Indoor allergens are among the main causes of allergic rhinitis and asthma. Allergen exposure is not limited to private homes. Mite, cat, and dog allergens were measured in day care centers to determine whether these concentrations detected might exert significant influence on human health. In 20 day care centers across North Rhine-Westphalia, Germany, the surfaces of 171 rooms were vacuumed 4 times a year to collect dust (1340 samples in total). In all samples, domestic mite antigens (DM) and the main allergens of cats (Fel d 1) and dogs (Can f 1) were quantified using enzyme immunoassays. Provisional threshold limits (PTL) for increased risks of sensitization and allergic symptoms were estimated according to published values and conversion factors. The influence of room characteristics on allergen concentrations was analyzed in mixed linear models, also considering values below the limit of detection (LOD). Nearly all samples contained allergens (99% DM, 96% Fel d 1, and 96% Can f 1). The concentrations rarely exceeded levels that were previously found to induce symptoms in home environments, but were frequently higher than estimates for enhanced sensitization risk (13% DM, 43% Fel d 1, and 27% Can f 1). Upholstered furnishings had the highest dust and allergen loads, followed by carpets and smooth floors. Allergen concentrations on different surface types that were sampled in the same room at the same time were significantly correlated and analyzed in separate models. The highest DM concentrations were present in bedrooms and in autumn. Further, DM loads on floors decreased significantly in rooms that were renovated within the last 5 years. If there were no records that furnishings were vacuumed, there were then significantly higher Can f 1 loads. Sweeping floors elevated DM and cat allergen concentrations. In addition to mite allergens, cat and dog allergens were detected in nearly all samples from day care centers. Overall, the present results indicate that allergen concentrations may be reduced by renovation and appropriate cleaning procedures.
Mite, mouse, cat, and dog allergens were mostly higher in DCC than in homes. Exposure to dog and cat allergens in DCC often reached levels of households with pets.
Objectives Most studies on indoor allergen exposure used vacuumed surface samples for quantification. One alternative is electrostatic dust collectors (EDCs), which sample previously airborne settled dust. The aim of this study was to compare allergen quantification using two different sampling methods, with respect to repeatability, and to determine how well the results agree with one another. Methods Four times a year, measurements were made from samples that were either collected from the vacuuming of surfaces, or from EDCs, from 20 German day-care centers totaling 167 rooms. Overall, 504 vacuumed samples collected from smooth floors, 435 samples from carpets, 291 samples from upholstered furniture and beds, and 605 EDC samples were analyzed using six fluorescence enzyme immunoassays recognizing Fel d 1, Can f 1, Mus m 1, domestic mite (DM), Dermatophagoides pteronyssinus (Dp), and Tyrophagus putrescentiae (Tp) antigens. Variances and correlations among the repeat measurements over the course of the year within each sample type, and the correlations between surface samples and the corresponding EDC samples were calculated. Results Repeat measurements over the year correlated significantly with one another. However, only Fel d 1, Can f 1, and DM in the EDC samples; DM, Dp, Tp, and Fel d 1 in the upholstered furniture samples; and DM in the carpet samples show representative results of single measurements according to their variance ratios (within-room/between-room variance <1). The highest correlation between surface and EDC samples was found for Fel d 1 on the upholstered furniture (r 0.52), followed by Can f 1 on the upholstered furniture and Can f 1 on carpets (r 0.47 and 0.45, respectively). The maximum correlation for mite antigens was between carpet samples and EDC (DM r 0.27, Dp r 0.33). Mus m 1 and Tp antigens for the most part did not correlate to the EDC results. Conclusions Both vacuumed dust from upholstered furniture and EDC samples were suitable for repeatable quantification of several allergens in day-care centers within a year. However, there was little agreement among the different collection methods, especially for Mus m 1 and certain mite antigens. Therefore, the method and location used for collection may greatly influence allergen exposure assessment and study results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.