Despite the previously reported "within stroll" variability of walking bouts for distances, speeds, and stop durations, GPS derived greatest distance and average speed are reliable in PAD patients in test-retest experiments. The GPS appears to be a new tool to assess walking limitation and allows objective clinical investigation.
Background: Exercise transcutaneous oximetry (Ex-tcPO2) is a non-invasive test for exercise-induced buttock ischemia. Prior study defined Ex-tcPO2 normal/abnormal cut-offs against arteriography but no external validation was available. The aims of this study were therefore to (1) determine the diagnostic performance of Ex-tcPO2 against CTA; (2) determine the cut-off point for detection of stenosis >75% in arteries toward the hypogastric circulation; and (3) determine the effect of chest profile classification on the diagnostic performance of Ex-tcPO2.
Methods and Results:A total of 207 patients referred for Ex-tcPO2 were analyzed. DROP during Ex-tcPO2 was compared with the CTA results. Chest-tcPO2 changes were automatically classified into pre-defined profiles representing normal or abnormal responses. Using DROP <−15 mmHg as a cut-off, Ex-tcPO2 had 80.2% sensitivity, 72.3% specificity, 43.1% PPV, 93.3% NPV and 73.9% accuracy, to detect 1 stenosis >75% in arteries toward the hypogastric circulation. Optimal DROP to detect stenosis was: −15 mmHg. The overall diagnostic performance of Ex-tcPO2 was independent of chest profile classification.
Conclusions:Ex-tcPO2 has satisfactory diagnostic performance to detect arterial stenoses towards the hypogastric circulation. Abnormal chest-tcPO2 profile does not impair the overall diagnostic performance of the test.
Ex-tcpO2 is negative in more than 20% of tests performed in patients with an ABI under 0.90 and a history of calf claudication. In most cases, when excluding re-tests and non-limiting or non-calf claudication on the treadmill, non-calf ischemia or a non-vascular limitation occurring during the test were observed. This observation supports both the value of treadmill testing in patients with calf claudication assumed to be of arterial origin (ABI<0.90) and the use of Ex-tcpO2 to detect non-calf ischemia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.