No abstract
To assess the potential influence of multifidus atrophy and fatty degeneration on the incidence of adjacent vertebral compression fractures within one year after the index fracture. In a retrospective cohort study, patients who underwent surgery for an OVCF were identified and baseline characteristics, fracture patterns and the occurrence of secondary adjacent fractures within one year were obtained by chart review. Multifidus muscle atrophy and fatty degeneration were determined on preoperative MRI or CT scans. In this analysis of 191 patients (mean age 77 years, SD 8, 116 female), OF type 3 was the most common type of OVCF (49.2%). Symptomatic adjacent OVCFs within one year after index fracture were observed in 23/191 patients (12%) at mean 12, SD 12 weeks (range 1–42 weeks) postoperatively. The mean multifidus muscle area was 264, SD 53 mm2 in patients with an adjacent vertebral fracture and 271, SD 92 mm2 in patients without a secondary fracture (p = 0.755). Mean multifidus fatty infiltration was graded Goutallier 2.2, SD 0.6 in patients with an adjacent fracture and Goutallier 2.2, SD 0.7 in patients without an adjacent fracture (p = 0.694). Pre-existing medication with corticosteroids was associated with the occurrence of an adjacent fracture (p = 0.006). Multifidus area and multifidus fatty infiltration had no significant effect on the occurrence of adjacent vertebral fractures within one year after the index fracture. Patients with a pre-existing medication with corticosteroids were more likely to sustain an adjacent fracture.
Background We report a patient who fractured the seventh cervical vertebra while playing a virtual reality (VR) game, without any other trauma. This case report aims to describe the spinal trauma incurred during the use of a VR headset in a video game. Case presentation The Caucasian patient presented with pain and swelling in the lower cervical spine at our clinic after playing a video game involving a combination of shoulder, arm and head movements while wearing a VR headset. Preexisting comorbidities were not present in the 31-year-old male. No history of regular medication use or drug abuse was recorded. After performing a clinical examination and radiological diagnostics, we found a dislocated traumatic fracture of the spinous process of the seventh cervical vertebra. After a soft tissue defect was excluded through magnetic resonance imaging (MRI) diagnostics, a conservative therapy regimen with pain therapy and immobilization was started. After hospitalization, outpatient controls were conducted at 4, 6 and 12 weeks. At 6 weeks after hospitalization, the patient had recovered from the injury without complications. Conclusions Rapid movements during VR gaming can lead to injuries of the cervical spine. In addition to rapid movements, the additional weight of the VR headset as well as the decoupling of audiovisual stimuli from the perceived proprioceptive information should be considered. Determining whether this is an isolated incident induced by unknown preexisting factors or whether the trauma mechanism alone can lead to severe spinal trauma needs to be studied further with additional cases.
Background Pedicle screw insertion in osteoporotic patients is challenging. Achieving more screw-cortical bone purchase and invasiveness minimization, the cortical bone trajectory and the midline cortical techniques represent alternatives to traditional pedicle screws. This study compares the fatigue behavior and fixation strength of the cement-augmented traditional trajectory (TT), the cortical bone trajectory (CBT), and the midline cortical (MC). Methods Ten human cadaveric spine specimens (L1 - L5) were examined. The average age was 86.3 ± 7.2 years. CT scans were provided for preoperative planning. CBT and MC were implanted by using the patient-specific 3D-printed placement guide (MySpine®, Medacta International), TT were implanted freehand. All ten cadaveric specimens were randomized to group A (CBT vs. MC) or group B (MC vs. TT). Each screw was loaded for 10,000 cycles. The failure criterion was doubling of the initial screw displacement resulting from the compressive force (60 N) at the first cycle, the stop criterion was a doubling of the initial screw displacement. After dynamic testing, screws were pulled out axially at 5 mm/min to determine their remaining fixation strength. Results The mean pull-out forces did not differ significantly. Concerning the fatigue performance, only one out of ten MC of group A failed prematurely due to loosening after 1500 cycles (L3). Five CBT already loosened during the first 500 cycles. The mean displacement was always lower in the MC. In group B, all TT showed no signs of failure or loosening. Three MC failed already after 26 cycles, 1510 cycles or 2144 cycles. The TT showed always a lower mean displacement. In the subsequent pull-out tests, the remaining mean fixation strength of the MC (449.6 ± 298.9 N) was slightly higher compared to the mean pull-out force of the CBT (401.2 ± 261.4 N). However, MC (714.5 ± 488.0 N) were inferior to TT (990.2 ± 451.9 N). Conclusion The current study demonstrated that cement-augmented TT have the best fatigue and pull-out characteristics in osteoporotic lumbar vertebrae, followed by the MC and CBT. MC represent a promising alternative in osteoporotic bone if cement augmentation should be avoided. Using the patient-specific placement guide contributes to the improvement of screws’ biomechanical properties.
