Here we present a guide to ion mobility mass spectrometry experiments, which covers both linear and nonlinear methods: what is measured, how the measurements are done, and how to report the results, including the uncertainties of mobility and collision cross section values. The guide aims to clarify some possibly confusing concepts, and the reporting recommendations should help researchers, authors and reviewers to contribute comprehensive reports, so that the ion mobility data can be reused more confidently. Starting from the concept of the definition of the measurand, we emphasize that (i) mobility values ( K 0 ) depend intrinsically on ion structure, the nature of the bath gas, temperature, and E / N ; (ii) ion mobility does not measure molecular surfaces directly, but collision cross section (CCS) values are derived from mobility values using a physical model; (iii) methods relying on calibration are empirical (and thus may provide method‐dependent results) only if the gas nature, temperature or E / N cannot match those of the primary method. Our analysis highlights the urgency of a community effort toward establishing primary standards and reference materials for ion mobility, and provides recommendations to do so. © 2019 The Authors. Mass Spectrometry Reviews Published by Wiley Periodicals, Inc.
The mechanism of the multiple charging of macromolecules in electrospray ionization (ESI) continues to inspire debate and controversy. Recently, we proposed that the number of charges on a macromolecule is determined by the emission of small charge carriers from macromoleculecontaining nanodroplets and that, after solvent evaporation, the remaining charge is transferred to the macromolecule. In this study, we tested the applicability of this new theory for macromolecular, positive-ion ESI mass spectrometry by measuring the mean charge states and charge distributions of globular proteins under non-denaturing and denaturing conditions. Predictions of protein mean charge states for native state proteins are in excellent agreement with mass spectrometric measurements, giving strong credence to the proposed theory. Theoretical predictions are also in good agreement with mean charge states measured for proteins in basic solutions (pH = 11.5). For some proteins in acidic solutions (pH = 2.1), the measured mean charge states are anomalously higher than the Rayleigh limit of a water droplet with a volume equivalent to that of the protein. We propose that some macromolecules that are highly charged in solution may desorb from charged droplets of the same polarity in a similar manner to that whereby charge carriers emit from nanodroplets, leading to "supercharged" macromolecular ions. Examination of rate expressions for solvent evaporation and charge-carrier emission demonstrates that the newly proposed model for ESI is consistent with previously reported ion-emission kinetics. Overall, we obtained additional experimental evidence for the charge carrier emission model for macromolecular charging, suggesting opportunities for understanding and applying ESI-MS.
Aims:The aerosolization and collection of submicrometre and ultrafine virus particles were studied with the objective of developing robust and accurate methodologies to study airborne viruses. Methods and Results: The collection efficiencies of three sampling devices used to sample airborne biological particles -the All Glass Impinger 30, the SKC BioSamplerÒ and a frit bubbler -were evaluated for submicrometre and ultrafine virus particles. Test virus aerosol particles were produced by atomizing suspensions of single-stranded RNA and double-stranded DNA bacteriophages. Size distribution results show that the fraction of viruses present in typical aqueous virus suspensions is extremely low such that the presence of viruses has little effect on the particle size distribution of atomized suspensions. It has been found that none of the tested samplers are adequate in collecting submicrometre and ultrafine virus particles, with collection efficiencies for all samplers below 10% in the 30-100 nm size range. Plaque assays and particle counting measurements showed that all tested samplers have time-varying virus particle collection efficiencies. A method to determine the size distribution function of viable virus containing particles utilizing differential mobility selection was also developed. Conclusions: A combination of differential mobility analysis and traditional plaque assay techniques can be used to fully characterize airborne viruses. Significance and Impact of the Study: The data and methods presented here provide a fundamental basis for future studies of submicrometre and ultrafine airborne virus particles.
