task Group 30. TSE FF R80 ranges from 4 to 4.8 mm. TSE FF photon contamination was ~ 3%. Anthropomorphic radiological phantom verification demonstrated that dose to the entire skin surface was expected to be within about ±15% of the prescription dose, except for the perineum, scalp vertex, top of shoulder, and soles of the feet. The TSE floor technique presented herein eliminates field junctioning, is suitable for patients who cannot safely stand during treatment, and provides comparable quality and uniformity to the Stanford technique.PACS number: 87
Low dose rate (LDR) prostate brachytherapy is an evidence based radiation technique with excellent oncologic outcomes. By utilizing direct image guidance for radioactive source placement, LDR brachytherapy provides superior radiation dose escalation and conformality compared to external beam radiation therapy (EBRT). With this level of precision, late grade 3 or 4 genitourinary or gastrointestinal toxicity rates are typically between 1% and 4%. Furthermore, when performed as a same day surgical procedure, this technique provides a cost effective and convenient strategy. A large body of literature with robust follow-up has led multiple expert consensus groups to endorse the use of LDR brachytherapy as an appropriate management option for all risk groups of non-metastatic prostate cancer. LDR brachytherapy is often effective when delivered as a monotherapy, although for some patients with intermediate or high-risk disease, optimal outcome are achieved in combination with supplemental EBRT and/or androgen deprivation therapy (ADT). In addition to reviewing technical aspects and reported clinical outcomes of LDR prostate brachytherapy, this article will focus on the considerations related to appropriate patient selection and other aspects of its use in the treatment of prostate cancer.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.