Introduction Osteoporotic vertebral compression fractures (VCFs) are common. An increase in mortality associated with osteoporotic VCFs has been well documented. The purpose of this study was to assess the impact of time to surgery on 1-year survival in patients with osteoporotic vertebral compression fractures. Methods In a retrospective cohort study with prospective mortality follow-up, consecutive patients aged ≥ 60 years who had operative treatment of a low-energy fracture of a thoracolumbar vertebra and had undergone surgical stabilization between January 2015 and December 2018 were identified from our institutional database. By chart review, additional information on hospitalization time, comorbidities (expressed as ASA - American Society of Anesthesiologists Scale), complications and revision surgery was obtained. Time-to-surgery was defined as the time between admission and surgery. Mortality data was assessed by contacting the patients by phone, mail or the national social insurance database. Results Two hundred sixty patients (mean age 78 years, SD 7 years, range, 60 to 93; 172 female) were available for final analysis. Mean follow-up was 40 months (range, 12 to 68 months). Fifty-nine patients (22.7%) had died at final follow-up and 27/260 patients (10.4%) had died within 1 year after the surgery. Time-to-surgery was not different for patients who died within 1 year after the surgery and those who survived (p = .501). In-hospital complications were seen in 40/260 (15.4%) patients. Time-to-surgery showed a strong correlation with hospitalization time (Pearson’s r = .614, p < .001), but only a very weak correlation with the time spent in hospital after the surgery (Pearson’s r = .146, p = .018). Conclusions In contrast to patients with proximal femur factures, time-to-surgery had no significant effect on one-year mortality in geriatric patients with osteoporotic vertebral compression fractures. Treatment decisions for these fractures in the elderly should be individualized.
Background The presence of muscular deficiency seems to be a major cause of back pain that requires counteractions. Considering that the autochthonous back muscles, responsible for straightening and stabilizing the spine, cannot be activated voluntarily, they can be strengthened only through specific training. The computer-supported test and training system (CTT) Centaur (BfMC GmbH, Leipzig, SN, Germany) seems well suited for this purpose. To show its potential as a reliable diagnostic and training tool, this study aimed to evaluate the test-retest reliability of this 3D spatial rotation device. Methods A prospective pilot study was conducted in 20 healthy volunteers of both sexes. For test-retest reliability analysis, three measurements were performed with a two-day interval between each measurement. Each measurement consisted of a one-minute endurance test performed in eight different positions (transverse plane). During the test, the subject was tilted by 90° in the sagittal plane from a neutral, upright position. Meanwhile, the subject’s level of upper body stabilization along the body axis was assessed. All trunk movements (momentum values) were quantified by a multicomponent force sensor and standardized relative to the subject’s upper body mass. The range of motion was assessed by 95% confidence ellipse analysis. Here, all position-specific confidence ellipses for each measurement were merged to a summarized quantity. Finally, ICC analysis using a single-rating, absolute agreement, two-way mixed-effects model and a Bland-Altman plot was performed to determine the reliability. Results Considering all measurements (t1, t2, t3), the ICC for reliability evaluation was 0.805, and the corresponding 95% confidence interval (CI) was [0.643, 0.910]. Moreover, the Bland-Altman plots for all three pairs of time points did not show significant differences. Conclusion This study concludes that the CTT Centaur shows good test-retest reliability, indicating it can be used in clinical practice in the future.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.