Ion/electrical mobility measurements of nanoparticles and polyatomic ions are typically linked to particle/ion physical properties through either application of the Stokes-Millikan relationship or comparison to mobilities predicted from polyatomic models, which assume that gas molecules scatter specularly and elastically from rigid structural models. However, there is a discrepancy between these approaches; when specular, elastic scattering models (i.e., elastic-hard-sphere scattering, EHSS) are applied to polyatomic models of nanometer-scale ions with finite-sized impinging gas molecules, predictions are in substantial disagreement with the Stokes-Millikan equation. To rectify this discrepancy, we developed and tested a new approach for mobility calculations using polyatomic models in which non-specular (diffuse) and inelastic gas-molecule scattering is considered. Two distinct semiempirical models of gas-molecule scattering from particle surfaces were considered. In the first, which has been traditionally invoked in the study of aerosol nanoparticles, 91% of collisions are diffuse and thermally accommodating, and 9% are specular and elastic. In the second, all collisions are considered to be diffuse and accommodating, but the average speed of the gas molecules reemitted from a particle surface is 8% lower than the mean thermal speed at the particle temperature. Both scattering models attempt to mimic exchange between translational, vibrational, and rotational modes of energy during collision, as would be expected during collision between a nonmonoatomic gas molecule and a nonfrozen particle surface. The mobility calculation procedure was applied considering both hard-sphere potentials between gas molecules and the atoms within a particle and the long-range ion-induced dipole (polarization) potential. Predictions were compared to previous measurements in air near room temperature of multiply charged poly(ethylene glycol) (PEG) ions, which range in morphology from compact to highly linear, and singly charged tetraalkylammonium cations. It was found that both non-specular, inelastic scattering rules lead to excellent agreement between predictions and experimental mobility measurements (within 5% of each other) and that polarization potentials must be considered to make correct predictions for high-mobility particles/ions. Conversely, traditional specular, elastic scattering models were found to substantially overestimate the mobilities of both types of ions.
Rationale: Aerosol generation with modes of oxygen therapy such as high-flow nasal cannula and noninvasive positive-pressure ventilation is a concern for healthcare workers during the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic. The amount of aerosol generation from the respiratory tract with these various oxygen modalities is unknown. Objectives: To measure the size and number concentration of particles and droplets generated from the respiratory tract of humans exposed to various oxygen delivery modalities. Methods: Ten healthy participants with no active pulmonary disease were enrolled. Oxygen modalities tested included nonhumidified nasal cannula, face mask, heated and humidified high-flow nasal cannula, and noninvasive positive-pressure ventilation. Aerosol generation was measured with each oxygen mode while participants performed maneuvers of normal breathing, talking, deep breathing, and coughing. Testing was conducted in a negative-pressure room. Particles with a diameter between 0.37 and 20 μm were measured using an aerodynamic particle spectrometer. Measurements and Main Results: Median particle concentration ranged from 0.041 to 0.168 particles/cm 3 . Median diameter ranged from 1.01 to 1.53 μm. Cough significantly increased the number of particles measured. Measured aerosol concentration did not significantly increase with the use of either humidified high-flow nasal cannula or noninvasive positive-pressure ventilation. This was the case during normal breathing, talking, deep breathing, and coughing. Conclusions: Oxygen delivery modalities of humidified high-flow nasal cannula and noninvasive positive-pressure ventilation do not increase aerosol generation from the respiratory tract in healthy human participants with no active pulmonary disease measured in a negative-pressure room.
A parallel-plate differential mobility analyzer and a time-of-flight mass spectrometer (DMA-MS) are used in series to measure true mobility in dry atmospheric pressure air for mass-resolved electrosprayed GroEL tetradecamers (14-mers; ~800 kDa). Narrow mobility peaks are found (2.6-2.9% fwhm); hence, precise mobilities can be obtained for these ions without collisional activation, just following their generation by electrospray ionization. In contrast to previous studies, two conformers are found with mobilities (Z) differing by ~5% at charge state z ~ 79. By extrapolating to small z, a common mobility/charge ratio Z(0)/z = 0.0117 cm(2) V(-1) s(-1) is found for both conformers. When interpreted as if the GroEL ion surface were smooth and the gas molecule-protein collisions were perfectly elastic and specular, this mobility yields an experimental collision cross section, Ω, 11% smaller than in an earlier measurement, and close to the cross section, A(C,crystal), expected for the crystal structure (determined by a geometric approximation). However, the similarity between Ω and A(C,crystal) does not imply a coincidence between the native and gas-phase structures. The nonideal nature of protein-gas molecule collisions introduces a drag enhancement factor, ξ = 1.36, with which the true cross section A(C) is related to Ω via A(C) = Ω/ξ. Therefore, A(C) for GroEL 14-mer ions determined by DMA measurements is 0.69A(C,crystal). The factor 1.36 used here is based on the experimental Stokes-Millikan equation, as well as on prior and new numerical modeling accounting for multiple scattering events via exact hard-sphere scattering calculations. Therefore, we conclude that the gas-phase structure of the GroEL complex as electrosprayed is substantially more compact than the corresponding X-ray crystal structure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.